1. Introduzzjoni

This manual provides essential information for the proper use, handling, and storage of the CORNING 352099 Polystyrene Falcon Graduated Tube. These tubes are designed for laboratory applications requiring accurate volume measurement and centrifugation of samples. They are manufactured to high-quality standards to ensure reliable performance in life science research.

2. Informazzjoni dwar is-Sigurtà

  • Always wear appropriate personal protective equipment (PPE), such as lab coats, gloves, and eye protection, when handling laboratory samples and equipment.
  • Handle tubes with care to prevent breakage or contamination.
  • Ensure caps are securely tightened to prevent leakage, especially during centrifugation.
  • Do not exceed the maximum recommended RCF (Relative Centrifugal Force) for these tubes.
  • Dispose of used tubes and samples according to laboratory and institutional waste disposal protocols.
  • These tubes are sterile and non-pyrogenic; maintain sterility during handling if required for sensitive applications.

3. Prodott Aktarview

The CORNING 352099 Falcon Graduated Tube is a high-quality laboratory consumable designed for various applications including sample storage, preparation, and centrifugation. Key features include:

  • Materjal: Optically clear polystyrene for easy sample viewing.
  • Kapaċità: 15 mL.
  • Dimensjonijiet: 17 mm Outer Diameter (OD) x 120 mm Length.
  • Gradwazzjonijiet: Easy-to-read dark blue printed graduations for accurate volume measurement.
  • Writing Patch: Large white writing area for clear sample identifikazzjoni.
  • Kap: Easy on/off screw cap with a double thread design to ensure a leak-proof seal.
  • Ċentrifugazzjoni: Rated for a maximum RCF of 1800 x g.
  • Sterilità: Supplied sterile, non-pyrogenic, and non-toxic.
  • Manifattura: Produced in ISO 9001:2000 and ISO 13485:2003 certified facilities.
Corning Falcon 15 mL Polystyrene Graduated Tube with blue screw cap

An image showing the clear polystyrene Falcon graduated tube with a blue screw cap. The tube features dark blue printed graduations and a white writing patch. The bottom is conical.

4. Setup

  1. Spakkjar: Carefully remove the tubes from their sterile packaging. Ensure the packaging is intact upon receipt.
  2. Spezzjoni: Visually inspect each tube for any signs of damage, cracks, or manufacturing defects before use. Do not use damaged tubes.
  3. Preparazzjoni: If sterility is critical, handle tubes in a sterile environment (e.g., laminar flow hood) using aseptic techniques.

5. Istruzzjonijiet Operattivi

  1. Mili: Żid tiegħek sample to the tube. Use the printed graduations to accurately measure the desired volume. Avoid overfilling beyond the maximum capacity to prevent spillage or leakage.
  2. Capping: Securely screw the cap onto the tube. Ensure the cap is finger-tight to create a leak-proof seal, especially if the tube will be inverted or centrifuged.
  3. Tikkettjar: Use the large white writing patch to clearly label the tube with sample information, date, and any other relevant details. Use laboratory-grade markers that will not smudge or fade.
  4. Ċentrifugazzjoni: If centrifuging, ensure the tube is properly balanced in the centrifuge rotor. Do not exceed the maximum RCF of 1800 x g. Refer to your centrifuge manual for specific operating instructions.
  5. Ħażna: Aħżen samples in the tubes according to your experimental requirements (e.g., refrigeration, freezing). Ensure caps remain securely closed during storage.

6. Manutenzjoni

These Falcon tubes are designed for single-use applications and are supplied sterile. They are not intended for cleaning and re-use, as this can compromise their sterility, structural integrity, and performance characteristics.

  • Ħażna: Store unused tubes in their original packaging in a clean, dry environment at room temperature, away from direct sunlight or extreme temperatures.
  • Rimi: Dispose of used tubes and their contents in accordance with local, state, and federal regulations for laboratory waste.

7 Issolvi l-problemi

  • Tnixxija: If leakage occurs, ensure the cap is securely tightened. Check for any damage to the tube or cap threads. Do not reuse leaking tubes.
  • Tube Breakage: Ensure the maximum RCF is not exceeded during centrifugation. Verify that the centrifuge rotor is balanced correctly. Polystyrene tubes are generally not recommended for very high-speed centrifugation or use with certain organic solvents that may compromise their integrity.
  • Kontaminazzjoni: If contamination is suspected, verify that aseptic techniques were followed during handling and that the sterile packaging was intact prior to use.

