Renishaw TP200

Manwal tal-Utent tas-Sonda CMM Renishaw TP200

Model: TP200 | Brand: Renishaw

Introduzzjoni

The Renishaw TP200 is a compact, module-changing probe designed for use with Coordinate Measuring Machines (CMMs). It utilizes advanced strain-gauge mechanisms to provide superior accuracy and extended operational life compared to traditional kinematic touch-trigger probes. The TP200's micro strain gauge transducers ensure excellent repeatability and precise 3D form measurement, even when using long styli. This sensor technology achieves sub-micron repeatability and effectively eliminates the lobing characteristics commonly associated with kinematic probes, making it ideal for high-precision measurement applications.

Kontenut tal-Pakkett

Upon opening the Renishaw TP200 kit, verify that all components are present and undamaged. The standard package typically includes:

Renishaw TP200 CMM Probe kit in its protective case, showing the probe body, two modules, and documentation.

Image: The complete Renishaw TP200 CMM Probe kit, neatly organized within its protective storage case. The image displays the main probe body, two interchangeable modules, and various accompanying documents such as the probe test certificate and cleaning instructions.

Contents of the Renishaw TP200 kit laid out, including the probe, modules, and various certificates and cleaning materials.

Image: All components of the Renishaw TP200 kit are displayed outside their case, including the TP200 probe, two modules, a cleaning kit, and several official Renishaw certificates and product guides.

Setup

Proper setup of the TP200 probe is crucial for accurate measurements. Follow these steps for initial installation and module attachment:

  1. Mounting the Probe Body: Securely attach the TP200 probe body to the CMM's probe head. Ensure the connection is firm and free from any wobble. Refer to your CMM's manual for specific probe head mounting procedures.
  2. Attaching a Module:
    • Select the appropriate TP200 module for your measurement task (e.g., Standard Force for general applications, Extended Force for longer styli).
    • Align the module with the probe body. The module is designed for quick and repeatable magnetic attachment.
    • Gently push the module onto the probe body until it clicks into place, indicating a secure magnetic connection. Do not force the module.
  3. Styli Attachment: Attach the desired stylus to the module. Ensure the stylus is clean and properly threaded or mounted according to its design.
  4. Kalibrazzjoni: Before first use and after any module or stylus change, the probe system must be calibrated on the CMM. Follow your CMM software's calibration routine to ensure accurate measurements.
Close-up of the Renishaw TP200 probe body and two interchangeable modules.

Immaġni: Dettaljata view of the Renishaw TP200 probe body alongside two distinct modules, illustrating their compact design and the magnetic interface for quick attachment.

Qiegħ view of the TP200 probe and modules, showing the contact points and magnetic interfaces.

Image: An underside perspective of the TP200 probe and its modules, highlighting the precision-engineered contact points and the magnetic coupling mechanism that facilitates secure and repeatable module changes.

Operazzjoni

The Renishaw TP200 probe operates by detecting contact with a workpiece surface. Its strain-gauge technology provides highly accurate trigger signals, enabling precise measurement.

Basic Measurement Principles:

Module Changing:

The TP200's module-changing capability allows for rapid exchange of modules without re-qualification, provided the system is properly calibrated. This is typically performed using an automated rack system on the CMM.

  1. Automated Change: If your CMM is equipped with a module changing rack (e.g., MCR20), program the CMM to automatically deposit the current module and pick up the desired one.
  2. Manual Change: To manually change a module, gently pull the current module straight off the probe body. Then, align the new module and push it onto the probe body until it magnetically locks into place.

Always ensure the probe and modules are clean before and after operation to maintain optimal performance.

Manutenzjoni

Regular maintenance ensures the longevity and accuracy of your Renishaw TP200 probe system.

Tindif:

Ħażna:

When not in use, store the TP200 probe body and modules in their original protective case. This protects them from dust, debris, and physical damage.

Closed black protective case with the gold Renishaw logo.

Image: The closed protective case for the Renishaw TP200 probe, featuring the prominent gold Renishaw logo, emphasizing its role in safe storage.

Issolvi l-problemi

This section addresses common issues you might encounter with the Renishaw TP200 probe.

ProblemaKawża PossibbliSoluzzjoni
Inconsistent Triggering / Poor RepeatabilityDirty stylus or module interface; Loose stylus; Probe not properly calibrated; Environmental vibrations.Clean stylus and module contacts. Ensure stylus is securely attached. Perform a full probe calibration. Check for and mitigate external vibrations.
Module Not Attaching SecurelyDebris on magnetic contacts; Damaged module or probe body interface.Clean magnetic contact surfaces thoroughly. Inspect for physical damage; if damaged, contact Renishaw support.
CMM Not Recognizing ProbeIncorrect wiring/connection to CMM; Software configuration error; Probe head issue.Verify all cables are securely connected. Check CMM software settings for probe configuration. Consult CMM manual or support.

For issues not listed here or if solutions do not resolve the problem, please contact Renishaw technical support.

Speċifikazzjonijiet

Key technical specifications for the Renishaw TP200 CMM Probe:

Note: For detailed and precise specifications, always refer to the official Renishaw TP200 product datasheet or user guide provided with your purchase.

Garanzija u Appoġġ

Renishaw products are manufactured to high standards and are backed by a comprehensive warranty. The product information indicates a 3-year warranty is available for your Renishaw product, provided it is registered within the first 3 months of use.

Renishaw Official Websit: www.renishaw.com
CMM Product Guides: www.renishaw.com/cmmguides
Extended Warranty Information: www.renishaw.com/ew

Always provide your product model (TP200) and serial number (if applicable) when contacting support for faster service.

Dokumenti Relatati - TP200

Preview Surface Finish Probe Installation and User's Guide - Renishaw SFP1
Comprehensive installation and user guide for the Renishaw SFP1 surface finish probe, detailing setup, operation, safety, and technical specifications for use with the REVO system.
Preview Gwida ta' Bidu Mgħaġġel tar-Renishaw RMP60
Gwida ta' bidu rapidu għas-sonda tar-radju Renishaw RMP60, li tiddettalja s-setup u t-tħaddim inizjali għall-ispezzjoni tal-għodda tal-magni.
Preview Renishaw SP80 and SP80H User's Guide: High-Accuracy Scanning Probes for CMMs
Explore the Renishaw SP80 and SP80H ultra-high accuracy scanning probes. This comprehensive user guide covers features, specifications, operation, stylus selection, and maintenance for advanced CMM metrology applications.
Preview UCC T3-2 Installation Guide
Comprehensive guide for installing, connecting, and configuring the Renishaw UCC T3-2 Coordinate Measuring Machine (CMM) controller, covering hardware setup, software installation, networking, and safety.
Preview Modulu tas-Sonda tal-Finitura tal-Wiċċ Renishaw SFM-B3 - Kapaċità ta' Kejl Imtejba
Speċifikazzjonijiet u karatteristiċi dettaljati tal-modulu tas-sonda tal-irfinar tal-wiċċ Renishaw SFM-B3, iddisinjat għal aċċess u spezzjoni mtejba f'ambjenti ta' manifattura ta' preċiżjoni bis-sistema REVO®.
Preview Gwida għall-Installazzjoni tas-Sonda tal-Magna Ottika Renishaw OMP40-2
Din il-gwida tipprovdi dettalji komprensivi dwar l-installazzjoni, is-setup u l-konfigurazzjoni għas-sonda ottika tal-magna Renishaw OMP40-2, komponent ewlieni għall-ispezzjoni awtomatizzata tal-biċċiet tax-xogħol u s-setup tax-xogħol f'ambjenti tal-magni CNC.