Introduzzjoni
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your American Lighting LED Complete 2 Under Cabinet Fixture. This 120-Volt dimmable warm white LED fixture is designed for efficient and uniform lighting in various indoor applications.

Image: The American Lighting LED Complete 2 Under Cabinet Fixture, a white, rectangular LED light bar with a switch on the front, designed for under-cabinet installation.
Informazzjoni Importanti dwar is-Sigurtà
TWISSIJA:
- Aqra l-istruzzjonijiet kollha qabel tibda l-installazzjoni.
- This product may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, current electrical codes, and/or the current National Electric Code (NEC).
- Biex tnaqqas ir-riskju ta’ nar, xokk elettriku, jew korriment lil persuni, oqgħod attent ħafna għal dan il-manwal u żomm fil-linji gwida tiegħu meta tuża dan il-prodott.
- Żgura li l-voltagIl-provvista tal-enerġija tiegħek hija kompatibbli (120V AC).
- Taqbiżx 5 AMPTagħbija massima S.
- Għall-użu biss ma' provvista tal-enerġija ta' 120V 60Hz.
- Wiring must be completed before mounting.
- All fixtures connected to junction box must be mounted.
- Do not install in wet environments. For indoor, dry location use only.
- Elettriċisti kwalifikati skont il-kodiċijiet elettriċi lokali għandhom iwettqu l-installazzjonijiet kollha.
- Dimmers approvati mill-UL jistgħu jintużaw mal-attrezzaturi taħt il-kabinett li jistgħu jitbaxxew bl-LED Complete (Serje ALC).
- Dan il-prodott huwa adattat għall-użu f'ċirkwiti ta' dimming.
- Dejjem skonnettja l-enerġija elettrika tal-prodott qabel ma tnaddaf jew tpoġġi jew tneħħi partijiet.
- Tħaddimx dan il-prodott jekk il-kejbil tal-jumper ikun bil-ħsara.
- Żomm il-kejbil tal-jumper 'il bogħod minn sorsi ta' sħana u uċuħ imsaħħna.
- Tħaddimx dan il-prodott f'ambjenti fejn qed jintużaw sprejs tal-ajrusol jew fejn qed jingħata l-ossiġnu.
- Għat-tindif, uża drapp artab u niexefamp drapp. Tużax kimiċi ħarxa jew abrażivi.
ATTENZJONI:
- To reduce the risk of electric shock, do not use this junction box or jumper cables for the ALC series (part numbers ALC-length-color) to provide power to any products other than the LED Complete fixtures (ALC Series).
- To reduce the risk of fire, electric shock, or injury to persons, do not operate fixture with missing or damaged lens or wiring compartment cover.
- To reduce the risk of electric shock or injury to persons, do not operate without end connector cover(s) in place for any molex ports/connectors not in use.
- Mhux maħsub għall-installazzjoni minquxa fis-soqfa jew is-suffett.
- LEDs huma jleqqu! Tħarisx direttament lejn is-sors tad-dawl LED.
- Tmissx LEDs.
- M'hemm l-ebda partijiet li jistgħu jintużaw ġewwa l-modulu LED.

Image: A page from the installation instructions detailing important safety information, warnings, and pre-installation notes for the LED Complete 2 series.
Setup u Installazzjoni
The American Lighting LED Complete 2 fixture offers flexible installation options, including direct wire and linking multiple units.
Immuntar tal-Fitture
- Iddetermina l-postijiet għal kull apparat. Għal installazzjonijiet b'wajers fissi, qabbad il-wajers tal-provvista permezz ta' knockouts qabel l-immuntar.
- Uża tornavit Phillips jew driver bit biex tissikka l-viti tal-immuntar captive u twaħħal l-apparat ma' wiċċ ta' mmuntar xieraq.

Image: Diagram showing the mounting points and rear access door of the fixture. It illustrates how to secure the fixture to a surface using screws.
Connecting Power via Rear Access Door
This method is used for hardwiring the fixture directly to a power source.
- The rear access door is located in the center of the back of the fixture housing. It has its own knockout for quick connection to supply wires, foregoing the need to remove the lens cover and open the wiring compartment.
- Neħħi l-knockout billi tuża martell jew punch, imbagħad ħoll il-kamin li jiżgura l-bieba tal-aċċess ta' wara billi tuża tornavit Phillips jew driver bit.
- Install the 3/8" cable connector (included) for the supply wire following National Electric Code and local codes through this knockout on the access door. Ensure to use 14AWG or 12AWG wire. AC should be protected by circuit breaker or fuse.
- Strip back jacket on supply wires to 3/8" and use push-in connectors inside housing to connect the wires, matching polarity (Black=Black, Hot; White=White, Neutral; Yellow/Green=Bare Wire = Ground) through knockout so that push-in connectors are positioned on the housing side of the access door.
- Ibdel il-bieb ta' aċċess ta' wara u issikka l-kamin li jżomm. Kun żgur li l-wajers ma jiġux maqrusa jew imħassra minn xi parti tal-housing jew l-għata.

Image: Detailed diagram illustrating the rear access door, knockout, and push-in wire connectors for hardwiring the fixture. It shows how to connect the electrical wires securely.
Interconnecting Fixtures
Multiple fixtures can be linked together for continuous lighting.
Interconnecting via Linking/Jumper Cable
- To interconnect nearby fixtures, remove the adjacent port covers and utilize the ALC-EX linking cable (sold separately).
- If needed, linking cables can be interconnected to make longer lengths.