8. Speċifikazzjonijiet

AttributValur
Isem tal-ProdottCORNING 352099 Polystyrene Falcon Graduated Tube
Numru tal-Mudell352099
MaterjalPolistirene
Kapaċità15 mL
Dijametru ta' Barra (OD)17 mm
Tul120 mm
RCF massimu1800 xg
Ippakkjar50/Rack
SterilitàSterile, Non-pyrogenic, Non-toxic
ManifatturCORNING INCORPORATED
Dimensjonijiet tal-Prodott22 x 11 x 12 pulzieri (ippakkjar); 10.8 Liri (piż)

9. Garanzija

Corning products are manufactured to high-quality standards. For specific warranty information regarding the CORNING 352099 Polystyrene Falcon Graduated Tube, please refer to the official Corning website or contact Corning customer service directly. General warranties typically cover manufacturing defects under normal use conditions.

10. Appoġġ

For technical assistance, product inquiries, or to report any issues, please contact Corning customer support:

  • Websit: Visit the official Corning Life Sciences websit għal informazzjoni dwar il-prodott u riżorsi ta' appoġġ.
  • Informazzjoni ta' Kuntatt: Refer to the Corning website for regional contact details, including phone numbers and email addresses.

Dokumenti Relatati - 352099

Preview Corning Permeable Supports Selection Guide: Transwell and Falcon Cell Culture Inserts
A comprehensive guide from Corning and Fisher Scientific to select the optimal permeable supports, including Transwell and Falcon cell culture inserts, based on membrane type, pore size, format, and surface treatment for various research applications.
Preview Manwal tal-Utent tas-Sistema Corning Everon 6000 MIMO: Konfigurazzjonijiet, LEDs, u Speċifikazzjonijiet RF
Manwal dettaljat għall-utent għas-sistemi MIMO tas-serje Everon 6000 ta' Corning Optical Communications. Ikopri konfigurazzjonijiet 2x2, 2TO1, u 4TO1 b'komponenti dLRU, DEU, DCU, RIU, BTS, dMRU, u dHRU. Jinkludi definizzjonijiet tal-istatus tal-LED, verżjonijiet tar-rilaxx, u twissijiet ta' espożizzjoni kritika għall-RF għal installazzjoni professjonali.
Preview Manwal tal-Utent Corning MRU & HRU: Gwida għall-Installazzjoni u t-Tħaddim
Dan il-manwal tal-utent jipprovdi struzzjonijiet komprensivi għall-installazzjoni, il-konfigurazzjoni, u t-tħaddim tas-sistemi MRU (Digital Medium-power Remote Unit) u HRU (High Power Remote Unit) ta' Corning, komponenti essenzjali għall-infrastruttura tan-netwerk mingħajr fili.
Preview Manwal tal-Istruzzjonijiet tal-Corning Matribot Bioprinter
Manwal ta' struzzjonijiet komprensiv għall-Corning Matribot Bioprinter, li jiddeskrivi s-setup, it-tħaddim, il-manutenzjoni, u s-soluzzjoni tal-problemi għal applikazzjonijiet avvanzati ta' bijostampar fl-inġinerija tat-tessuti u l-kultura taċ-ċelloli 3D.
Preview Istruzzjonijiet ta' Installazzjoni ta' Corning KS500/KS250 RJ45 Keystone Cat.6A/6
Gwida komprensiva għall-installazzjoni għall-Corning KS500 u KS250 RJ45 Keystone Jacks (Cat.6A/6, protetti/mhux protetti). Tkopri informazzjoni dwar it-tħejjija, il-wajers, l-assemblaġġ, u l-ordnijiet.
Preview Gwida ta' Referenza tal-Kejbils Corning u Arista 40G, 100G, 400G, u 800G
A comprehensive guide from Corning Optical Communications detailing cabling scenarios, transceiver types, and part numbers for Arista networks supporting 40G, 100G, 400G, and 800G data rates. Includes local and across-data-center connections.