Apogee MQ-210

Manwal tal-Utent tal-Apogee MQ-210 Quantum Light PAR Meter taħt l-Ilma

Model: MQ-210

1. Introduzzjoni

The Apogee MQ-210 Quantum Light PAR Meter is designed for precise measurement of Photosynthetic Active Radiation (PAR) in underwater environments. This device features a waterproof quantum sensor connected to a handheld meter. The MQ-210 is specifically engineered to apply an immersion effect correction factor directly through its firmware, ensuring accurate readings in aquatic settings. It is suitable for various light sources, though specific post-measurement correction factors may be required for LED light sources to achieve optimal accuracy.

Important Note: While the sensor and its cable are fully waterproof, the handheld meter unit is NOT waterproof and must be kept dry.

2. Informazzjoni dwar is-Sigurtà

  • Always ensure the handheld meter remains dry. Exposure to water will damage the unit and void the warranty.
  • Do not attempt to open or modify the handheld meter or the sensor. This can lead to damage and inaccurate readings.
  • Handle the sensor cable with care to prevent kinks or damage, which could compromise its waterproof integrity.
  • Keep the device away from extreme temperatures and direct sunlight when not in use.
  • Use only specified batteries (if applicable, refer to product packaging or Apogee documentation).

3. Kontenut tal-Pakkett

Upon unpacking, please verify that all the following components are present:

  • Apogee MQ-210 Handheld Meter
  • Waterproof Quantum Sensor (attached via cable)
  • Manwal għall-Utent (dan id-dokument)

4. Prodott Aktarview

The MQ-210 system comprises two main parts: the handheld display unit and the waterproof quantum sensor.

Apogee MQ-210 Underwater Quantum Light PAR Meter with handheld unit and sensor

Figura 1: Apogee MQ-210 Underwater Quantum Light PAR Meter. This image displays the complete MQ-210 unit, featuring the handheld meter with its digital display and control buttons, connected by a cable to the compact, black waterproof quantum sensor. The sensor is designed for submersion, while the handheld unit is for dry use.

4.1 Handheld Meter

The handheld meter features a digital display for showing PAR readings in µmol m⁻² s⁻¹. It includes control buttons for power, sampling, and mode selection. The meter processes the raw sensor data and applies the immersion effect correction factor.

4.2 Waterproof Quantum Sensor

Close-up of Apogee waterproof quantum sensor

Figura 2: Close-up view of the Apogee waterproof quantum sensor. This image highlights the robust, anodized aluminum body and the acrylic diffuser of the sensor head. The sensor contains a blue-enhanced silicon photodiode and custom optical filters, designed for accurate underwater PAR measurements.

The sensor incorporates a blue-enhanced silicon photodiode and custom optical filters housed within a rugged, anodized aluminum body with an acrylic diffuser. It is designed for full submersion in water, making it ideal for applications such as saltwater aquariums.

5. Setup

  1. Spakkja l-Apparat: Carefully remove the handheld meter and sensor from its packaging.
  2. Spezzjona għal Ħsara: Check the handheld meter, sensor, and cable for any visible signs of damage. If damage is found, do not proceed with setup and contact support.
  3. Installazzjoni tal-Batterija (jekk applikabbli): If the meter requires user-installed batteries (not specified, but common for handheld devices), open the battery compartment (usually on the back) and insert the correct type and number of batteries, observing polarity.
  4. Konnessjoni tas-Sensor: The quantum sensor is permanently attached to the handheld meter via a waterproof cable. Ensure the cable connection point to the sensor is secure and undamaged.
  5. Qawwa Inizjali Mixgħula: Press the power button on the handheld meter to turn it on. The display should illuminate and show a reading.

6. Istruzzjonijiet Operattivi

6.1 Tixgħel/Jitfi

  • Biex tixgħel il-miter, agħfas il-buttuna Qawwa button (usually marked with a circle and vertical line symbol).
  • Biex tintefa, agħfas u żomm il-buttuna Qawwa buttuna sakemm il-wiri jintefa.

6.2 Teħid tal-Kejl

  1. Pożizzjona s-Sensor: Carefully submerge the waterproof quantum sensor into the water at the desired depth and location for measurement. Ensure the sensor's acrylic diffuser is clean and unobstructed.
  2. Observe Readings: The handheld meter's display will show the real-time PAR reading in µmol m⁻² s⁻¹. The MQ-210 automatically applies the immersion effect correction factor in its firmware for underwater measurements.
  3. Sampling (if applicable): If the meter has a "sample" button, pressing it may log the current reading or provide a stable reading. Refer to the on-screen indicators for specific sampfunzjonijiet ling.
  4. Mode Selection (if applicable): Use the "mode" button to cycle through different display modes or settings if available.

6.3 LED Light Source Considerations

While the MQ-210 is excellent for most light sources, when measuring PAR from LED light sources, post-measurement correction factors may need to be applied for the most accurate results. Consult Apogee Instruments' official documentation or website for specific correction factors pertaining to various LED types.

7. Manutenzjoni

7.1 Tindif

  • Sensor: After each use in water, rinse the sensor with fresh water to remove any salt, debris, or biological film. Gently wipe the acrylic diffuser with a soft, non-abrasive cloth. Avoid using harsh chemicals or abrasive materials that could scratch the diffuser.
  • Handheld Meter: Clean the handheld meter with a dry, soft cloth. Do not use liquid cleaners or immerse the meter in water.

