BWT 812195

BWT Aquameter LF Water Filter Meter 3/8" Instruction Manual

Mudell: 812195

Introduzzjoni

The BWT Aquameter LF (Low Flow) is designed to precisely monitor the volume of water that has passed through your water filter system. This device helps ensure timely filter replacement, maintaining optimal water quality for applications such as espresso machines. It features an LCD display for real-time capacity tracking and is compatible with various BWT water filters, including Bestmax and Besttaste series.

Prodott Overview

BWT Aquameter LF control unit and flow sensor

Figura 1: BWT Aquameter LF control unit with LCD display and separate flow sensor, connected by a cable. This image shows the main components of the Aquameter LF system.

BWT Aquameter LF product packaging

Figura 2: The packaging for the BWT Aquameter LF, indicating its 3/8" connection and NSF certification. The packaging also displays the product number 812136 and GTIN 04250266700169.

Setup u Installazzjoni

  1. Ħoll il-Komponenti: Carefully remove the BWT Aquameter LF control unit, flow sensor, and connecting cable from the packaging.
  2. Identify Flow Direction: The flow sensor has an arrow indicating the direction of water flow. Ensure this aligns with your water line.
  3. Connect Flow Sensor: Install the 3/8" flow sensor into the water line before your BWT water filter. Use appropriate plumbing fittings to ensure a secure, leak-free connection.
    BWT Aquameter LF installed with water filter

    Figura 3: The BWT Aquameter LF control unit mounted on a wall, connected to a BWT Bestmax water filter installed under a sink. This illustrates a typical installation setup.

  4. Qabbad l-Unità tal-Kontroll: Plug the cable from the flow sensor into the designated port on the BWT Aquameter LF control unit.
  5. Unità ta' Kontroll tal-Muntanja: Mount the control unit in a convenient location using the provided mounting hardware. Ensure the display is easily visible.
    Close-up of BWT Aquameter LF control unit installed

    Figura 4: A close-up view of the BWT Aquameter LF control unit mounted, showing the LCD display, "PROG." and "RESET" buttons, and the CE mark. The cable connecting to the flow sensor is visible.

  6. Programmazzjoni Inizjali:
    • Press and hold the "PROG." button to enter programming mode.
    • Use the "PROG." button to cycle through settings (e.g., total filter capacity in liters).
    • Use the "RESET" button to adjust the values for each setting.
    • Confirm settings by pressing "PROG." again or waiting for the unit to exit programming mode automatically.
    • Set the filter capacity according to your specific BWT filter model and local water hardness.

Istruzzjonijiet Operattivi

Manutenzjoni

Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Id-displej huwa vojt jew mudlam.Batteriji baxxi jew eżawriti.Contact BWT support for battery replacement.
Capacity not decreasing.Flow sensor incorrectly installed or faulty. No water flow detected.Check flow sensor installation, ensuring correct flow direction. Verify water flow through the system.
Incorrect capacity reading after filter change.Meter not reset after filter replacement.Press and hold the "RESET" button for 3 seconds to reset the meter.
Water leakage at connections.Loose fittings or improper sealing.Ensure all plumbing connections are tight and properly sealed with appropriate thread sealant or tape.

Speċifikazzjonijiet

Informazzjoni dwar Garanzija

For detailed warranty information regarding your BWT Aquameter LF, please refer to the warranty card included with your product or visit the official BWT websit. It-termini u l-kundizzjonijiet tal-garanzija jistgħu jvarjaw skont ir-reġjun.

Appoġġ

If you require further assistance, technical support, or have questions about your BWT Aquameter LF, please contact BWT customer service or visit the official BWT store online.

Visit the BWT Store on Amazon

Dokumenti Relatati - 812195

Preview Manwal tal-Installazzjoni u t-Tħaddim tas-Sistema tal-Filtru tal-Ilma BWT R1 RSF & HWS
Manwal komprensiv għall-installazzjoni, l-ikkummissjonar, it-tħaddim u l-manutenzjoni għas-sistemi tal-filtru tal-ilma BWT R1 RSF u BWT R1 HWS. Jinkludi speċifikazzjonijiet tekniċi, informazzjoni dwar is-soluzzjoni tal-problemi u s-sigurtà.
Preview Manwal tal-Installazzjoni u t-Tħaddim tal-Filtru tal-Punt tad-Dħul BWT Multi C
Dan il-manwal jipprovdi struzzjonijiet għall-installazzjoni u t-tħaddim tal-BWT Multi C Point of Entry Filter, inklużi t-tipi 1000, 2000, u 3000. Ikopri l-ambitu tal-kunsinna, l-użu maħsub, il-funzjoni, il-ħsara fl-enerġija elettrika, il-kundizzjonijiet tal-installazzjoni, is-settings tal-fabbrika, il-proċeduri tal-istartjar, il-manutenzjoni, il-garanzija, ir-responsabbiltajiet tal-operatur, u l-ispeċifikazzjonijiet tekniċi.
Preview Manwal tal-Utent tal-Vacuum tal-Pixxina u Spa Riċarġjabbli BWT FISPA VAC | Tħaddim, Manutenzjoni u Issolvi l-Problemi
Manwal komprensiv għall-utent għall-vacuum cleaner rikarikabbli BWT FISPA VAC għall-pixxini u l-spa. Jinkludi s-setup, it-tħaddim, il-manutenzjoni, twissijiet ta' sigurtà, is-soluzzjoni tal-problemi, u informazzjoni dwar il-garanzija.
Preview BWT Multipur M Backwash Filter Installation and Operating Manual
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the BWT Multipur M backwash filter, covering models DN 65 through DN 150.
Preview BWT pro-soft 11 Istruzzjonijiet ta' Twaħħil u Tħaddim
Gwida komprensiva għall-BWT pro-soft 11 water softener, li tkopri l-installazzjoni, it-tħaddim, il-manutenzjoni, u s-soluzzjoni tal-problemi. Tgħallem kif ittaffi l-provvista tal-ilma domestika tiegħek b'mod effettiv.
Preview BWT In-Line Drinking Water Filter Kit: Installation and Operating Guide
Comprehensive installation, operation, and troubleshooting guide for the BWT In-Line Drinking Water Filter Kit, including specifications, parts, precautions, and maintenance.