Introduzzjoni
This manual provides comprehensive instructions for the Anderic Replacement FAN-9T Thermostatic Remote Control, designed specifically for Hampton Bay ceiling fans.

Immaġni: Quddiem view of the Anderic FAN-9T remote control, showing the display and various control buttons.
Kompatibilità
The Anderic FAN-9T remote control is compatible with Hampton Bay ceiling fans. To ensure compatibility, verify that your original remote control has "FAN-9T" printed on its back. This remote features FCC ID: L3HFAN9T and PN: FAN9TR.
Nota Importanti: This remote control provides on/off functionality for lights and does not support dimming. If your original remote for a Windward II 54-inch Ceiling Fan has a model number starting with "CHQ" (located on the back), you may require the RR7096TR model with a yellow light button, even if your original has a green light button.
Karatteristiċi Ewlenin
- Operazzjoni b'lura: Easily switch the ceiling fan's rotation direction for optimal airflow in different seasons.
- Thermostatic Function: Set a desired temperature, and the remote will automatically adjust fan speed to maintain a comfortable environment.
- Lights On/Off Control: Conveniently turn your ceiling fan's lights on or off with a dedicated button.
- Konverżjoni tat-temperatura: Switch between Celsius and Fahrenheit temperature displays by holding the TEMP UP and TEMP DOWN buttons simultaneously for 3 seconds.
- Wall Mount Holder: Includes a wall mount holder for convenient storage and accessibility of the remote.
Setup Istruzzjonijiet
Before using your new Anderic FAN-9T remote control, follow these steps to install batteries and set the correct code for your ceiling fan receiver.
1. Installazzjoni tal-batterija
- Remove the battery cover located on the back of the remote control. Press firmly below the arrow and slide the cover off.
- Daħħal erba’ (4) batteriji AAA, waqt li tiżgura l-polarità korretta (+/-).
- Ibdel l-għatu tal-batterija.

Immaġni: Wara view of the remote control with the battery cover removed, revealing the battery slots and DIP switches.
2. Setting the Code (DIP Switches)
The remote control and your ceiling fan receiver must be set to the same code for proper communication. This unit has 16 different code combinations. Ensure your fan is operated in "HIGH SPEED" and the light is in "ON" condition at the switch knob before proceeding.
- L-issettjar tal-kodiċi fuq ir-remote:
- With the battery cover removed, locate the DIP switches inside the battery compartment.
- Slide the code switches to your desired up or down position. (Factory setting is all up. Do not use this position unless it matches your receiver.) Use a small screwdriver or a ballpoint pen to firmly slide the switches.
- Replace the battery cover on the transmitter (remote).
- L-issettjar tal-kodiċi fuq ir-riċevitur:
- Locate the receiver unit within your ceiling fan assembly.
- Slide the code switches on the receiver to the exact same positions (up/down) as you set on your remote control.

Image: Diagram illustrating how to set the code switches on both the remote control (transmitter) and the ceiling fan receiver.
Once both the remote and receiver codes are matched, your remote control should be ready for operation.
Istruzzjonijiet Operattivi
Familiarize yourself with the buttons on your Anderic FAN-9T remote control to operate your ceiling fan effectively.

Immaġni: Angolata view of the Anderic FAN-9T remote control, highlighting the button layout.
- Kontroll tal-veloċità tal-fann: Use the "MANUAL LOW" and "HIGH" indicators on the display to adjust fan speed. The remote automatically adjusts fan speed in thermostatic mode.
- Buttuna tal-FAN AUTO: Activates or deactivates the automatic fan speed adjustment based on the set temperature.
- FOR/REV Button: Press this button to change the direction of the fan blades (forward for cooling, reverse for heat circulation).
- Buttuna tad-Dawl: Press to turn the ceiling fan lights ON or OFF. (Note: This remote does not support dimming.)
- Buttuna TIMER: Activates the fan timer function. Refer to your fan's specific instructions for timer settings.
- Buttuna tad-Dewmien tad-Dawl: Activates the light delay function. Refer to your fan's specific instructions for light delay settings.
- TEMP UP / TEMP DOWN Buttons: Adjust the desired temperature setting for the thermostatic function.
- Temperature Unit Conversion (C/F): To switch between Celsius and Fahrenheit, hold down the TEMP UP and TEMP DOWN buttons simultaneously for 3 seconds.
Manutenzjoni
- Tindif: Imsaħ il-kontroll remot b'ċarruta ratba u niexfa. Tużax prodotti tat-tindif jew solventi li joborxu.
- Sostituzzjoni tal-batterija: Replace batteries when the remote's performance degrades or the display becomes dim. Always use new AAA batteries and dispose of old batteries responsibly.
- Ħażna: Meta ma tkunx qed tużah għal perjodi twal, neħħi l-batteriji biex tevita t-tnixxija. Aħżen ir-remote f'post frisk u niexef.

Image: The Anderic FAN-9T remote control securely placed in its included wall mount holder.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Remote not responding / Fan not working. |
|
|
| Id-dwal ma jaħdmux. |
|
|
| Il-wiri tat-temperatura mhux korrett. | Incorrect temperature unit setting. | Hold TEMP UP and TEMP DOWN buttons simultaneously for 3 seconds to switch between Celsius and Fahrenheit. |
Speċifikazzjonijiet
| Attribut | Dettall |
|---|---|
| Dimensjonijiet tal-Prodott | 3 x 1 x 6 pulzieri |
| Piż tal-oġġett | 4.8 uqija |
| Numru tal-Mudell | FAN9T |
| Batteriji Meħtieġa | 4 batteriji AAA |
| Kulur | Abjad |
| Apparati Kompatibbli | HampFannijiet tas-Saqaf ta' ton Bay |
| ID tal-FCC | L3HFAN9T |
| PN | FAN9TR |