The Visionis FPC-5281 Kit is a comprehensive one-door standalone access control system designed for out-swinging doors. This kit provides secure access management for various environments, including rooms, offices, or buildings, by allowing entry through multiple methods: PIN code, proximity card, and keytag. It integrates essential components for a complete access solution, including a magnetic lock, an outdoor-rated keypad/reader, a mini controller, an exit button, a doorbell, and a PIR motion sensor for request-to-exit functionality.

X'hemm fil-Kaxxa

The FPC-5281 kit includes the following components:

  • (1) VIS-ML300LED: 300lbs indoor Electric magnetic lock with LED Sensor
  • (1) VIS-3000: Access Control Indoor + Outdoor Rated IP68 Metal Digital Touch Keypad + Reader Standalone with Mini Controller + Wiegand 26, Wide Design, No Software, EM Cards
  • (1) VIS-MINI-CNTRL: 1 Door Controller for Access Control Systems with No Software. Up to 1,000 users
  • (1) VIS-7005: Indoor Ultra Thin Push + Touch To Exit Button For Door Access Control with LED Light NC COM and NO Outputs
  • (1) VIS-8006: External hardwire Doorbell for Keypad/Reader Access Control
  • (1) Irexplus: Rokonet Risco IrexPlus Request to Exit PIR motion Sensor with Internal Buzzer and Relay Timer
  • (2) VISCP100: 12v 1000mA Power supply, UL listed
  • (10) VS-VIS-APROXCARD/26: Access Control Proximity contactless Smart Entry card 1.8mm thick 26 bit 125khz
  • (10) VS-VIS-KEYTAG: Access Control Proximity contactless Smart Entry Keyfob 26 bit 125khz
All components of the Visionis FPC-5281 Access Control Kit

Figure 1: Complete FPC-5281 Kit Components

Prodott Overview

VIS-3000 Keypad/Reader

The VIS-3000 is an indoor and outdoor rated IP68 metal digital touch keypad and proximity card reader. It supports up to 1,000 users and offers Wiegand 26 input/output. It allows for access via PIN code, proximity card, and keytag.

Video 1: VIS-3000 Product OverviewDan il-filmat jipprovdi ħarsa ġenerali lejnview of the VIS-3000 keypad, highlighting its features and applications.

Dimensions of the VIS-3000 Keypad

Figure 2: VIS-3000 Keypad Dimensions (81mm x 118mm x 21mm)

Access methods for VIS-3000 Keypad

Figure 3: VIS-3000 Keypad Access Methods (Card, PIN, Card + PIN, Phone NFC)

VIS-ML300LED Magnetic Lock

The VIS-ML300LED is a 300lbs indoor electric magnetic lock featuring an LED sensor for status indication.

Dimensions of the VIS-ML300LED Magnetic Lock

Figure 4: VIS-ML300LED Magnetic Lock Dimensions

VIS-MINI-CNTRL Mini Controller

The VIS-MINI-CNTRL is a 1-door controller designed for access control systems without software, supporting up to 1,000 users.

Dimensions of the VIS-MINI-CNTRL Mini Controller

Figure 5: VIS-MINI-CNTRL Mini Controller Dimensions

Internal board of the VIS-MINI-CNTRL Mini Controller

Figure 6: VIS-MINI-CNTRL Mini Controller Internal Board

VIS-7005 Exit Button

The VIS-7005 is an indoor ultra-thin push + touch to exit button for door access control, featuring an LED light and NC COM and NO outputs.

Dimensions of the VIS-7005 Exit Button

Figure 7: VIS-7005 Exit Button Dimensions

VIS-8006 External Hardwire Doorbell

The VIS-8006 is an external hardwire doorbell compatible with the keypad/reader access control system.

Dimensions of the VIS-8006 External Doorbell

Figure 8: VIS-8006 External Doorbell Dimensions

Irexplus PIR Motion Sensor

The Irexplus Rokonet Risco IrexPlus is a Request to Exit PIR motion sensor with an internal buzzer and relay timer.

Dimensions of the Irexplus PIR Motion Sensor

Figure 9: Irexplus PIR Motion Sensor Dimensions

Access Cards and Keyfobs

The kit includes ten VS-VIS-APROXCARD/26 proximity contactless smart entry cards (1.8mm thick, 26 bit, 125khz) and ten VS-VIS-KEYTAG proximity contactless smart entry keyfobs (26 bit, 125khz) for user access.

