HILTI 3436798

Hilti CP 606 Firestop Sealant Instruction Manual

Model: CP 606 (3436798)

1. Prodott Aktarview

The Hilti CP 606 Firestop Sealant is a high-performance, intumescent acrylic sealant designed for firestopping applications. It expands when exposed to heat, forming a fire-resistant barrier that helps prevent the spread of fire and smoke through penetrations in fire-rated constructions. This product is suitable for various joint and penetration sealing applications in walls and floors.

Hilti CP 606 Firestop Sealant 10.5oz tube

An image showing a single 10.5oz tube of Hilti CP 606 red firestop sealant, clearly displaying the Hilti logo and product identification.

2. Informazzjoni dwar is-Sigurtà

Always prioritize safety when working with sealants. Read and understand the Safety Data Sheet (SDS) before use. Observe all local safety regulations.

  • Tagħmir Protettiv Personali (PPE): Wear appropriate PPE, including safety glasses, gloves, and protective clothing, to prevent skin and eye contact.
  • Ventilazzjoni: Use in well-ventilated areas. If adequate ventilation is not available, use respiratory protection.
  • Kuntatt mal-ġilda: F'każ ta' kuntatt mal-ġilda, aħsel sew bis-sapun u l-ilma.
  • Kuntatt mal-għajnejn: In case of eye contact, flush immediately with plenty of water for several minutes and seek medical attention.
  • Inġestjoni: Tiblax. Jekk jinbela', fittex attenzjoni medika immedjata.
  • Żomm 'il bogħod: Żomm fejn ma jintlaħaqx mit-tfal u l-annimali domestiċi.

3. Setup u Preparazzjoni

  1. Preparazzjoni tal-wiċċ: Ensure all surfaces to be sealed are clean, dry, and free from dust, oil, grease, loose particles, and other contaminants. Substrates should be sound and stable.
  2. Joint Dimensions: Verify that joint dimensions are within the product's specified limits for optimal performance.
  3. Materjal ta' Sostenn: For deeper joints, use a suitable backing material (e.g., backer rod) to control sealant depth and ensure proper sealant geometry.
  4. Għodod Meħtieġa:
    • Standard caulking gun
    • Utility knife or sealant cutter
    • Trowel or tooling stick for finishing
    • Cleaning supplies (rags, appropriate solvent if needed)
  5. Temperatura: Apply the sealant within the recommended temperature range, typically between 5°C and 40°C (41°F and 104°F).

4. Istruzzjonijiet għall-Applikazzjoni

  1. Prepare Cartridge: Cut the tip of the sealant tube at a 45-degree angle to the desired bead size. Puncture the inner seal of the cartridge.
  2. Load Caulking Gun: Insert the prepared cartridge into a standard caulking gun.
  3. Applika siġillant: Apply the sealant evenly and continuously into the joint or penetration, ensuring full contact with the substrate. Maintain consistent pressure on the trigger to achieve a smooth, uniform bead.
  4. Għodda: Within 5-10 minutes of application (before skinning occurs), tool the sealant to ensure good adhesion and a smooth finish. Remove any excess sealant immediately.
  5. Vulkanizzar: The sealant will skin over in approximately 15-30 minutes, depending on temperature and humidity. Full cure time can range from several days to weeks, depending on bead thickness and environmental conditions. Protect the freshly applied sealant from water and heavy traffic until fully cured.

5. Manutenzjoni

Once cured, Hilti CP 606 Firestop Sealant requires minimal maintenance. Periodically inspect sealed joints and penetrations for any signs of damage, cracking, or degradation. If damage is observed, clean the area and reapply sealant as necessary to maintain the firestop integrity.

6 Issolvi l-problemi

  • Adeżjoni fqira:

    Ensure surfaces are clean, dry, and free of contaminants. Proper surface preparation is critical for good adhesion.

  • Slow Curing:

    Low temperatures and high humidity can extend curing times. Ensure adequate ventilation and maintain recommended application temperatures.

