COTEK SP-3000-112

Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter User Manual

Model: SP-3000-112

1. Introduzzjoni

This manual provides essential information for the safe and efficient operation of your Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter. This device converts 12V DC power from batteries into 120V AC power, suitable for a wide range of electronic appliances. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Informazzjoni dwar is-Sigurtà

Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death. Always exercise caution when working with electrical equipment.

Illustration of a battery with a recycling symbol
Always handle batteries with care and ensure proper disposal.
Hard hat, safety glasses, and gloves on a wooden surface
Wear appropriate personal protective equipment during installation and maintenance.

3. Prodott Aktarview

3.1 Karatteristiċi ewlenin

3.2 Inverter Components

Cotek SP-3000-112 Pure Sine Wave Inverter, front-side view
Figura 1: B'mod ġenerali view of the Cotek SP-3000-112 Pure Sine Wave Inverter. This image shows the robust blue and grey casing, ventilation grilles, and the general form factor of the unit.
Rear panel of the Cotek SP-3000-112 Inverter showing AC outlet and controls
Figura 2: Rear panel of the inverter. Visible components include the hardwire AC output terminal, the main power switch (ON/OFF), LED indicators, DIP switches for settings, and an RJ45 port for remote control.
Front panel of the Cotek SP-3000-112 Inverter showing DC input terminals and cooling fan
Figura 3: Front panel of the inverter. This view highlights the heavy-duty DC input terminals (red for positive, black for negative), the chassis ground connection, and the cooling fan vents.
Close-up of the control panel on the Cotek SP-3000-112 Inverter
Figura 4: Dettaljati view of the control panel. This section includes the LED indicators (Power, Fault, Overload), DIP switches for configuration, the RJ45 remote control port, and the green terminal for remote ON/OFF control.

4. Setup u Installazzjoni

Proper installation is crucial for the safe and efficient operation of your inverter. Refer to local electrical codes and standards.

4.1 Tqegħid

4.2 Wajers

All wiring must comply with applicable electrical codes and be performed by a qualified electrician.

  1. L-ertjar: Connect the inverter's chassis ground terminal to a reliable earth ground using appropriate gauge wire.
  2. Konnessjoni tad-Dħul DC:
    • Ensure the battery bank voltage huwa 12VDC.
    • Use appropriately sized cables for the DC input to minimize voltage drop and ensure safety. Refer to cable sizing charts based on current and distance.
    • Connect the positive (+) terminal of the battery bank to the red (+) terminal on the inverter.
    • Connect the negative (-) terminal of the battery bank to the black (-) terminal on the inverter.
    • Install a DC-rated fuse or circuit breaker between the battery bank and the inverter's positive terminal, as close to the battery as possible.
  3. Konnessjoni tal-Output tal-AC:
    • Connect your AC loads to the hardwire AC output terminal block.
    • Ensure the total load does not exceed the inverter's continuous power rating (3000W).
  4. Kontroll mill-bogħod (Mhux obbligatorju): Connect the remote control unit to the RJ45 port or use the green terminal for external ON/OFF control if desired.

5. Istruzzjonijiet Operattivi

5.1 Tixgħel/Jitfi

  1. Biex Tixgħel: Ensure all DC and AC connections are secure. Flip the main power switch on the inverter's rear panel to the 'ON' position. The Power LED indicator should illuminate.
  2. Biex Tifi: Disconnect all AC loads from the inverter. Flip the main power switch to the 'OFF' position.

5.2 Indikaturi LED

The inverter features 3-color LED status indicators on the control panel (refer to Figure 4) to provide operational feedback:

5.3 Issettjar tal-Iswiċċ DIP

The DIP switches on the control panel allow for customization of certain inverter parameters, such as output voltage, frequency, and power saving mode. Refer to the detailed specifications table (Figure 5) or the product datasheet for specific configurations. Always adjust DIP switches when the inverter is powered off.

6. Manutenzjoni

Regular maintenance ensures the longevity and reliable operation of your inverter.

7 Issolvi l-problemi

Din it-taqsima tipprovdi soluzzjonijiet għal kwistjonijiet komuni li tista' tiltaqa' magħhom. Jekk il-problema tippersisti, ikkuntattja l-appoġġ għall-klijenti.

ProblemaKawża PossibbliSoluzzjoni
L-inverter ma jixgħelx.No DC input power; Loose battery connections; Blown DC fuse/breaker; Inverter switch OFF.Iċċekkja l-volum tal-batterijatage; Tighten connections; Replace fuse/reset breaker; Turn inverter switch ON.
L-ebda output AC.Overload; Short circuit; Over-temperature shutdown; Low/High DC input voltage.Reduce AC load; Check for short circuits in wiring/appliances; Allow inverter to cool; Check battery voltage.
Yellow LED illuminated.Vol tal-batterija baxxatage warning; High temperature warning.Recharge batteries; Ensure adequate ventilation, reduce load.
Red LED illuminated / Inverter shut down.Overload; Short circuit; Over-temperature; Under/Over voltage.Identify and correct the fault (e.g., reduce load, fix short, allow cooling, check battery voltage), then restart the inverter.
Cooling fan runs constantly or loudly.High internal temperature due to heavy load or poor ventilation.Reduce load; Improve ventilation around the inverter.

