Zurn P1000AXL-150C

Zurn RV 150 PSI CA# FWL-2 Water Equipment User Manual

Model: P1000AXL-150C

1. Introduzzjoni u Fuqview

This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Zurn RV 150 PSI CA# FWL-2 Water Equipment. This device is designed to prevent over-pressure in storage tanks, ensuring system integrity and safety. Please read this manual thoroughly before installation or use.

Zurn RV 150 PSI CA# FWL-2 Water Equipment

Figura 1: Zurn RV 150 PSI CA# FWL-2 Water Equipment. This image shows the brass pressure relief valve with a male NPT inlet and a female NPT outlet, along with the pressure setting mechanism on top.

2. Informazzjoni dwar is-Sigurtà

TWISSIJA: Improper installation or use of this device can lead to property damage, serious injury, or death. All installation and maintenance should be performed by a qualified professional in accordance with local codes and regulations.

3. Karatteristiċi tal-prodott

4. X'hemm fil-Kaxxa

Il-pakkett tal-prodott tipikament jinkludi:

Please inspect the contents upon receipt to ensure all components are present and undamaged.

5. Setup u Installazzjoni

Installation should only be performed by a qualified plumber or technician. Adhere to all local plumbing codes and regulations.

  1. Depressurizzazzjoni tas-Sistema: Before beginning installation, ensure the water system is completely shut off and depressurized. Drain any residual water from the system.
  2. Għażla tal-Post: Install the relief valve in an accessible location on the storage tank or water equipment, typically at the highest point or as specified by the tank manufacturer.
  3. Thread Preparation: Apply appropriate thread sealant (e.g., PTFE tape or pipe dope) to the 3/4" male NPT inlet threads of the relief valve.
  4. Konnessjoni: Carefully thread the valve into the designated port on the storage tank. Tighten securely using a wrench, but do not overtighten, which can damage the valve or tank.
  5. Pajpijiet ta' Skariku: Connect appropriate discharge piping to the 3/4" female NPT outlet. The discharge pipe must be sized correctly, sloped for drainage, and terminate in a safe location where discharged water will not cause damage or injury. Do not cap or restrict the discharge pipe.
  6. System Repressurization: Slowly repressurize the system and check for leaks at all connections.
  7. Kontroll tal-Funzjonalità: Verify that the valve is not leaking and that the system pressure is within acceptable limits for the valve's setting.

6. Operazzjoni

The Zurn RV 150 PSI CA# FWL-2 Water Equipment is an automatic pressure relief valve. It is designed to open and discharge water when the system pressure exceeds its factory-set limit (e.g., 150 PSI for this model). This action prevents excessive pressure buildup within the storage tank, protecting the tank and connected components from potential damage.

Under normal operating conditions, the valve remains closed. If the valve discharges water, it indicates an over-pressure condition in the system. Investigate the cause of the over-pressure immediately.

7. Manutenzjoni

Regular inspection and maintenance are crucial for the continued safe operation of the relief valve. It is recommended to have the valve inspected annually by a qualified professional.

8 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Valve continuously drips or leaks.
  • Sediment or debris lodged in the valve seat.
  • Komponenti interni jintlibsu.
  • System pressure consistently too high.
  • Attempt manual test to flush debris.
  • Replace the valve if worn.
  • Check system pressure regulator or expansion tank.
Valve does not discharge during over-pressure.
  • Valve is seized or clogged.
  • Incorrect valve for application.
  • Attempt manual test. If still unresponsive, replace the valve immediately.
  • Verify valve specifications match system requirements.
Water discharges frequently.
  • System pressure fluctuations.
  • Expansion tank malfunction.
  • Valve set point too low for system.
  • Consult a professional to diagnose system pressure issues.
  • Inspect and service expansion tank.
  • Ensure correct valve is installed.

For persistent issues or if you are unsure about any troubleshooting steps, contact a qualified plumbing professional.

