1. Prodott Aktarview
The Genasun GV-5-Pb-12V is a high-speed Maximum Power Point Tracking (MPPT) solar charge controller designed for 12V lead-acid batteries. It features a 5A charging current and a 5A DC load output with Low Voltage Disconnect (LVD). This controller is built for efficiency and durability, offering advanced electronic protections and a multi-stage charge profile to optimize battery health and lifespan.
- Max. recommended panel power: 65 W
- Kurrent tal-iċċarġjar: 5 A
- Multi-stage charge profile for Lead-Acid batteries
- High-Speed MPPT: 15 Hz (15 times per sec.) tracking speed
- L-ogħla Effiċjenza: 99.85%
- Tiny night consumption: 0.125 mA
- DC Load Output: 5 A with LVD (low voltage skonnettja)
- Advanced electronic protections for reverse panel and battery polarity
- 10-Sena Garanzija
- Made in the USA, conform to CE, FCC, RoHS

2. Informazzjoni dwar is-Sigurtà
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in damage to the unit, battery, or solar panel, and may void the warranty. Ensure all connections are secure and correct polarity is observed.
- Always connect the battery to the charge controller FIRST.
- Always disconnect the solar panel from the charge controller FIRST before disconnecting the battery.
- Ensure proper ventilation around the charge controller.
- Do not expose the controller to water or excessive moisture unless it is a waterproof model.
- Uża gauges tal-wajer xierqa għall-konnessjonijiet kollha biex tevita li jisħnu żżejjed.
3. Setup u Installazzjoni
Follow these steps for proper installation of your Genasun GV-5-Pb-12V solar charge controller.
3.1 Dijagramma tal-Wiring

This diagram illustrates the correct connection sequence for your solar panel, battery, and optional DC load. Ensure positive (+) and negative (-) terminals are correctly matched.
3.2 Passi ta' Konnessjoni
- Qabbad il-batterija: First, connect the battery to the charge controller. Ensure correct polarity (positive to positive, negative to negative). The controller will power on and display the battery voltage.
- Agħżel it-Tip tal-Batterija: If your controller has a battery type selection feature, press and hold the leftmost button until the battery type indicator flashes. Select the appropriate battery type (e.g., Lead-Acid, AGM, Gel). For Lead-Acid batteries, selecting AGM is often suitable.
- Qabbad il-Panel Solari: Next, connect the solar panel to the charge controller. Ensure correct polarity. The controller will begin charging the battery if sufficient solar power is available.
- Qabbad it-Tagħbija DC (Mhux obbligatorja): If using the optional DC load output, connect your DC load (e.g., lights, fan) to the LOAD terminals. The controller's Low Voltage Disconnect (LVD) feature will protect the battery from over-discharge.
3.3 Gwida għall-Installazzjoni Viżwali
4. Istruzzjonijiet Operattivi
Once correctly installed, the Genasun GV-5-Pb-12V operates automatically. The multicolor LED provides status indications:
- LED aħdar: Indicates normal operation and charging status.
- LED aħmar: Indicates an error or fault condition. Refer to the troubleshooting section for details.
- Batterija Voltage Display: The integrated display shows the current battery voltage, allowing you to monitor the charge level.
The MPPT technology continuously tracks the maximum power point of your solar array to ensure optimal charging efficiency, even in varying light conditions.
5. Manutenzjoni
To ensure optimal performance and longevity of your Genasun GV-5-Pb-12V solar charge controller, follow these maintenance guidelines:
- Spezzjoni regolari: Iċċekkja l-konnessjonijiet kollha tal-wajers perjodikament biex tiżgura li huma ssikkati u ħielsa mill-korrużjoni.
- Tindif: Keep the controller clean and free from dust, dirt, and debris. Use a dry cloth for cleaning. Do not use harsh chemicals or abrasive materials.
- Ventilazzjoni: Ensure the area around the controller is well-ventilated to prevent overheating.
- Saħħa tal-batterija: Regularly check your battery's condition as per the battery manufacturer's recommendations.
6 Issolvi l-problemi
If you encounter issues with your Genasun GV-5-Pb-12V, refer to the following common troubleshooting tips:
- Ebda Iċċarġjar:
- Check all solar panel connections for correct polarity and secure fit.
- Kun żgur li l-pannell solari qed jirċievi dawl tax-xemx adegwat.
- Verify the battery is properly connected and has sufficient voltage (above the minimum operating voltagu).
- Indikatur LED aħmar:
- A red LED typically indicates a fault. Check for reverse polarity on either the solar panel or battery connections.
- Żgura li l-batterija voltage is within the acceptable range for the controller.
- Check for short circuits on the load output.
- It-Tagħbija Mhux Taħdem:
- Check connections to the DC load output.
- Ivverifika l-volum tal-batterijatage hija 'l fuq mill-Volum Baxxtage Disconnect (LVD) threshold. The controller will automatically reconnect the load once the battery voltagjirkupra.
- Ensure the load current does not exceed 5A.
If problems persist, contact Genasun customer support for assistance.
7. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Numru tal-Mudell | GV-5-Pb-12V |
| Qawwa Massima Rakkomandata tal-Panel | 65 W |
| Kurrent tal-Iċċarġjar | 5 A |
| Tip ta 'batterija | 12 V Lead-Acid Batteries |
| MPPT Tracking Speed | 15 Hz (15 times per sec.) |
| L-ogħla Effiċjenza | 99.85% |
| Night Consumption | 0.125 mA |
| Output ta 'Tagħbija DC | 5 A with LVD |
| Temperatura operattiva | -40°C sa 85°C |
| Dimensjonijiet tal-Prodott | 4.3 x 2.2 x 0.9 pulzieri |
| Piż tal-oġġett | 2.88 uqija |
| Ċertifikazzjonijiet | CE, FCC, RoHS |

8. Garanzija
The Genasun GV-5-Pb-12V MPPT Solar Charge Controller comes with a 10-Sena Garanzija. This warranty covers defects in materials and workmanship under normal use and service conditions. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, please refer to the official Genasun websit jew ikkuntattja l-appoġġ tal-klijent.
9. Appoġġ
For further assistance, technical support, or warranty inquiries, please visit the official Genasun website or contact their customer service department. You can find more information and resources at www.genasun.com.