Speċifikazzjonijiet

KaratteristikaDettall
BrandViżjonijiet
MudellFPC-5281
Sors tal-EnerġijaCorded Elettriku
Apparati KompatibbliSmartphone (for NFC with VIS-3000, if applicable)
Teknoloġija tal-KonnettivitàBil-fili
Tip ta' InstallazzjoniSelf-Adhesive (for some components, professional installation recommended)
Tip ta 'TwissijaMotion (PIR sensor)
Piż tal-oġġett7.44 Liri
Komponenti InklużiKeypad, Magnetic Lock, Mini Controller, Exit Button, Doorbell, PIR Sensor, Power Supplies, Access Cards, Keyfobs
UPC701772944324
Dimensjonijiet tal-Pakkett13 x 10 x 5.1 pulzieri
Data L-Ewwel Disponibbli10 ta’ Lulju, 2015

Setup

Installation of the FPC-5281 access control system requires careful wiring and mounting of components. It is highly recommended that installation be performed by a qualified professional to ensure proper functionality and safety.

Passi Ġenerali ta' Installazzjoni:

  1. Ippjanar: Determine the optimal placement for the magnetic lock, keypad, exit button, PIR sensor, and controller. Consider cable routing and power access.
  2. Immuntar: Securely mount the magnetic lock to the door frame and door, ensuring proper alignment for the 300lbs holding force. Install the VIS-3000 keypad on the exterior side of the door and the VIS-7005 exit button on the interior side. Mount the VIS-MINI-CNTRL controller in a secure, protected location, typically near the door.
  3. Wiring: Connect all components to the VIS-MINI-CNTRL controller according to the provided wiring diagrams. Ensure all connections are secure and insulated. Pay close attention to power connections (12V DC) and data lines (Wiegand 26).
  4. Konnessjoni tal-Enerġija: Connect the UL listed 12V 1000mA power supplies to the system. Verify correct polarity.
  5. Konfigurazzjoni Inizjali: Power on the system. The VIS-3000 keypad will require initial programming to set up administrator codes and add user credentials (PINs, cards, keyfobs). Refer to the specific user manual for the VIS-3000 and VIS-MINI-CNTRL for detailed programming instructions.
  6. Ittestjar: Thoroughly test all access methods (PIN, card, keytag) and the exit functionality (exit button, PIR sensor) to ensure the system operates as expected. Verify the magnetic lock engages and disengages correctly.
Diagram showing the complete access control system setup

Figure 10: System Setup Diagram

Istruzzjonijiet Operattivi

Accessing the Door:

  • Using a PIN Code: Enter your assigned PIN code on the VIS-3000 keypad, followed by the '#' key. The magnetic lock will disengage, allowing the door to open.
  • Using a Proximity Card/Keytag: Present your registered proximity card or keytag to the VIS-3000 keypad. The magnetic lock will disengage upon successful recognition.
  • Using Card + PIN: If configured for Card + PIN mode, present your card/keytag, then enter your PIN code followed by '#'.
  • Exiting the Door: From the inside, press the VIS-7005 exit button or trigger the Irexplus PIR motion sensor. The magnetic lock will temporarily disengage, allowing you to exit.

Adding/Deleting Users (Administrator Function):

The VIS-3000 keypad and VIS-MINI-CNTRL controller allow for the management of user credentials. This typically involves entering a master code to access programming mode, then following prompts to add or delete user PINs, cards, or keyfobs. Refer to the detailed programming guide provided with the VIS-3000 and VIS-MINI-CNTRL for specific steps on user management.

Manutenzjoni

Regular maintenance helps ensure the longevity and reliable operation of your Visionis FPC-5281 access control system.

  • Tindif: Periodically clean the VIS-3000 keypad surface with a soft, damp drapp. Evita prodotti tat-tindif jew solventi li joborxu li jistgħu jagħmlu ħsara lill-finitura jew lill-elettronika.
  • Kontroll tal-Konnessjoni: Annually, or if issues arise, inspect all wiring connections for tightness and signs of wear or corrosion. Ensure power supply connections are secure.
  • Magnetic Lock Inspection: Check the magnetic lock and armature plate for any debris or misalignment that could affect its holding force. Keep the contact surfaces clean.
  • PIR Sensor Check: Ensure the PIR sensor's lens is clean and unobstructed. Test its functionality periodically to confirm it triggers correctly for exit requests.
  • Aġġornamenti tal-Firmware: While this system is standalone and typically does not require software, check the Visionis website for any potential firmware updates for the keypad or controller that might enhance performance or address known issues.

