L-AQWA GREENER TSOS5-W

Manwal tal-Utent tas-Swiċċ tad-Dawl tas-Sensor tal-Mozzjoni PIR TOPGREENER TSOS5-W fil-Ħajt

Model: TSOS5-W

1. Introduzzjoni

The TOPGREENER TSOS5-W is an in-wall Passive Infrared (PIR) motion sensor light switch designed to automatically control lighting, fans, and motors based on occupancy detection. This single-pole switch requires a neutral wire for proper operation and offers AUTO, ON, and OFF modes for flexible control. It is suitable for various indoor applications, providing convenience and energy savings.

2. Informazzjoni Importanti dwar is-Sigurtà

TWISSIJA: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse and test that the power is off before wiring. Installation should be performed by a qualified electrician or a person with electrical knowledge.

3. Kontenut tal-Pakkett

Note: Wall plate sold separately.

4. Speċifikazzjonijiet tal-Prodott

Numru tal-MudellTSOS5-W
Voltage120VAC
Tip ta 'TagħbijaCFL/LED: 150W; Incandescent/Halogen: 500W; Motor: 1/8 HP; Fluorescent 500VA
Tip tas-SensorPIR (Passiv Infrared)
Qasam ta View180 grad
Żona ta' KoperturaSa 980 pied kwadru
Ħin DewmienAdjustable: 15 sec (test mode), 10 min, 20 min, 30 min
SensittivitàAdjustable: 30% to 100%
Rekwiżit tal-WajersWajer Newtrali Meħtieġa
Dimensjonijiet5.1 x 3 x 2.2 pulzieri
Piż4.97 uqija (0.14 Kilogrammi)
Tip ta 'ImmuntarEmbedded (In-Wall)

5. Istruzzjonijiet ta 'installazzjoni

Qabel ma tibda: Ensure power is OFF at the circuit breaker. This device requires a neutral wire. If you are unsure about your wiring, consult a qualified electrician.

5.1 Dijagramma tal-Wiring

The TSOS5-W switch has four wires for connection: Line (Hot), Load, Neutral, and Ground.

Quddiem view of the TOPGREENER TSOS5-W motion sensor switch

Figura 1: Quddiem view of the TOPGREENER TSOS5-W motion sensor switch, showing the sensor lens and the OFF-AUTO-ON slider.

Diagram showing the internal components of the motion sensor switch, highlighting the PIR sensor, customizable controls, daylight detection, fault tolerance, and fire-resistant materials.

Figure 2: Internal components of the TSOS5-W, illustrating the PIR sensor, customizable controls, and safety features.

5.2 Installazzjoni Pass Pass

  1. Itfi l-Enerġija: Locate the circuit breaker that controls the power to the switch box and turn it OFF. Verify power is off using a voltagtester.
  2. Neħħi s-Swiċċ il-Qadim: Carefully remove the existing wall plate and switch from the electrical box. Disconnect the wires from the old switch.
  3. Identifika l-Wajers: Identify the Line (Hot), Load, Neutral, and Ground wires in your electrical box. The neutral wire is typically white. If you are unsure, consult a qualified electrician.
  4. Qabbad Wajers: Using the provided wire nuts, connect the wires from the TSOS5-W switch to the corresponding wires in the electrical box:
    • Black switch wire to Line (Hot) wire.
    • Red switch wire to Load wire.
    • White switch wire to Neutral wire.
    • Green switch wire to Ground wire.
  5. Swiċċ tal-Immuntar: Carefully fold the wires into the electrical box and secure the TSOS5-W switch to the box using the mounting screws.
  6. Installa Pjanċa tal-Ħajt: Attach the wall plate (sold separately) over the switch.
  7. Irrestawra l-Enerġija: Erġa' ixgħel il-kurrent mis-circuit breaker.

6. Operazzjoni

The TSOS5-W features a slider switch for mode selection and adjustable dials for sensitivity and time delay, located behind the faceplate.

6.1 Għażla tal-Modalità

Close-up of the TSOS5-W switch showing the OFF, AUTO, and ON positions of the slider switch.

Figure 3: The OFF-AUTO-ON slider switch for mode selection.

6.2 Adjusting Settings (Behind Faceplate)

To access the adjustment dials, carefully remove the faceplate of the switch. You will find dials for Time Delay and Sensitivity.

Image showing the TSOS5-W switch installed in a laundry room, with a woman carrying a laundry basket. The text 'Hands-Free Occupancy modes auto ON/OFF' is overlaid.

Figure 4: The TSOS5-W in an occupancy sensing application, providing hands-free lighting control.

