1. Introduzzjoni
This manual provides essential information for the safe and efficient operation of the uxcell DC 12V 300mA 1300ml Water Flow Self Priming Diaphragm Micro Water Pump. Please read these instructions thoroughly before installation and use to ensure proper function and longevity of the product.
This micro water pump is designed for various applications requiring liquid circulation and transfer, such as in coffee machines, water dispensers, and experimental models.
2. Informazzjoni dwar is-Sigurtà
- Sigurtà Elettrika: Ensure the power supply matches the pump's specifications (DC 12V). Incorrect voltage can damage the pump or pose a safety hazard.
- Sigurtà tal-Ilma: This pump is designed for water and similar non-corrosive liquids. Do not use with flammable, corrosive, or highly viscous fluids.
- Installazzjoni: Installation should be performed by individuals with appropriate technical knowledge. Ensure all connections are secure to prevent leaks and electrical shorts.
- Operazzjoni: Tħaddimx il-pompa xotta għal perjodi twal, għax dan jista' jikkawża ħsara.
- Manutenzjoni: Skonnettja l-enerġija qabel ma tagħmel xi manutenzjoni jew tindif.
3. Prodott Aktarview
The uxcell Micro Water Pump is a compact, self-priming diaphragm pump suitable for various liquid transfer tasks. Its design emphasizes low noise and stable performance.
3.1 Karatteristiċi ewlenin
- Self-priming function for convenient operation.
- Low noise output during operation.
- Easy installation and stable performance.
- Disinn kompatt u ħafif.
3.2 Komponenti
The pump consists of a DC motor, a diaphragm pumping mechanism, and inlet/outlet ports. The main body is constructed from plastic and metal components.

Figura 1: Quddiem view of the uxcell DC 12V Micro Water Pump, showing the main body and water inlet/outlet ports.

Figura 2: Ġenb view of the pump, displaying the motor housing and product label with model information.
4. Setup
- Immuntar: Secure the pump in a stable position. While the pump is compact, proper mounting helps reduce vibration and noise.
- Konnessjoni tat-tubi: Connect appropriate tubing to the water inlet and outlet ports. The water hole inner diameter is 4mm (0.16"). Ensure connections are tight to prevent leaks.
- Konnessjoni Elettrika: Connect the pump to a DC 12V power source. Observe correct polarity (positive to positive, negative to negative) to ensure proper operation. The pump's terminals are small; soldering or secure crimp connections are recommended for reliable contact.
- Priming: As a self-priming pump, it can draw liquid from a lower level. However, for initial setup, ensuring the inlet tubing is submerged in liquid can aid in faster priming.

Figura 3: Diagram illustrating the dimensions of the uxcell DC 12V Micro Water Pump, including overall length (81mm) and diameter (27mm), and port length (42mm) and diameter (4.5mm).
5. Istruzzjonijiet Operattivi
- Qawwa Mixgħul: Once all connections are secure and the inlet is submerged in liquid, apply DC 12V power to the pump.
- Monitoraġġ tal-Fluss: Observe the liquid flow. The pump has a maximum flow rate of 1300 ± 50 ml/min.
- Operazzjoni Kontinwa: The pump is designed for continuous operation within its specified parameters. Avoid running the pump dry.
- Itfi: Disconnect the power supply to stop the pump.
6. Manutenzjoni
- Spezzjoni regolari: Periodically check tubing for kinks, blockages, or wear. Inspect electrical connections for corrosion or looseness.
- Tindif: If the pump's performance degrades due to sediment or mineral buildup, flush it with clean water or a mild descaling solution (if compatible with the pump's materials). Ensure the pump is thoroughly rinsed afterward.
- Ħażna: If storing the pump for an extended period, ensure it is clean and dry.
7 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-pompa ma tibdax. | Ebda qawwa, volum mhux korretttage, loose electrical connections, incorrect polarity. | Verify power supply (DC 12V), check all electrical connections, ensure correct polarity. |
| L-ebda fluss ta' ilma jew fluss baxx. | Inlet not submerged, air in system, clogged tubing/filter, pump running dry, internal blockage. | Ensure inlet is fully submerged. Check for air leaks in tubing. Clear any blockages in tubing or pump. Do not run dry. |
| Ħsejjes eċċessivi waqt it-tħaddim. | Air in system, pump running dry, vibration from mounting, internal wear. | Check for air in the system. Ensure pump is not running dry. Secure mounting. If noise persists, internal components may be worn. |
| Tnixxijiet mill-konnessjonijiet. | Loose tubing connections, damaged tubing. | Tighten tubing connections. Replace damaged tubing. |
8. Speċifikazzjonijiet
| Parametru | Valur |
|---|---|
| Isem tal-Prodott | Micro Water Pump |
| Ħidma Voltage | DC 12V |
| Kurrenti | Anqas minn 300mA |
| Pressjoni massima | More Than 0.3MPA |
| Fluss tal-Ilma | 1300 ± 50 ml/Min |
| Livell ta' Storbju | 65dB |
| Water Hole Inner Diameter | 4mm (0.16") |
| Total Size (L x Max.D) | 81 x 27mm (3.19" x 1.06") |
| Piż | 65g |
| Kulur Prinċipali | Silver Tone, White |
| Materjal | Metall, Plastik, Lastiku |
| Numru tal-Mudell | a16061400ux0550 |
9. Garanzija u Appoġġ
Specific warranty details for the uxcell DC 12V 300mA 1300ml Water Flow Self Priming Diaphragm Micro Water Pump are not provided in this manual. For warranty information, technical support, or replacement parts, please contact uxcell directly through their official webis-sit jew il-bejjiegħ bl-imnut li mingħandu nxtara l-prodott.