Issolvi l-problemi

If you encounter issues with your FPC-5281 access control system, refer to the following common problems and solutions:

ProblemaKawża PossibbliSoluzzjoni
Keypad is unresponsive or no power.No power to the keypad/controller; loose wiring.Check power supply connections. Ensure the power adapter is plugged in and functional. Verify all wiring to the controller and keypad is secure.
Door does not unlock with valid PIN/card.Incorrect PIN; unregistered card/keytag; magnetic lock issue; wiring problem.Double-check the PIN code. Ensure the card/keytag is properly registered in the system. Inspect wiring between the controller and magnetic lock. Check if the magnetic lock is receiving power.
Magnetic lock does not engage/lock.Power issue to the lock; faulty lock; door sensor issue.Verify the lock is receiving constant power when the door should be locked. Check for any obstructions between the lock and armature plate. Consult a professional if the lock appears faulty.
Exit button or PIR sensor does not unlock the door.Faulty button/sensor; wiring issue; incorrect controller setting.Check wiring connections for the exit button and PIR sensor to the controller. Ensure the PIR sensor's detection area is clear. Verify controller settings for exit trigger.
Doorbell (VIS-8006) is not working.Wiring issue; faulty doorbell unit.Check the wiring connections for the doorbell. Ensure it is correctly connected to the keypad/controller.

For more complex issues or if the problem persists, please contact Visionis technical support.

Garanzija u Appoġġ

For detailed information regarding product warranty, technical support, and service, please refer to the official Visionis webis-sit jew ikkuntattja lis-servizz tal-konsumatur tagħhom direttament. L-informazzjoni ta' kuntatt tipikament tista' tinstab fuq l-imballaġġ tal-prodott jew fuq l-uffiċjal tal-manifattur websit.

Visionis Store: https://www.amazon.com/stores/Visionis/page/CED6F248-BD2E-47A3-A7E0-ECF1E2C44BCE

Dokumenti Relatati - FPC-5281

Preview VISIONIS VIS-3004 & VIS-3005 Manwal għall-Utent tal-Kontroll tal-Aċċess Standalone
Dan il-manwal tal-utent jipprovdi gwida komprensiva għall-VISIONIS VIS-3004 u l-VIS-3005, sistemi avvanzati ta' kontroll tal-aċċess standalone iddisinjati għas-sigurtà ta' bieb wieħed. Dawn l-apparati jikkombinaw tastiera sigura ma' qarrej tal-kards tal-prossimità, u joffru soluzzjoni affidabbli għall-immaniġġjar tal-aċċess f'ambjenti diversi, minn bini kummerċjali sa komunitajiet residenzjali. Esplora informazzjoni dettaljata dwar il-karatteristiċi tal-prodott, l-ispeċifikazzjonijiet tekniċi, l-istruzzjonijiet ta' installazzjoni pass pass, il-konfigurazzjonijiet tal-wajers, u l-għażliet estensivi ta' programmazzjoni.
Preview VISIONIS VIS-3000/VIS-3003 Manwal tal-Utent tal-Kontroll tal-Aċċess Standalone
Manwal tal-utent għat-tastieri tal-kontroll tal-aċċess standalone VISIONIS VIS-3000 u VIS-3003 u l-qarrejja tal-kards tal-prossimità. Ikopri l-karatteristiċi, l-ispeċifikazzjonijiet, l-installazzjoni, il-wajers, l-ipprogrammar, l-operazzjonijiet tal-utent, u l-funzjonijiet tal-allarm.
Preview Manwal tal-Utent tal-Qarrej tal-Kards tal-Kontroll tal-Aċċess/Tastiera Visionis VIS-3008
Manwal tal-utent għall-qarrej tal-kards tal-kontroll tal-aċċess u tastiera standalone reżistenti għat-temp Visionis VIS-3008 IP68. Il-karatteristiċi jinkludu appoġġ għall-kards EM/MF, Wiegand 26-37 bit, kapaċità ta' 2000 utent, u settings avvanzati għall-kontroll tal-aċċess.
Preview Gwida għall-Utent tal-Kontroll tal-Aċċess Kummerċjali VISIONIS VIS-AXESS-2ETL
Gwida għall-utent għas-sistema ta' Kontroll tal-Aċċess Kummerċjali VISIONIS VIS-AXESS-2ETL. Tagħti dettalji dwar il-parametri tal-apparat, il-funzjonijiet bażiċi, id-dijagrammi tal-wajers, is-setup tas-softwer b'TITAN VSAxess, u avviżi importanti ta' installazzjoni għal ġestjoni sigura tal-aċċess.
Preview Manwal tal-Utent VISIONIS VIS-3004: Tastiera u Qarrej tal-Kontroll tal-Aċċess
Manwal komprensiv għall-utent għat-tastiera tal-kontroll tal-aċċess u l-qarrej tal-kards tal-prossimità VISIONIS VIS-3004. Ikopri l-installazzjoni, il-wajers, il-programmazzjoni, it-tħaddim mill-utent, il-funzjonijiet tal-allarm, u l-ispeċifikazzjonijiet.
Preview VISIONIS VIS-600D-LED Double Door Magnetic Lock Installation Guide
Installation and power requirement guide for the VISIONIS VIS-600D-LED Double Door Magnetic Lock with LED Status Sensor. Includes wiring schematics and mounting instructions.