8. Speċifikazzjonijiet

The following table outlines the technical specifications for the Cotek SP-3000 Series Pure Sine Wave Inverter, specifically for the SP-3000-112 model.

Detailed specifications table for Cotek SP-3000 series inverters
Figura 5: Technical specifications for the Cotek SP-3000 Series, including the SP-3000-112 model.
KategorijaParametruSP-3000-112
OutputAC Voltage100 / 110 / 115 / 120VAC ± 5%
Qawwa Rated3000W
Surge Power (1 Sec.)6000W
Qawwa massima tal-Ħruġ (1 Min)3450W
Output WaveformPure Sine Wave (THD<3%)
Frekwenza50 / 60 Hz ±0.5%
InputDC Voltage12VDC
Voltage Firxa10.5 ~ 16.5VDC
Ebda Kurrent tat-Tagħbija<3.0A@12VDC
Modalità Iffrankar tal-Enerġija<0.4A@12VDC
Effiċjenza (Mass.)90%
ProtezzjoniInput Under - Voltage Protezzjoni10.5 ± 0.3VDC
Input Under - Voltage Allarm11.0 ± 0.3VDC
Input Under - Voltage Irkupru12.0 ± 0.3VDC
Input Over - Voltage Protezzjoni16.5 ± 0.3VDC
Input Over - Voltage Irkupru14.5 ± 0.3VDC
Tagħbija żejda tal-outputOutput ta' għeluq voltage, terġa 'tibda biex tirkupra
Output QasirOutput ta' għeluq voltage, terġa 'tibda biex tirkupra
AmbjentTemp operattiv.-20°C ~ +40°C
Ħażna Temp. & Umdità-30°C ~ +70°C, 10 ~ 95% RH
ĠeneraliDimensjonijiet (W x H x D)442 x 214 x 102 mm (17.4 x 8.4 x 4.0 pulzieri)
Piż8.2kg (18.1 lbs)
TkessiħFann li jkessaħ it-temperatura u t-tagħbija kkontrollati
Mechanical drawings with dimensions for Cotek SP-3000 series inverter
Figura 6: Mechanical drawings providing dimensional information for installation planning.

9. Garanzija u Appoġġ

9.1 Informazzjoni dwar Garanzija

The Cotek SP-3000-112 Pure Sine Wave Inverter comes with a Garanzija tal-Manifattur ta' 2 SninDin il-garanzija tkopri difetti fil-materjali u fix-xogħol taħt użu normali. Jekk jogħġbok żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.

9.2 Appoġġ għall-Klijent

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Cotek customer support through their official website or your point of purchase. Provide your model number (SP-3000-112) and a detailed description of the issue to expedite service.

Dokumenti Relatati - SP-3000-112

Preview Manwal tal-Utent tal-Inverter tal-Mewġa Sinusoidali Pura tas-Serje COTEK SP
Manwal komprensiv għall-utent għall-Inverters tal-Mewġa Sinusoidali Pura tas-Serje COTEK SP (SP-700 sa SP-4000). Tgħallem dwar l-installazzjoni, it-tħaddim, is-sigurtà, l-ispeċifikazzjonijiet tekniċi, u l-karatteristiċi avvanzati bħall-output tal-mewġa sinusoidali pura u l-protezzjoni robusta.
Preview Manwal tal-Utent tal-Inverter tal-Mewġa Sinusoidali Pura tas-Serje COTEK SP
Comprehensive user's manual for COTEK SP Series Pure Sine Wave Inverters (SP-700, SP-1000, SP-1500, SP-2000, SP-3000, SP-4000). Covers specifications, installation, operation, safety, and RS-232 communication for reliable power conversion.
Preview Inverter tal-Mewġa Sinusoidali Pura tas-Serje COTEK SPT bi Swiċċ tat-Trasferiment - Introduzzjoni u Speċifikazzjonijiet tal-Prodott
Konċiż fuqview tal-Inverters tal-Mewġa Sinusoidali Pura tas-Serje COTEK SPT bi Swiċċ tat-Trasferiment, li jiddettaljaw l-ispeċifikazzjonijiet tekniċi tagħhom, id-dehra tal-prodott, il-linji gwida tal-installazzjoni, u l-informazzjoni dwar il-garanzija għal diversi mudelli.
Preview COTEK SE Series Pure Sine Wave Inverter User Manual (200W, 350W, 400W)
Comprehensive user manual for the COTEK SE Series Pure Sine Wave Inverters, covering models 200W, 350W, and 400W. This guide provides detailed information on safety precautions, product features, electrical specifications, installation procedures, operation, maintenance, troubleshooting, and warranty details.
Preview COTEK SK Series 1500W Pure Sine Wave Inverter User's Manual
Comprehensive user's manual for the COTEK SK Series 1500W Pure Sine Wave Inverter, covering safety, features, specifications, installation, operation, maintenance, and troubleshooting. Provides detailed guidance for proper use and care.
Preview Manwal tal-Utent tal-Inverter tal-Mewġa Sinusoidali Pura tas-Serje COTEK SK120, SK200, SK350
Dan il-manwal tal-utent jipprovdi informazzjoni dettaljata dwar l-inverters tal-mewġa sinusoidali pura tas-serje COTEK SK120, SK200, u SK350, li jkopri s-sigurtà, il-karatteristiċi, l-installazzjoni, it-tħaddim, is-soluzzjoni tal-problemi, u l-garanzija.