This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Parker 201579 Bolt Flange Kit. Adherence to these guidelines is crucial for ensuring the proper function, longevity, and safety of the assembled system. Please read this manual thoroughly before proceeding with any installation or maintenance procedures.

The Parker 201579 Bolt Flange Kit is designed for specific industrial applications requiring secure flange connections. Proper installation is critical to prevent leaks and ensure structural integrity.

2. Kontenut tal-Pakkett

Upon opening the package, verify that all components of the Parker 201579 Bolt Flange Kit are present and undamaged. The kit typically includes the following items:

  • Bolts (threaded fasteners)
  • Nuts (mating fasteners for bolts)
  • Washers (if applicable, for load distribution and vibration dampening)
Parker 201579 Bolt Flange Kit in original packaging

Figura 2.1: The Parker 201579 Bolt Flange Kit as received in its sealed plastic bag, showing the Parker branding and model number label.

Close-up of bolts and nuts from Parker 201579 Bolt Flange Kit

Figura 2.2: A eqreb view of the components within the Parker 201579 Bolt Flange Kit, clearly showing the bolts and nuts, which are typically made of galvanized or similarly coated steel for corrosion resistance.

3. Setup u Installazzjoni

Proper installation is paramount for the integrity of the flange connection. Always refer to the specific flange assembly instructions provided by the equipment manufacturer for torque specifications and bolt patterns.

  1. Preparazzjoni: Ensure that the flange surfaces are clean, free from debris, and undamaged. Inspect the bolts, nuts, and washers (if included) for any defects.
  2. Allinjament: Carefully align the two flanges to be joined, ensuring that the bolt holes are concentric.
  3. Tqegħid tal-Gasket: If a gasket is required, place it correctly between the flange faces. Ensure it is properly seated and not pinched.
  4. Bolt Insertion: Insert the bolts through the flange holes. If washers are used, place them under the nut and/or bolt head as specified by the application.
  5. Nut Engagement: Hand-tighten the nuts onto the bolts. Ensure sufficient thread engagement.
  6. Torquing Sequence: Follow a star or cross-pattern sequence for tightening the bolts to ensure even compression of the gasket and uniform load distribution across the flange. Tighten in stages (e.g., 30%, 60%, 100% of final torque).
  7. Torque Finali: Use a calibrated torque wrench to apply the manufacturer's specified torque to each bolt. Do not overtighten, as this can damage the bolts, nuts, or flange, leading to failure.

Safety Note: Always wear appropriate personal protective equipment (PPE) during installation, including gloves and eye protection. Consult relevant safety data sheets and local regulations.

4. Konsiderazzjonijiet Operattivi

Once installed, the bolt flange connection is typically static. However, certain operational considerations are important:

  • System Pressure/Temperature: Ensure the installed flange connection is rated for the operating pressure and temperature of the system.
  • Vibrazzjoni: In high-vibration environments, periodic checks for bolt loosening may be necessary. Consider using locking washers or thread-locking compounds if specified by the application.
  • Fatturi Ambjentali: Protect the connection from corrosive environments if the bolt material is not inherently resistant.

5. Manutenzjoni

Regular inspection and maintenance are crucial for the long-term reliability of the flange connection.

  • Spezzjoni Viżwali: Periodically inspect the bolts, nuts, and flange for signs of corrosion, cracks, deformation, or loosening.
  • Retorquing: After initial operation or significant temperature cycles, it may be necessary to retorque the bolts to the specified values. Consult equipment manufacturer guidelines.
  • Tindif: Keep the area around the flange connection clean to prevent accumulation of corrosive substances.
  • Sostituzzjoni: If any component (bolt, nut, washer) shows signs of significant wear, damage, or corrosion, replace the entire kit or individual components with identical specifications. Do not reuse damaged fasteners.