Image: Diagram showing how to link multiple LED Complete 2 fixtures using an inline connector or jumper cable. It illustrates the connection points on the side of the fixtures.
Interconnecting via End-to-End Linking
Biex tqabbad l-attrezzaturi direttament ma' xulxin (minn tarf sa tarf), uża l-konnettur in-line (inkluż ma' kull apparat) billi tneħħi l-għata tal-portijiet ta' maġenb xulxin u ddaħħalhom kompletament.
Direct Wire Junction Box Installation (for ALC-BOX-##)
Dan it-tip ta 'installazzjoni huwa inqas komuni u tipikament isir biss meta l-bieb ta' aċċess ta 'wara ma jistax jiġi utilizzat.
- Open wiring compartment by removing screws and open the end of the fixture cover from housing body.
- Punch out whichever knockout is best suited for connection to 120V supply wire.
- Install cable connector and connect fixture wires following National Electric Code and/or local building code requirements. Minimum 18AWG solid copper wire. AC lead should be 120V protected by circuit breaker or fuse.
- Waħħal il-linja voltage supply wires to fixture lead wires with wire nuts/WAGO. White to White/Neutral and Yellow/Green (Ground) to Green or bare wire inside the fixture. Secure each connection using push-in wire connectors provided on the fixture lead wire. If your system has no ground wire, consult a qualified electrician before proceeding with the installation.
- Tinstallax f'ambjent imxarrab.
- Erġa' poġġi l-għatu tal-kompartiment tal-wajers, billi twaħħlu bil-viti taż-żamma eżistenti. Nota: Kun żgur li l-wajers ma jkunux maqbudin jew imħassra minn xi parti tal-housing jew tal-għatu.
- Follow directions above for mounting fixture.

Image: Diagram detailing the direct wire junction box installation for the LED Complete 2 fixture. It shows the components like the junction box, electrical port, and push-in connectors, along with wiring instructions.
Istruzzjonijiet Operattivi
Tixgħel/Jitfi
The fixture is equipped with a switch for basic on/off control. For hardwired installations, the fixture will operate via the wall switch connected to the circuit.
Dimming
The American Lighting LED Complete 2 fixture is dimmable. Use a compatible 120V dimmer switch (UL approved) for optimal performance. Refer to the "Compatible Dimmers" section for recommended models.

Image: A page from the product information showing recommended power supplies, accessories, and a table of compatible dimmers from various brands, including model numbers and dimming ranges.
Manutenzjoni
Tindif
To clean the fixture, ensure power is disconnected. Use a soft, dry, or slightly damp cloth. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the finish or electrical components.
Modulu LED
The LED module within this fixture is not user-serviceable. Do not attempt to open or repair the LED module.
Issolvi l-problemi
If your American Lighting LED Complete 2 fixture is not functioning as expected, please review il-kwistjonijiet u s-soluzzjonijiet komuni li ġejjin:
- Fixture does not light up:
- Iċċekkja jekk il-provvista tal-enerġija hijiex imqabbda u jekk is-circuit breaker hu mixgħul.
- Ensure all wiring connections are secure and correct, especially for hardwired installations.
- Verify that the fixture's on/off switch (if present) is in the "on" position.
- Ikkonferma li l-voltage supplied is 120V AC.
- L-output tad-dawl mhux konsistenti jew jitteptep:
- Ensure a compatible dimmer switch is being used. Incompatible dimmers can cause flickering or poor dimming performance.
- Iċċekkja għal konnessjonijiet tal-wajers laxki.
- L-apparat huwa mħassar:
- If the lens or wiring compartment cover is missing or damaged, discontinue use and contact customer support.
- Do not operate if the jumper cable is damaged.
If these steps do not resolve the issue, please contact American Lighting customer support.
Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Numru tal-Mudell | ALC2-12-WH |
| Input Voltage | 120V AC, 60Hz |
| Wattage | 4 watt |
| Luminożità | 273 Lumens |
| Temperatura tal-Kulur (CCT) | 3000K (abjad sħun) |
| Indiċi tar-Rendiment tal-Kulur (CRI) | 90+ |
| Dimmable | Yes (with compatible 120V dimmers) |
| Ħajja Rated | 35,000 sigħat |
| Dimensjonijiet (L x W x H) | 12.25 x 4 x 0.94 pulzieri |
| Materjal | Djar tal-Aluminju Miksi bit-Trab, Lenti Akrilika |
| Tip ta 'Immuntar | Surface Mounted, Under Cabinet |
| Użu fuq ġewwa/barra | Użu fuq ġewwa biss |
| Ċertifikazzjonijiet | cETLus Listed (dry location), ENERGY STAR certified |

Image: A page from the product brochure detailing technical specifications for the LED Complete 2 series, including input voltage, CCT, CRI, wattage, lumens, and rated life.
Garanzija
This American Lighting product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e. replacement of defective electronic parts) or, at the discretion of American Lighting, Inc., exchanged for a new or reconditioned product.
This warranty does not cover damage due to improper installation, accident, abuse, misuse, or normal wear and tear. It also does not cover incidental or consequential damages.
For complete warranty terms and conditions, please refer to the official American Lighting websit jew ikkuntattja l-appoġġ tal-klijent.
Appoġġ għall-Klijent
For technical assistance, warranty claims, or additional information, please contact American Lighting:
- Websit: www.americanlighting.com
- Indirizz: 11775 E. 45th Ave Denver, CO 80239
- Telefon: 1-800-880-1180