Eaton CHB120

Eaton Cutler-Hammer CHB120 Circuit Breaker User Manual

Model: CHB120

1. Introduzzjoni

This manual provides essential information for the safe and proper installation, operation, and maintenance of the Eaton Cutler-Hammer CHB120 1-Pole 20A Circuit Breaker. This device is designed to protect electrical circuits from overcurrents and short circuits, ensuring the safety of your electrical system and connected equipment. Please read this manual thoroughly before any installation or operation.

2. Informazzjoni dwar is-Sigurtà

TWISSIJA: Electrical shock hazard. Improper installation or maintenance can result in serious injury or death. All work on electrical systems should be performed by qualified personnel only. Always disconnect power at the main service panel before working on or near circuit breakers.

  • Ensure all power is OFF before installation or servicing.
  • Uża tagħmir protettiv personali (PPE) xieraq.
  • Ivverifika voltagIl-klassifikazzjonijiet e u attwali jaqblu mal-applikazzjoni tiegħek.
  • Do not use damaged circuit breakers.
  • Segwi l-kodiċijiet elettriċi lokali u nazzjonali kollha.

3. Karatteristiċi tal-prodott

  • Mudell: CHB120
  • Poli: 1 Pol
  • Voltage Rating: 120 / 240 volt
  • Klassifikazzjoni kurrenti: 20 Amp
  • Klassifikazzjoni ta' Interruzzjoni: 10kA@120V
  • Tip: Circuit Breaker Standard
  • Immuntar: Immonta fuq il-Panew

4. Speċifikazzjonijiet

SpeċifikazzjoniValur
BrandEaton
Numru tal-MudellCHB120
Klassifikazzjoni kurrenti20 Amps
VoltagKlassifikazzjoni e120/240 Volts
Numru ta 'Pollakki1
Tip ta 'Circuit BreakerStandard
Tip ta 'ImmuntarImmonta fuq il-Panew
Interruzzjoni tal-Klassifikazzjoni10kA@120V
Dimensjonijiet tal-Prodott7 x 7 x 7 pulzieri (approssimattiv)
Piż tal-oġġett7 liri (madwar)
UPC704798904778

5. Installazzjoni

Installation of circuit breakers should only be performed by a qualified electrician in accordance with all applicable electrical codes and standards. The following steps are for informational purposes only and do not substitute for professional expertise.

  1. Skonnettja l-Enerġija: Turn off the main power supply to the electrical panel at the utility meter or main disconnect. Verify power is off using a voltagtester.
  2. Remove Panel Cover: Neħħi bir-reqqa l-għatu tal-pannell elettriku.
  3. Identifika s-Slott: Locate an available slot on the bus bar for the 1-pole CHB120 circuit breaker.
  4. Installa l-Interruttur: Hook the rear of the circuit breaker onto the retaining clip on the panel's bus bar. Press the front of the breaker firmly until it snaps into place.
  5. Qabbad il-Wiring: Connect the circuit wire (hot wire) to the terminal screw on the circuit breaker. Ensure the wire is properly stripped and the screw is tightened to the manufacturer's specified torque.
  6. Replace Panel Cover: Once all connections are secure and verified, replace the electrical panel cover.
  7. Irrestawra l-Enerġija: Erġa' ixgħel il-provvista tal-enerġija prinċipali.
Eaton Cutler-Hammer CHB120 1-Pole 20A Circuit Breaker

Figure 1: Eaton Cutler-Hammer CHB120 1-Pole 20A Circuit Breaker. This image displays the Eaton Cutler-Hammer CHB120 circuit breaker, a single-pole device with a 20 Amp rating. It features a white toggle switch for ON/OFF/TRIPPED states and screw terminals for electrical connections. The model number 'CHB120' is visible on the label.

6. Operazzjoni

The CHB120 circuit breaker has three primary positions for its toggle switch:

  • FUQ: The circuit is energized, and power is flowing. The toggle is typically pushed fully towards the "ON" marking.
  • MITFI: The circuit is de-energized, and power is interrupted. The toggle is typically pushed fully towards the "OFF" marking.
  • TRIPPED: When an overcurrent or short circuit occurs, the breaker automatically trips to protect the circuit. The toggle will move to an intermediate position, usually between ON and OFF. To reset a tripped breaker, first push the toggle firmly to the full OFF position, then push it to the full ON position.

7. Manutenzjoni

Circuit breakers generally require minimal maintenance. However, periodic visual inspection is recommended:

  • Inspect for any signs of physical damage, discoloration, or burning.
  • Ensure all connections are tight. (TWISSIJA: Disconnect power before checking connections).
  • Keep the electrical panel area clean and free from obstructions.