  • Cracking or Shrinkage:

    Excessive joint movement or improper joint design can lead to cracking. Ensure correct joint dimensions and use of backing material where appropriate.

7. Speċifikazzjonijiet

KaratteristikaDettall
BrandHILTI
Numru tal-Mudell3436798 (CP 606)
Formola tal-OġġettLiquid (Sealant)
KulurAħmar
Daqs tal-Kontenitur10.5 oz Tube
Livell ta 'Reżistenza għall-IlmaWaterproof
ManifatturHilti
L-Ewwel Data Disponibbli9 ta’ Ottubru, 2017

8. Ħażna u Rimi

  • Ħażna: Store the sealant in its original, unopened packaging in a cool, dry place, away from direct sunlight and extreme temperatures. Recommended storage temperature is typically between 5°C and 25°C (41°F and 77°F).
  • Rimi: Dispose of unused product and empty containers in accordance with local, state, and federal regulations. Do not dispose of in drains or waterways. Consult local waste management authorities for proper disposal methods.

9. Garanzija u Appoġġ

For specific warranty information regarding the Hilti CP 606 Firestop Sealant, please refer to the official Hilti website or contact Hilti customer service directly. Hilti provides comprehensive technical support and product documentation to assist with proper application and performance.

Uffiċjali ta' Hilti Websit: www.hilti.com

Dokumenti Relatati - 3436798

Preview Siġillant Akriliku Hilti Firestop CFS-S ACR / CP 606 - Gwida għall-Applikazzjoni
Gwida komprensiva għall-applikazzjoni tas-Siġillant Akriliku Hilti Firestop CFS-S ACR / CP 606, li tiddeskrivi l-proċeduri tas-siġillar tal-ġonot u l-penetrazzjoni b'informazzjoni dwar it-tqaddid u linji gwida dwar is-sigurtà.
Preview Sistema ta' Kisi kontra n-Nar Hilti CP 670: Fowlder ta' Sottomissjoni u Dejta Teknika
Fowlder komprensiv ta' sottomissjoni għas-Sistema ta' Kisi tan-Nar Hilti CP 670, inkluż informazzjoni dwar il-prodott, dikjarazzjonijiet tal-metodu, rapporti tat-testijiet mill-Università ta' Macau, kontenut ta' VOC, approvazzjonijiet, pajjiż ta' oriġini, informazzjoni LEED, u konferma mingħajr CFC/ożonu. Jiddettalja l-ispeċifikazzjonijiet tekniċi, il-proċeduri tal-applikazzjoni, u r-referenzi tax-xogħol.
Preview Hilti Technical Manuals: Fire Protection Solutions for Systems, Joints, and Facades
Comprehensive technical manuals from Hilti detailing fire protection solutions for systems, joints, and facades, including sealants, bandages, collars, blocks, and cavity barriers.
Preview Gwida għall-Utent tas-Selettur tan-Nar Hilti fuq HCP 2.0
Gwida komprensiva għall-utent għan-navigazzjoni u l-użu tal-għodda Hilti Firestop Selector fuq il-Hilti Construction Platform (HCP) 2.0, li tkopri l-login, is-settings, it-tiftix, il-ġenerazzjoni tas-sottomissjonijiet, u l-karatteristiċi tal-app mobbli.
Preview Hilti CP 617 Firestop Putty Pad Installation Guide
Detailed installation instructions for the Hilti CP 617 Firestop Putty Pad, covering preparation, application steps, and proper sizing for electrical boxes to ensure fire safety compliance.
Preview Manwal Tekniku u Applikazzjonijiet tal-Faxxa Kontra n-Nar Hilti CFS-B
Manwal tekniku komprensiv għall-Faxxa Hilti Firestop CFS-B, li jiddeskrivi l-applikazzjonijiet tagħha, vantaġġitages, speċifikazzjonijiet tekniċi, struzzjonijiet għall-installazzjoni, gwida għall-konsum, u użi approvati għall-qtugħ tan-nar ta' diversi tipi ta' pajpijiet f'kostruzzjonijiet differenti ta' ħitan u pavimenti.