Prity K1CPW8

Manwal tal-Utent tal-Prity K1CPW8 Cast Iron Stove bi Skambjatur tal-Ilma

Model: K1CPW8 | Brand: Prity

1. Introduzzjoni

This user manual provides essential information for the safe and efficient operation, installation, and maintenance of your Prity K1CPW8 cast iron wood-burning stove with an integrated water exchanger. Please read this manual thoroughly before installation and use.

1.1 Prodott Fuqview

The Prity K1CPW8 is a highly efficient wood-burning stove designed for heating living spaces and integrating with a central heating system via its built-in water exchanger. It features a durable cast iron construction, a ceramic heat-resistant glass in the combustion chamber, and a secondary door for convenience.

Prity K1CPW8 Cast Iron Stove with Water Exchanger

Figura 1: Quddiem view of the Prity K1CPW8 Cast Iron Stove, showing the combustion chamber with visible flames and the lower compartment.

1.2 Twissijiet ta' Sigurtà

2. Setup u Installazzjoni

Proper installation is crucial for the safe and efficient operation of your stove. It is highly recommended that installation be performed by a qualified professional.

2.1 Spakkjar u Spezzjoni

Carefully unpack the stove and inspect it for any damage that may have occurred during transit. Report any damage to your supplier immediately.

2.2 Post u awtorizzazzjonijiet

Choose a suitable location on a non-combustible floor. Ensure adequate clearance from walls, furniture, and other combustible materials. Refer to the technical specifications for exact minimum distances.

Prity K1CPW8 Stove installed in a living room

Figure 2: The Prity K1CPW8 stove positioned in a living room, demonstrating typical installation with a visible chimney pipe and wood storage.

2.3 Konnessjoni taċ-ċmieni

Connect the stove to a suitable, properly sized chimney flue. Ensure all connections are sealed and airtight to prevent smoke leakage and ensure proper draft. The chimney must be clean and free of obstructions.

Fuq view of Prity K1CPW8 stove with chimney connection

Figura 3: Fuq view of the Prity K1CPW8 stove, showing the circular opening for chimney connection and a removable cover for a cooking plate.

2.4 Water Exchanger Connection

The integrated water exchanger requires connection to your central heating system. This must be done by a certified plumber. Ensure the system includes an expansion tank, circulating pump, safety valve, and pressure gauge. Fill the system with water and bleed all air before operation.

Lura view of Prity K1CPW8 stove showing water connections

Figura 4: Wara view of the Prity K1CPW8 stove, highlighting the two pipe connections for the integrated water exchanger system.

3. Istruzzjonijiet Operattivi

3.1 Fuel Type

Only use dry, seasoned firewood. Wood moisture content should be 16% ± 4% according to EN 13240:2006. Do not use wet wood, treated wood, coal, or any other combustible materials not specified for this stove.

3.2 Tixgħel il-Fuklar

  1. Open the primary air intake fully.
  2. Place crumpled paper or firelighters at the bottom of the combustion chamber.
  3. Add a small amount of kindling on top of the paper/firelighters.
  4. Light the paper/firelighters.
  5. Once the kindling is burning well, gradually add larger pieces of dry firewood.
  6. Agħlaq il-bieb sew.

3.3 Kontroll tat-Temperatura

Adjust the primary and secondary air intakes to control the burn rate and heat output. Closing the air intakes will reduce the burn rate, while opening them will increase it. Avoid over-firing the stove, as this can damage the unit and lead to unsafe conditions.

Nota: The manufacturer recommends not overloading the stove with too much wood to avoid high temperatures at the boiler outlet, especially if not connected to a regulated system.

4. Manutenzjoni

Regular maintenance ensures the longevity and safe operation of your Prity K1CPW8 stove.

4.1 Tneħħija tal-Irmied

Remove ash regularly from the ash pan located below the cast iron grate. Do not allow ash to build up and block the air intake. Always ensure ashes are cold before disposal.

