This manual provides detailed instructions for the installation, operation, and maintenance of your American Lighting LED Complete 2 Under Cabinet Fixture, model ALC2-32-WH. This 32-inch, 120-Volt dimmable fixture provides warm white LED lighting with a low-profile design, ideal for various indoor applications.

Image 1.1: American Lighting LED Complete 2 Under Cabinet Fixture (ALC2-32-WH).
2. Informazzjoni Importanti dwar is-Sigurtà
WARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, current electrical codes, and/or the current National Electrical Code (NEC).
- Aqra l-istruzzjonijiet kollha qabel tibda. Ħlief dawn l-istruzzjonijiet għall-użu fil-futur.
- Biex tnaqqas ir-riskju ta’ nar, xokk elettriku, jew korriment lil persuni, oqgħod attent ħafna għal dan il-manwal u żomm fil-linji gwida tiegħu meta tuża dan il-prodott.
- ATTENZJONI: To reduce the risk of electric shock or injury to persons, do not operate fixture with missing or damaged lens or wiring compartment cover.
- ATTENZJONI: To reduce the risk of electric shock or injuries to persons, do not operate without end connector cover(s) in place for any molex ports/connectors not in use.
- WARNING CAUTION: RISKJU TA' NAR: Żomm l-attrezzaturi 'l bogħod minn purtieri u materjali kombustibbli oħra.
- Adattat għal postijiet niexfa fuq ġewwa biss.
- Do not exceed the maximum load of 400 watts when interconnecting fixtures.
- Mhux maħsub għall-installazzjoni minquxa fis-soqfa jew is-suffett.
- LEDs huma jleqqu! Tħarisx direttament lejn is-sors tad-dawl LED.
- Tmissx LEDs.
- M'hemm l-ebda partijiet li jistgħu jintużaw ġewwa l-modulu LED.
- Għat-tindif, uża artab, niexef jew damp drapp. Tużax kimiċi ħarxa jew abrażivi.
3. Setup u Installazzjoni
The LED Complete 2 fixture can be hardwired directly via a rear access door, or hardwired indirectly via the Hardwire Junction Box (sold separately), or powered by a 120V receptacle (power cord sold separately). Multiple fixtures can be linked together.
3.1 Immuntar tal-Fitture
- Iddetermina l-postijiet għal kull apparat. Għal installazzjonijiet b'wajers fissi, qabbad il-wajers tal-provvista permezz ta' knockouts qabel l-immuntar.
- Uża tornavit Phillips jew driver bit biex tissikka l-viti tal-immuntar captive u twaħħal l-apparat ma' wiċċ ta' mmuntar xieraq.

Image 3.1: Mounting and Interconnecting options for the fixture.
3.2 Connecting Power via Rear Access Door (Direct Wire)
This method is for direct hardwire installations where the wiring enters the fixture through the rear access door.
- Remove the rear access door located in the center of the back of the fixture housing.
- Punch out knockout, then loosen screw that secures rear access door.
- Using a 3/8" cable connector (not included), supply wire (14AWG or 12AWG wire) through the knockout.
- Strip back jacket on supply wires to 3/8" and use push-in connectors to wire the fixture: Black to Black (Hot), White to White (Neutral), Green/Yellow to Bare Wire (Ground).
- Replace rear access door and tighten retaining screw.

Image 3.2: Wiring through the rear access door.
3.3 Connecting Power via Hardwire Junction Box (ALC-BOX)
For installations requiring a junction box (sold separately), follow these steps:
- Turn off power at the electrical service panel.
- Remove junction box cover and screws.
- Prepare flat, non-metallic cable (NM-2C+Ground) or armored cable (BX) by stripping conductor ends approximately 3/8".
- For installation, mount the junction box to the wall.
- Affix the junction box to the underside of the cabinet with captive screws provided.
- Connect supply wires to the push-in connectors inside the junction box: Black to Hot, White to Neutral, Green to Ground.
- Insert the jumper cord (sold separately) or direct end-to-end connector (supplied with fixture) into the appropriate electrical port of the wire junction box.
- Ensure all fixtures connected to the junction box are properly installed and all open electrical ports on the module ends and fixtures are safely covered.
- Restore circuit power at the electrical service panel.

