Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of your myTouchSmart 25055 In-Wall Digital Countdown Timer. This device is designed to automate indoor and outdoor lighting, fans, or other devices, offering convenience and energy savings. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.
Informazzjoni Importanti dwar is-Sigurtà
- TWISSIJA: Risk of Electric Shock. Installation requires working with 120V AC wiring. Always turn off power at the circuit breaker or fuse box before installation.
- Dan l-apparat huwa maħsub għall-użu fuq ġewwa biss.
- A neutral wire is MEĦTIEĠA for proper installation and operation. If you are unsure, consult a qualified electrician.
- Do not exceed the electrical ratings: 120VAC 60 Hz, 15A General/Resistive, 1200W Tungsten, 1200VA Ballast, ½ HP.
- Kun żgur li l-konnessjonijiet kollha tal-wajers huma sikuri u iżolati sew.
- Aqra l-istruzzjonijiet kollha kompletament qabel tibda l-installazzjoni.
Kontenut tal-Pakkett
- myTouchSmart 25055 In-Wall Digital Countdown Timer
- Interchangeable White and Light Almond Switch Covers
- Manwal għall-Utent (dan id-dokument)
Note: A wall plate is not included and must be purchased separately.
Istruzzjonijiet għall-installazzjoni
- Itfi l-Enerġija: Locate the circuit breaker or fuse that supplies power to the switch you are replacing. Turn it OFF. Verify power is off by attempting to turn on the light or device controlled by the switch.
- Neħħi Swiċċ Eżistenti: Neħħi bir-reqqa l-pjanċa tal-ħajt u ħoll is-swiċċ eżistenti mill-kaxxa tal-ħajt. Skonnettja l-wajers mis-swiċċ il-qadim.
- Identifika l-Wajers: Identify the LINE (hot), LOAD, NEUTRAL, and GROUND wires. A neutral wire is MEĦTIEĠA for this timer. If you do not have a neutral wire, consult a qualified electrician.
- Qabbad it-Tajmer bil-wajer: Connect the wires to the myTouchSmart 25055 timer using the screw terminals as shown in the diagram below. Ensure all connections are tight and secure.
- LINE Wire: Connect to the terminal labeled "Line".
- Wajer tat-TAGĦBIJA: Connect to the terminal labeled "Load".
- Wajer NEWTRALI: Connect to the terminal labeled "Neutral".
- Wajer tal-ART: Connect to the terminal labeled "Ground".
- Immonta t-Tajmer: Gently push the wired timer into the wall box. Secure it with the provided screws.
- Installa Pjanċa tal-Ħajt: Attach your existing or a new wall plate (not included) over the timer.
- Irrestawra l-Enerġija: Erġa’ ixgħel il-provvista tal-enerġija mis-circuit breaker jew mill-kaxxa tal-fjużijiet.

Figure 1: Wiring Diagram. This image illustrates the correct connection points for the Line, Load, Neutral, and Ground wires on the back of the myTouchSmart 25055 timer module.
The timer includes interchangeable white and light almond switch covers to match your decor. To change the switch cover, carefully pry off the existing cover and snap on the desired color.
Operazzjoni
Issettjar tal-Ħin Kurrenti
- Agħfas il- ARLOĠĠ buttuna biex tidħol fil-mod tal-issettjar tal-ħin.
- Uża l- UP (▲) u 'L isfel (▼) arrow buttons to adjust the hour and minute. The time will scroll.
- Agħfas il- ARLOĠĠ Agħfas il-buttuna mill-ġdid biex tikkonferma u toħroġ mill-modalità tal-issettjar tal-ħin.
L-Użu ta' Programmi Presetjati
The myTouchSmart 25055 timer features three preset buttons for common scheduling needs:
- EVENING (5pm-12am): Activates the connected device from 5:00 PM to 12:00 AM.
- MORNING (5am-8am): Activates the connected device from 5:00 AM to 8:00 AM.
- ALL NIGHT (6pm-6am): Activates the connected device from 6:00 PM to 6:00 AM.
To activate a preset program, simply press the corresponding button (e.g., FILGĦAXIJA, FILGĦODU, IL-LEJL KOLLU). The blue LED indicator next to the button will illuminate to show it is active.
Custom Countdown Function
Il- Countdown button allows you to set a custom countdown timer for up to 24 hours.
- Agħfas il- Countdown button. The display will show "00:00".
- Uża l- UP (▲) u 'L isfel (▼) arrow buttons to set the desired countdown duration (up to 24 hours).
- Agħfas il- Countdown button again to start the countdown. The connected device will turn ON for the set duration and then turn OFF.
Override manwali mixgħul/mitfi
You can manually turn the connected device ON or OFF at any time, overriding any active program.
- Agħfas il- ON button to manually turn the device ON.
- Agħfas il- OFF button to manually turn the device OFF.