4.2 Tindif tal-Ħġieġ

The ceramic glass in the combustion chamber may accumulate soot. Clean it when the stove is cold using a specialized glass cleaner for wood stoves or a damp cloth dipped in ash. Avoid abrasive cleaners.

4.3 Tindif taċ-Ċumnija u l-Pajpijiet tal-Fluw

Have your chimney and flue pipes inspected and cleaned by a certified chimney sweep at least once a year, or more frequently depending on usage. This prevents creosote buildup, which can lead to chimney fires.

4.4 Spezzjoni Ġenerali

Periodically check all seals, gaskets, and connections for wear and tear. Replace any damaged parts immediately to maintain efficiency and safety.

5 Issolvi l-problemi

This section addresses common issues you might encounter with your stove.

ProblemaKawża PossibbliSoluzzjoni
Smoke entering the roomPoor chimney draft, blocked flue, downdraft, door not sealed.Check chimney for blockages, ensure proper ventilation, inspect door seals, pre-heat flue.
Stove not heating efficientlyWet wood, insufficient air supply, excessive ash buildup, chimney issues.Use dry wood, open air intakes, remove ash, check chimney.
Il-ħġieġ jiswed malajrWet wood, low burning temperature, insufficient air wash.Use dry wood, increase burn rate, ensure air wash vents are clear.
Water system not heatingAir in system, pump malfunction, insufficient heat from stove.Bleed air from system, check pump, ensure stove is burning at optimal temperature. Consult a plumber.

6. Speċifikazzjonijiet Tekniċi

Below are the key technical specifications for the Prity K1CPW8 stove.

AttributValur
BrandPrity
MudellK1CPW8
KulurGraphic Black
MaterjalĦadid fondut
Dimensjonijiet tal-Prodott (L x W x H)46 x 44 x 76 ċm
Piż tal-oġġett74 Kilogrammi (163.14 libbra)
Output tas-Sħana Nominali13.1 kW
Room Heating Output6.1 kW
Water Heating Output7.0 kW
Effiċjenza77.4% (High Efficiency)
Maximum Working Pressure (Water)1.25 bar
Tip ta 'ventilazzjoniVent Dirett
Assemblea MeħtieġaNru
Minimum Clearances (Rear)400 mm
Minimum Clearances (Side)400 mm
Minimum Clearances (Front)800 mm
Energy efficiency label for Prity K1W8 and K1CPW8 stoves, showing A energy class and heat outputs.

Figure 5: Energy efficiency label for Prity K1CPW8, indicating an A-class rating with 6.0 kW room heating and 7.0 kW water heating output.

Declaration of Performance for Prity K1CPW8 stove, detailing essential characteristics and performance values.

Figure 6: Declaration of Performance document for the Prity K1CPW8, outlining compliance with EU regulations and technical specifications.

7. Garanzija u Appoġġ

Għal informazzjoni dwar il-garanzija, jekk jogħġbok irreferi għat-termini u l-kundizzjonijiet ipprovduti mill-bejjiegħ tiegħek fil-ħin tax-xiri. Żomm il-prova tax-xiri tiegħek għal kwalunkwe talba ta' garanzija.

For technical support or spare parts inquiries, please contact your authorized Prity dealer or the manufacturer directly. While specific spare parts availability information is not always provided, your dealer should be able to assist with service and parts.

Product label with barcode and manufacturer details for Prity K1CPW8 stove.

Figure 7: Product label with barcode and manufacturer details, including "Prity 95 Ltd Bulgaria" and model K1CPW8.

Dokumenti Relatati - K1CPW8

Preview Bojlers Prity: Deskrizzjoni Teknika, Installazzjoni, u Manwal tat-Tħaddim
Gwida komprensiva għall-bojlers residenzjali Prity, li tkopri l-ispeċifikazzjonijiet tekniċi, il-proċeduri ta' installazzjoni, l-istruzzjonijiet tat-tħaddim, il-manutenzjoni, u s-soluzzjoni tal-problemi għal mudelli ta' fjuwil solidu u pellet.