7 Issolvi l-problemi

ProblemaKawża / Soluzzjoni Possibbli
Lights do not turn ON/OFF or device does not work after installation.
  • Verify power is ON at the circuit breaker.
  • Ensure all wiring connections (Line, Load, Neutral, Ground) are correct and secure. A neutral wire is required.
  • Check if the switch is in the correct mode (AUTO, ON, OFF).
  • Confirm the load (light/fan) is functioning correctly.
  • Jekk il-kwistjoni tippersisti, ikkuntattja l-appoġġ tal-klijent.
Lights turn ON unexpectedly or stay ON too long.
  • Adjust the sensitivity dial to a lower setting.
  • Check for heat sources or air currents (e.g., HVAC vents, windows) within the sensor's field of view that might be causing false triggers.
  • Reduce the time delay setting.
Lights do not turn ON when motion is detected.
  • Ensure the switch is in AUTO mode.
  • Increase the sensitivity setting.
  • Verify the sensor's field of view ma jkunx ostakolat.
  • Check if the ambient light level is too high (some sensors have a daylight detection feature that prevents lights from turning on if sufficient natural light is present).
Cannot set time delay less than 10 minutes.
  • The specified time delay options are 15 seconds (test mode), 10 minutes, 20 minutes, and 30 minutes. Intermediate settings between 15 seconds and 10 minutes are not available.

8. Manutenzjoni

9. Garanzija u Appoġġ

TOPGREENER products are designed for reliability and performance. For warranty information or technical support, please contact TOPGREENER customer service. Refer to the product packaging or the official TOPGREENER websit għad-dettalji tal-kuntatt.

Manifattur: Top Greener Inc

Dokumenti Relatati - TSOS5-W

Preview Istruzzjonijiet għall-Installazzjoni tas-Swiċċ tas-Sensor tal-Okkupazzjoni TopGreener TSOS5/TWOS5
Istruzzjonijiet dettaljati għall-installazzjoni għas-swiċċijiet tas-sensor tal-okkupazzjoni TopGreener TSOS5 u TWOS5, inklużi speċifikazzjonijiet, dijagrammi tal-wajers, tħaddim, issolvi l-problemi, u informazzjoni dwar il-garanzija.
Preview Istruzzjonijiet għall-Installazzjoni tad-Dimmer LED Top Greener TGSDS3
Gwida komprensiva għall-installazzjoni għat-Top Greener TGSDS3 LED Dimmer, li tiddeskrivi l-wajers b'pol wieħed u bi 3 direzzjonijiet, l-ispeċifikazzjonijiet tal-prodott, l-istruzzjonijiet tat-tħaddim, u informazzjoni dwar il-garanzija.
Preview Gwida għall-Installazzjoni tas-Swiċċ tas-Sensor tal-Okkupazzjoni/Vakanza Topgreener TDOS5/TDOS5-NL
Gwida komprensiva għall-installazzjoni għas-Swiċċ tas-Sensor tal-Okkupazzjoni/Vakanza 2-f'1 Topgreener TDOS5/TDOS5-NL. Tinkludi speċifikazzjonijiet, dijagrammi tal-wajers, settings ta' aġġustament, modi ta' tħaddim, pariri dwar is-soluzzjoni tal-problemi, u informazzjoni dwar il-garanzija.
Preview Gwida għall-Installazzjoni tas-Sensor tal-Mozzjoni PIR tal-Umdità b'Teknoloġija Doppja TOPGREENER TDHOS5
Gwida komprensiva għall-installazzjoni u l-ipprogrammar għas-Sensor tal-Umdità u l-Mozzjoni PIR b'Teknoloġija Doppja TOPGREENER TDHOS5. Tkopri l-wajers, is-setup, il-karatteristiċi, is-soluzzjoni tal-problemi, u l-garanzija għal kontroll ottimali tad-dawl u l-fann tal-kamra tal-banju.
Preview Gwida għall-Installazzjoni tal-Kontroll tal-Fann tas-Sensor tal-Umdità TOPGREENER TDHS5
Istruzzjonijiet komprensivi għall-installazzjoni u gwida għall-utent għall-Kontroll tal-Fann bis-Sensor tal-Umdità TOPGREENER TDHS5. Tgħallem kif tqabbad, tipprogramma, u tħaddem il-kontroll tal-fann li jħoss l-umdità tiegħek għal ventilazzjoni ottimali tal-kamra tal-banju.
Preview Gwida għall-Installazzjoni u s-Setup tad-Dimmer Wi-Fi TOPGREENER TGWF500D
Gwida komprensiva għall-installazzjoni u s-setup għat-TOPGREENER TGWF500D Wireless Home Automation Wi-Fi Dimmer. Tgħallem kif tqabbad, tikkonnettja mal-Wi-Fi, u tħaddem id-dimmer intelliġenti tiegħek.