9. Speċifikazzjonijiet

AttributDettall
BrandZurn
Numru tal-MudellP1000AXL-150C
Deskrizzjoni tal-ProdottRV 150 PSI CA# FWL-2 Lead Free Water Equipment
Daqs3/4 pulzier
Konnessjoni tad-Dħul3/4" Male NPT
Konnessjoni tal-Ħut3/4" NPT femminili
MaterjalRam
KulurRam
Finish ta 'barraRam
Tip ta' ThreadNPT
Piż tal-oġġett0.5 Liri (madwar 8 uqija)
Dimensjonijiet tal-Prodott (L x W x H)1.25 x 1.25 x 3.44 pulzieri
ĊertifikazzjonijietCSA Compliance to ANSI Z21.22/CSA 4.4, Certified to ASME Section IV by National Board

10. Garanzija u Appoġġ

For information regarding product warranty, technical support, or replacement parts, please contact Zurn customer service directly. You can find contact information and additional resources on the official Zurn webis-sit jew billi żżur il- Zurn Store on Amazon.

Dokumenti Relatati - P1000AXL-150C

Preview Assemblaġġ tal-Valv li Jnaqqas il-Pressjoni Zurn Wilkins ZW209FP: Installazzjoni, Tħaddim, u Manutenzjoni
Gwida komprensiva għall-assemblaġġ tal-valv li jnaqqas il-pressjoni tal-protezzjoni min-nar Zurn Wilkins ZW209FP, li tkopri l-installazzjoni, il-bidu, it-tħaddim, il-karatteristiċi tal-fluss, u l-proċeduri ta' manutenzjoni. Tinkludi struzzjonijiet dettaljati għall-valv prinċipali u l-valv pilota PV-PRD.
Preview Valv tat-Tnaqqis tal-Pressjoni Zurn NR3XL mingħajr Ċomb: Gwida għall-Installazzjoni, Manutenzjoni u Tiswija
Gwida komprensiva għall-Valv tat-Tnaqqis tal-Pressjoni mingħajr Ċomb Zurn NR3XL, li tkopri l-installazzjoni, l-ispezzjoni, il-manutenzjoni, il-proċeduri ta' tiswija, u s-soluzzjoni tal-problemi. Tinkludi l-ispeċifikazzjonijiet tal-prodott u informazzjoni dwar il-garanzija.
Preview Zurn NR3XL Water Pressure Reducing Valve with Integral By-Pass Check Valve and Strainer
Detailed specifications and installation guide for the Zurn NR3XL, a water pressure reducing valve designed for potable water lines. Features include an integral strainer, by-pass check valve, and low lead cast bronze body. Suitable for residential and commercial applications.
Preview Zurn AquaSense ZER-SM Series Automatic Battery-Powered Flush Valve Manual
Comprehensive manual for Zurn AquaSense ZER-SM series automatic battery-powered flush valves, covering installation, operation, maintenance, troubleshooting, and parts breakdown for models like ZER6000-SM, ZER6200-SM, ZER6003-SM, and ZER6203-SM.
Preview ZURN Model AG Air Gap Adaptor Fitting
The ZURN Model AG Air Gap Adaptor Fitting is designed for use with ZURN WILKINS Reduced Pressure Principle Backflow Preventers, ensuring proper drain line installation on horizontal or vertical systems. This document details its specifications, materials, and typical installation requirements.
Preview Speċifikazzjonijiet u Installazzjoni tal-Assemblea tal-Interruttur tal-Vakwu tal-Pressjoni Zurn Wilkins Mudell 720A
Informazzjoni dettaljata dwar l-Assemblea tal-Interruttur tal-Vakwu tal-Pressjoni Zurn Wilkins Mudell 720A, inkluża l-applikazzjoni tagħha, il-konformità mal-istandards, il-materjali, il-karatteristiċi, id-dimensjonijiet, il-piżijiet, il-karatteristiċi tal-fluss, u l-linji gwida tal-installazzjoni kemm għall-użu fuq ġewwa kif ukoll fuq barra.