8 Issolvi l-problemi

If your CHB120 circuit breaker frequently trips, consider the following:

  • Overloaded Circuit: The most common cause of tripping. Disconnect some appliances or devices from the circuit to reduce the load.
  • Short Circuit: A direct connection between hot and neutral/ground wires can cause a trip. Inspect wiring and connected devices for damage.
  • Ħsara fl-Art: If current leaks to the ground, it can cause a trip (though this breaker is not a GFCI).
  • Faulty Appliance/Device: A malfunctioning appliance connected to the circuit can cause repeated tripping. Unplug devices one by one to identify the culprit.
  • Faulty Breaker: In rare cases, the circuit breaker itself may be defective. If all other causes are ruled out, consult a qualified electrician for inspection and potential replacement.

If you are unable to resolve the issue, contact a qualified electrician.

9. Garanzija u Appoġġ

Specific warranty information for the Eaton Cutler-Hammer CHB120 circuit breaker is typically provided at the point of purchase or included with the product packaging. For detailed warranty terms, technical support, or service inquiries, please refer to the official Eaton website or contact Eaton customer service directly.

You can visit the Eaton websit għal aktar informazzjoni: www.eaton.com

Dokumenti Relatati - CHB120

Preview Manwal tal-Utent tas-Salvavita taċ-Ċirkwit Eaton Magnum LV-Air (1812.900A)
Manwal komprensiv għall-utent għall-Eaton Magnum LV-Air Circuit Breaker (mudell 1812.900A), li jagħti dettalji dwar l-installazzjoni, it-tħaddim, il-manutenzjoni, is-soluzzjoni tal-problemi, u l-partijiet tat-tiġdid. Ikopri konfigurazzjonijiet fissi u drawout b'sistemi elettroniċi ta' tripping.
Preview 伊顿新一代空气断路器 IZM9 系列:卓越的解决方案
了解伊顿新一代 IZM9 系列空气断路器,为全球电力系统提供创新、可靠且高效的动力管理解决方案。该系列产品凭借先进的 PXR 电子脱扣平台、增强的安全特性(如 ARMS 闪弧减少维护系统)以及强大的通讯能力,广泛应用于建筑、信息技术、工业机械和能源公用事业等多个领域,满足客户日益增长和多样化的需求。
Preview Istruzzjonijiet għall-Installazzjoni u t-Tħaddim tas-Salvavita tal-Vakwu Eaton E-VAC HV
Din il-gwida tipprovdi dettalji essenzjali dwar l-installazzjoni, it-tħaddim, il-manutenzjoni, u d-dettalji tekniċi għall-Eaton E-VAC Enclosed Indoor High Voltage Vacuum Circuit Breaker (Mudell IL550-0501001E), li jiżgura użu sikur u effiċjenti f'applikazzjonijiet industrijali u tal-grilja tal-enerġija.
Preview Salvaviti tas-Serje Eaton G & C f'Kaxxa Mmudellata: 15-2500A UL, CSA, IEC
Katalogu komprensiv li jagħti dettalji dwar is-Salvaviti taċ-Ċirkwiti f'Kaxxa Mdewba (MCCBs) tas-Serje Cutler-Hammer tas-Serje G u tas-Serje C ta' Eaton. Ikopri l-ispeċifikazzjonijiet tal-prodott, il-karatteristiċi elettriċi, l-applikazzjonijiet, u l-gwidi tal-għażla għal salvaviti li jvarjaw minn 15 sa 2500. amperes, konformi mal-istandards UL, CSA, u IEC.
Preview EATON 11/25 IL019140ZU Fuljett ta' Istruzzjonijiet: Gwida għall-Installazzjoni ta' RCCB u RCBO
Istruzzjonijiet dettaljati għall-installazzjoni u speċifikazzjonijiet tekniċi għas-serje EATON PL6, PL7, HN, PF6, PF7, u HNC Residual Current Circuit Breakers (RCCBs) u Residual Current Breakers bi Protezzjoni minn Kurrent Żejjed (RCBOs), inklużi dijagrammi tal-wajers u dejta elettrika.
Preview Gwida għall-Għażla Sikura ta' Eaton Power: Soluzzjonijiet ta' Circuit Breakers u Kontroll tal-Muturi
Skopri l-Gwida komprensiva tal-Għażla ta' Power Secure ta' Eaton, li tinkludi Air Circuit Breakers (Serje PSL), Molded Case Circuit Breakers (Serje PDC, BZM), Miniature Circuit Breakers (Serje E6X), u Serje D-Line għall-Kontroll u l-Protezzjoni tal-Muturi. Sib speċifikazzjonijiet dettaljati tal-prodott, dejta teknika, u informazzjoni dwar l-għażla għall-ħtiġijiet tad-distribuzzjoni u l-protezzjoni tal-elettriku.