6 Issolvi l-problemi

Common issues related to bolt flange connections and potential solutions:

  • Tnixxija:
    • Kawża: Insufficient torque, improper gasket installation, damaged gasket, damaged flange face, uneven bolt tightening.
    • Soluzzjoni: Retorque bolts following the correct sequence and torque values. Inspect and replace gasket if necessary. Check flange faces for damage.
  • Boltijiet Sfużi:
    • Kawża: Vibration, thermal cycling, improper initial torque.
    • Soluzzjoni: Retorque bolts. Consider using locking mechanisms (e.g., lock washers, thread-locking compound) if appropriate for the application.
  • Korrużjoni:
    • Kawża: Exposure to harsh environments, incompatible materials.
    • Soluzzjoni: Clean and protect the connection. Replace corroded components. Consider using more corrosion-resistant materials or coatings for future applications if environmental conditions are severe.

7. Speċifikazzjonijiet

The Parker 201579 Bolt Flange Kit is manufactured to specific standards. Key details include:

  • Numru tal-Mudell: 201579
  • Ditta: Parker
  • Manifattur: PARKER
  • ASIN: B017TEABYY
  • Data L-Ewwel Disponibbli: 23 ta’ Jannar, 2018

For detailed dimensions, material composition, and performance ratings, refer to the official Parker product data sheets or contact Parker technical support.

8. Informazzjoni dwar Garanzija

Parker products are typically covered by a standard manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary. Please retain your proof of purchase. For detailed warranty information, including coverage, limitations, and how to make a claim, please refer to the official Parker warranty statement available on their corporate website or contact Parker customer service directly.

9. Appoġġ u Kuntatt

For technical assistance, product inquiries, or support regarding the Parker 201579 Bolt Flange Kit, please contact Parker customer service or your authorized Parker distributor. When contacting support, please have the model number (201579) and any relevant purchase information readily available.

You can typically find contact information on the official Parker websit: www.parker.com

Dokumenti Relatati - 201579

Preview Parker Mobile Hydraulics: Innovative Products and System Solutions
Discover Parker Hannifin's comprehensive catalog of mobile hydraulic components and system solutions, featuring pumps, motors, valves, cylinders, filtration, and more for enhanced mobile equipment performance and efficiency.
Preview Parker RAH121 Pilot Operated Relief Valve - Technical Specifications
Comprehensive technical details for the Parker RAH121 Pilot Operated Relief Valve, including its features, specifications, performance curve, dimensions, and ordering information. This spool-type hydraulic valve is designed for high accuracy and durability.
Preview Manwal tal-Utent tal-Parker NitroFlow Lab: Gwida għall-Ġeneratur tan-Nitroġenu
Manwal komprensiv għall-utent għall-ġeneratur tan-nitroġenu Parker NitroFlow Lab. Tgħallem dwar l-installazzjoni, it-tħaddim, il-manutenzjoni, is-sigurtà, u s-soluzzjoni tal-problemi għal din is-sistema avvanzata ta' ġenerazzjoni tal-gass.
Preview Parker Parflange® 170 ECO & WCM: Magni tal-Ivflaring tat-Tubi għal Konnessjonijiet F37
Dettaljat fuqview tal-magni tal-workshop Parker Parflange® 170 ECO u WCM għal flaring ta' tubi orbitali ta' 37°, iddisinjati għal konnessjonijiet tal-flanġ F37. Karatteristiċi, speċifikazzjonijiet, għażla tal-għodda, u benefiċċji għal applikazzjonijiet industrijali.
Preview Manwal ta' Referenza tas-Softwer tas-Sewqan b'Veloċità Varjabbli tas-Serje Parker AC20
Manwal komprensiv ta' referenza tas-softwer għall-Parker AC20 Series Variable Speed ​​Drive, li jiddeskrivi l-konfigurazzjoni, it-tħaddim, il-programmazzjoni u s-soluzzjoni tal-problemi tiegħu għal applikazzjonijiet industrijali.
Preview Manwal tal-Prodott tas-Sewqan tal-Frekwenza Varjabbli Parker AC10 Series IP66
Dan il-manwal tal-prodott jipprovdi informazzjoni dettaljata dwar l-installazzjoni, it-tħaddim, il-manutenzjoni, u l-ispeċifikazzjonijiet tekniċi għall-Parker AC10 Series IP66 Variable Frequency Drive (VFD) minn 0 sa 90kW.