Image 3.3: Direct wire junction box installation diagram.
3.4 Interconnecting Multiple Fixtures
Multiple fixtures can be linked together using linking cables or inline connectors (sold separately).
- Via Linking Cable: To interconnect nearby fixtures, remove the adjacent port covers and utilize the ALC-EX linking cable (sold separately) to connect.
- Via End-to-End Connector: To interconnect fixtures directly to each other, use the in-line connector (included with each fixture) by removing adjacent port covers and inserting fully.
4. Istruzzjonijiet Operattivi
The American Lighting LED Complete 2 fixture is dimmable. To operate the dimming function, connect the fixture to a compatible 120V dimmer switch (sold separately). The fixture supports 5-100% dimming with most standard 2-wire and CL dimmers.
4.1 Compatible Dimmers
For optimal performance, use dimmers compatible with LED lighting. Examples of compatible dimmers include:
- Lutron Diva DVCL-153P (Universal CFL/LED/Incandescent)
- Lutron Diva DVELV-300P (Electronic Low Voltage (ELV))
- Lutron Sureslide 6613 (Magnetic Low Voltage (MLV))
Note: Dimmer performance may vary. Always refer to the dimmer manufacturer's instructions for more detailed information regarding performance and compatibility.
5. Manutenzjoni
The LED Complete 2 fixture requires minimal maintenance. Ensure power is off before any cleaning or inspection.
- Tindif: Uża artab, niexef, jew ftit damp cloth to clean the exterior of the fixture. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish or electrical components.
- Modulu LED: The LED module is non-removable and contains no serviceable parts. Do not attempt to open or repair the LED module.
- Lenti: The full-length acrylic lens diffuses light evenly. Keep the lens clean for optimal light output.
6 Issolvi l-problemi
If you experience issues with your LED Complete 2 fixture, consult the following troubleshooting guide:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-apparat ma jixgħelx | L-ebda qawwa għall-apparat. Konnessjoni tal-wajers sfużi. Faulty switch or dimmer. | Iċċekkja s-circuit breaker u s-swiċċ tal-ħajt. Iċċekkja li l-konnessjonijiet tal-wajers kollha huma siguri. Test switch/dimmer with another device or replace if necessary. |
| Id-dawl jitteptep jew jitbaxxa b'mod inkonsistenti | Swiċċ tad-dimmer inkompatibbli. Wiring maħlul. Ċirkwit mgħobbi żżejjed. | Ensure a compatible LED dimmer is used. Iċċekkja l-konnessjonijiet kollha tal-wajers. Reduce the number of fixtures on the circuit or consult an electrician. |
| Fixture is not dimming | Non-dimmable switch used. Dimmer inkompatibbli. | Replace with a compatible dimmable switch. Refer to the list of compatible dimmers in Section 4.1. |
| One fixture in a linked series is off | Loose linking cable/connector. Faulty fixture. | Check the connection between the fixtures. If other fixtures in the series work, the individual fixture may be faulty and require replacement. |
7. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Mudell | ALC2-32-WH |
| Input Voltage | 120 Volt AC, 60Hz |
| Wattage | 11 watt |
| Output tad-Dawl | 781 Lumens |
| Effiċjenza | 71 lumens għal kull watt |
| Temperatura tal-Kulur (CCT) | 3000 Kelvin (abjad sħun) |
| Indiċi tar-Rendiment tal-Kulur (CRI) | 90+ |
| Dimmable | Yes (5-100% with compatible dimmers) |
| Ħajja Rated | 35,000 sigħat |
| Materjal | Powder Coated Aluminum Housing, Acrylic Lens |
| Dimensjonijiet (L x W x H) | 32.75 x 4 x 0.94 pulzieri |
| Piż tal-oġġett | 1.99 liri |
| Tip ta 'Immuntar | Under Cabinet, Surface Mount |
| Ċertifikazzjonijiet | cETLus Listed (dry locations), Energy Star certified |
8. Garanzija u Appoġġ
8.1 Garanzija Limitata tal-Prodott
This product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e., replacement of defective electronic components) or replaced (i.e., new fixture, lamp, socket, excluding the lamp) or replaced, at the discretion of American Lighting, Inc. Claims for defective products must be made to the retail location from which the product was purchased with warranty. Upon submission of proper return claim documentation and product to American Lighting, Inc. by the retailer, American Lighting, Inc. reserves the right to inspect the product for misuse or abuse. Claims for consequential damages or damages that are not directly American Lighting, Inc. will be denied. This is a warranty of product reliability only and not a warranty of merchantability or fitness for a particular purpose. American Lighting, Inc. disclaims all liability whatsoever for any special, incidental or consequential damages, including without limitations, installations costs and damages for personal injury and property. These products may represent a possible shock or fire hazard if improperly installed or attached in any way. This warranty applies only to products that have been installed in accordance with instruction sheet and current local codes and/or the National Electrical Code. Warranty does not apply to any product that has been improperly installed or in situations where components have been altered in any way.
8.2 Appoġġ għall-Klijent
For questions, comments, technical assistance or additional repair parts, please contact American Lighting customer service. Refer to the official American Lighting website for contact information or visit their Ħanut tal-Marka Amazon.