1. Introduzzjoni
This instruction manual provides essential information for the proper use, setup, and maintenance of your Perfect-Prime TL0700 K-Type Sensor Probe. Please read this manual thoroughly before using the product to ensure accurate measurements and safe operation. Retain this manual for future reference.

Stampa 1.1: Ġenerali fuqview of thermocouple probes and sensors.
2. Prodott Aktarview u Karatteristiċi
The Perfect-Prime TL0700 is a K-Type thermocouple sensor probe designed for precise temperature measurements across a wide range. It is compatible with various K-Type thermocouple thermometers and meters.
Karatteristiċi ewlenin:
- Firxa tat-Temperatura Operattiva: -30 °C sa 700 °C (-22 °F sa 1292 °F)
- Tul tas-Sonda: 100 cm (1 Meter)
- Sensor and Wire Material: USA Thermocouple Sensor and Wire with Glass Braid Insulation
- Dijametru tal-Wajer: 0.5 mm x 2
- Package Diameter: Madwar 3 mm
- Tip ta' Konnettur: Flat Shape Male K-Type Connector

Image 2.1: The Perfect-Prime TL0700 K-Type Sensor Probe, showing the coiled wire and the yellow flat male connector.
3. Setup
Follow these steps to properly set up your TL0700 K-Type Sensor Probe:
- Spezzjona s-Sonda: Before each use, visually inspect the probe wire and connector for any signs of damage, fraying, or corrosion. Do not use if damage is observed.
- Identify Connector: The TL0700 probe features a standard flat shape male K-Type connector, typically colored yellow.
- Connect to Thermometer: Insert the male connector of the TL0700 probe into the corresponding female K-Type input port on your compatible thermometer or meter. Ensure a firm and secure connection. The polarity of K-Type connectors is standardized, but always ensure the pins align correctly.
- Qawwa Mixgħul: Turn on your K-Type thermometer/meter according to its specific instructions.

Immaġni 3.1: Dettaljata view of the K-Type flat male connector, highlighting its design for secure connection.

Immaġni 3.2: Eż.ample of a K-Type thermometer with multiple probes connected, illustrating typical usage.
4. Istruzzjonijiet Operattivi
Once the TL0700 probe is securely connected to your K-Type thermometer, you can begin taking temperature measurements:
- Pjazzament: Carefully position the tip of the sensor probe at the point where you wish to measure the temperature. Ensure good thermal contact with the object or medium.
- Stabbilizzazzjoni: Allow a few moments for the temperature reading on your thermometer to stabilize. The response time for this probe is approximately 500 milliseconds, but stabilization time may vary depending on the thermal mass of the object being measured and the thermometer's processing speed.
- Aqra l-Kejl: Read the temperature displayed on your thermometer.
- Firxa tat-Temperatura: Ensure that the measured temperature falls within the probe's specified operating range of -30 °C to 700 °C (-22 °F to 1292 °F). Exceeding this range can damage the probe.
Nota: The accuracy of the measurement depends on both the probe and the connected thermometer. Refer to your thermometer's manual for its specific accuracy specifications and calibration procedures.
5. Manutenzjoni
Proper maintenance ensures the longevity and accuracy of your TL0700 K-Type Sensor Probe:
- Tindif: After each use, especially when measuring in corrosive or dirty environments, gently wipe the probe tip and wire with a clean, damp cloth. For stubborn residues, use a mild, non-abrasive cleaner. Ensure the probe is completely dry before storage.
- Ħażna: Store the probe in a clean, dry environment, away from extreme temperatures, direct sunlight, and corrosive chemicals. Avoid kinking or sharply bending the wire, as this can damage the internal conductors and insulation.
- Spezzjoni: Regularly inspect the probe for any physical damage, such as cuts in the insulation, exposed wires, or bent connector pins. Replace the probe if any damage is detected to prevent inaccurate readings or electrical hazards.
6 Issolvi l-problemi
If you encounter issues with your TL0700 K-Type Sensor Probe, consider the following:
- Ebda Qari jew Qari Erratiku:
- Ensure the probe is securely connected to the thermometer.
- Check if the thermometer is set to the correct K-Type input mode.
- Inspect the probe wire and connector for damage. A damaged probe may need replacement.
- Verify that the thermometer itself is functioning correctly by testing with another known good K-Type probe if available.
- Qari mhux eżatt:
- Ensure good thermal contact between the probe tip and the object being measured.
- Ħalli biżżejjed ħin biex il-qari jistabbilizza ruħu.
- Confirm that the measured temperature is within the probe's specified operating range.
- Consider if the probe needs calibration, or if the thermometer requires calibration.
7. Speċifikazzjonijiet
| Speċifikazzjoni | Valur |
|---|---|
| Firxa tat-Temperatura Operattiva | -30 °C sa 700 °C (-22 °F sa 1292 °F) |
| Tul tas-Sonda | 100 cm (1 Meter) |
| Dijametru tal-Wajer | 0.5 mm x 2 |
| Package Diameter | ~ 3 mm |
| Tip ta' Konnettur | Flat Shape Male K-Type |
| Ħin ta' Rispons | 500 millisekondi |
| Manifattur | Prim Perfett |
| Numru tal-Mudell tal-Artiklu | COMINHKPR131550 |
| UPC | 638414477455 |
| Dimensjonijiet tal-Pakkett | 12.9 x 12.7 x 0.99 ċm; 31.75 gramma |

Image 7.1: PerfectPrime probes are compatible with various branded and non-branded products.
8. Garanzija u Appoġġ
For specific warranty information regarding your Perfect-Prime TL0700 K-Type Sensor Probe, please refer to the documentation included with your purchase or visit the official PerfectPrime websit. It-termini tal-garanzija jistgħu jvarjaw skont ir-reġjun u l-bejjiegħ bl-imnut.
If you require technical assistance, have questions about product functionality, or need to report an issue, please contact PerfectPrime customer support through their official channels. Contact information can typically be found on the manufacturer's webis-sit jew fuq l-imballaġġ tal-prodott tiegħek.