7.2 Ħażna

  • Store the MQ-210 in a cool, dry place away from direct sunlight and extreme temperatures.
  • If storing for extended periods, remove batteries from the handheld meter to prevent leakage (if applicable).
  • Keep the sensor and cable free from kinks or sharp bends during storage.

8 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Il-miter ma jixgħelx.Batteriji mejta jew installati ħażin.Ibdel il-batteriji b'oħrajn ġodda, filwaqt li tiżgura polarità korretta.
Inaccurate or erratic readings.
  • Dirty sensor diffuser.
  • Damaged sensor or cable.
  • Incorrect application of LED correction factor (for LED sources).
  • Clean the sensor diffuser gently.
  • Inspect sensor and cable for damage. If damaged, contact support.
  • Refer to Apogee documentation for LED correction factors.
Display shows "Error" or unusual characters.Ħsara interna jew problema bis-sensor.Try powering off and on again. If the error persists, contact Apogee Instruments support.
Il-buttuni ma jirrispondux.Internal button malfunction or software issue.Power cycle the device. If buttons remain unresponsive, contact Apogee Instruments support.

9. Speċifikazzjonijiet

KaratteristikaDettall
MudellMQ-210
Tip ta' KejlUnderwater Photosynthetic Active Radiation (PAR)
Tip tas-SensorBlue-enhanced silicon photodiode with custom optical filters
Materjal tal-Korp tas-SensorRugged, anodized aluminum with acrylic diffuser
Immersion Effect CorrectionAutomatically applied via firmware
Handheld Meter Water ResistanceMhux reżistenti għall-ilma
Sensor Water ResistanceKompletament reżistenti għall-ilma
ManifatturApogee Instruments

10. Garanzija u Appoġġ

For detailed warranty information, technical support, or service inquiries, please contact Apogee Instruments directly. Refer to their official webis-sit għad-dettalji ta' kuntatt u l-politiki ta' garanzija l-aktar aġġornati.

It is recommended to register your product with Apogee Instruments to ensure you receive updates and support.

Dokumenti Relatati - MQ-210

Preview Gwida għall-Utent tal-Apogee Duet 2: Konfigurazzjoni, Tħaddim, u Applikazzjonijiet
Din il-gwida għall-utent tipprovdi struzzjonijiet komprensivi għall-interfaċċja awdjo Apogee Duet 2, li tkopri s-setup, il-konnessjoni, it-tħaddim, l-integrazzjoni ma' DAWs bħal Logic Pro u GarageBand, u s-soluzzjoni tal-problemi għall-utenti tal-Mac.
Preview Issolvi l-Problemi tal-Apogee Symphony I/O: Problemi ta' Ebda Qawwa Mixgħula
Bullettin tekniku minn Apogee Electronics li jipprovdi passi għas-soluzzjoni tal-problemi biex jiġu solvuti kwistjonijiet ta' 'bla qawwa mixgħula' bl-interfaċċja awdjo Symphony I/O. Ikopri sintomi komuni u jiggwida lill-utenti dwar kif jiċċekkjaw il-firmware, il-kejbils, il-provvista tal-enerġija, u l-bordijiet taċ-ċirkwiti.
Preview Gwida għall-Utent tal-Apogee Duet 3
Gwida komprensiva għall-utent għall-interfaċċja awdjo Apogee Duet 3, li tkopri s-setup, l-installazzjoni tas-softwer, il-konnettività, il-konfigurazzjoni mad-DAWs, karatteristiċi avvanzati, u s-soluzzjoni tal-problemi.
Preview Gwida għall-Utent taż-Żfin ta' Apogee Clearmountain: Karatteristiċi u Setup tal-Plugin tad-Delay
Gwida komprensiva għall-utent għall-plugin Dance delay ta' Apogee's Clearmountain. Tgħallem dwar l-emulazzjoni tat-tejp analogu tiegħu, id-dewmien tal-ping pong, l-installazzjoni, ir-rottaġġ tas-sinjali, u s-soluzzjoni tal-problemi.
Preview Gwida għall-Utent ta' Apogee Symphony Studio: Interfaċċja tal-Awdjo b'Riżoluzzjoni Għolja
Gwida komprensiva għall-utent għall-interfaċċja awdjo tas-Serje Apogee Symphony Studio, li tkopri s-setup, it-tħaddim, il-kontroll tas-softwer, il-flussi tax-xogħol tal-monitor, u l-ispeċifikazzjonijiet tekniċi għall-produzzjoni awdjo professjonali.
Preview Sistema ta' Subwoofer Apogee AFI-118: Subwoofer Awdjo Professjonali ta' 18-il pulzier b'Prestazzjoni Għolja
Speċifikazzjonijiet u karatteristiċi dettaljati tas-Sistema tas-Subwoofer Apogee AFI-118, subwoofer ta' qawwa għolja ta' 18-il pulzier (460mm) iddisinjat għal applikazzjonijiet awdjo professjonali, inkluż ħoss live, klabbs, u teatri. Tgħallem dwar id-drajver, id-dejta tal-inġinerija, u l-kompatibilità tiegħu.