Figure 2: Simple Setup and Operation. This image highlights the scroll buttons for setting the current time and the preset buttons for activating schedules.
Karatteristiċi
- Wirja Diġitali: Clear digital display for time and countdown settings.
- Programmi Preset: Three convenient preset programs (Evening, Morning, All Night) and a Custom Countdown.
- Override manwali: Dedicated ON/OFF buttons for instant manual control.
- Indikaturi LED: Blue LED lights indicate active programs.
- Kompatibbiltà Wiesgħa: Works with LED, CFL, Incandescent, and Halogen bulbs, including dimmable LED and CFL.
- Batterija tal-Backup: Iżomm is-settings waqt li tkun qed tintefa' l-enerġijatages.
- Installazzjoni faċli: Screw terminal installation for efficient wiring.
- Għażliet Estetiċi: Includes interchangeable white and light almond switch covers.

Figure 3: Product Applications. This image demonstrates that the timer can control various devices such as indoor/outdoor lights, ceiling fans, and exhaust fans.
Manutenzjoni
- Clean the timer's surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or harsh chemicals.
- The internal backup battery is designed for long-term use and typically does not require replacement.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| It-tajmer ma jixgħelx. | No power to the switch box; incorrect wiring; neutral wire not connected. | Check circuit breaker. Verify wiring connections (Line, Load, Neutral, Ground). Ensure neutral wire is connected. |
| Connected device does not turn ON/OFF as scheduled. | Incorrect current time setting; program not activated; device malfunction. | Verify current time is set correctly. Ensure the desired program (Evening, Morning, All Night, Countdown) is active (blue LED). Test the connected device manually. |
| Id-displej huwa vojt jew jitteptep. | Low power; internal issue. | Ensure stable power supply. If problem persists, turn off power at the breaker for 5 minutes, then restore. If still unresolved, contact customer support. |
| Il-buttuni ma jirrispondux. | Problema temporanja tas-softwer; ħsara fiżika. | Turn off power at the breaker for 5 minutes, then restore. If still unresponsive, contact customer support. |
Speċifikazzjonijiet
- Mudell: 25055
- Klassifikazzjoni Elettrika: 120VAC, 60 Hz
- Tagħbija Massima: 15A General/Resistive, 1200W Tungsten, 1200VA Ballast, ½ HP
- Dimensjonijiet tal-Prodott: 2"D x 4.5"W x 6"H
- Timer Module Dimensions: Approximately 1.75" (4.45cm) width x 4.25" (10.8cm) height
- Materjal: Plastik
- Kulur: White (with interchangeable Light Almond option)
- Ċertifikazzjonijiet: Elenkat UL
- Wajer newtrali: Meħtieġa
- Batterija tal-Backup: NiMH (internal)

Figure 4: Timer Module Dimensions. This image provides the physical measurements of the timer module for installation reference.
Garanzija u Appoġġ
Għal informazzjoni dwar il-garanzija jew appoġġ tekniku, jekk jogħġbok irreferi għall-indirizz uffiċjali tal-manifattur. webis-sit jew ikkuntattja lid-dipartiment tas-servizz tal-konsumatur tagħhom. Żomm l-irċevuta tax-xiri tiegħek għal talbiet ta’ garanzija.