Red Lion 97081001

Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump Instruction Manual

Mudell: 97081001

1. Introduzzjoni

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-SWJ100 1 HP Cast Iron Shallow Well Jet Pump. Please read these instructions thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump, red cast iron body with black motor housing.
Figure 1: Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump

2. Informazzjoni dwar is-Sigurtà

WARNING: Risk of severe injury or death by electrical shock, or damage to the system.

A person wearing blue work clothes and gloves is handling electrical wires, emphasizing the need for electrical experience.
Figure 2: Electrical experience is required for installation.

3. Prodott Aktarview

The Red Lion RL-SWJ100 is a 1 HP cast iron shallow well jet pump designed for providing fresh water to rural homes, farms, and cottages. It is suitable for suction lifts down to 25 feet. The pump includes a 30/50 pressure switch and is self-priming after initial prime.

Karatteristiċi ewlenin:

Diagram showing the internal components and features of the Red Lion RL-SWJ series shallow well jet pump, including motor terminal box, adjustable pressure switch, 1 inch FNPT discharge, 1-1/4 inch FNPT intake, cast iron casing, glass-filled thermoplastic impeller and diffuser, and integrated venturi/nozzle assembly.
Figure 3: RL-SWJ Series Features Diagram

4. Speċifikazzjonijiet

AttributValur
Numru tal-Mudell97081001
Horsepower (HP)1 HP
Voltage115/230 Volts (Dual Voltage)
Ampetà13.2 Amps @ 115V; 6.6 Amps @ 230V
Wattage4800 watt
Rata massima tal-fluss17 Galluni Kull Minuta (GPM)
Pressjoni massima74 PSI
Suction/Intake1-1/4-inch Female NPT
KwittanzaNPT femminili ta' pulzier wieħed
MaterjalCast Iron (body), Glass-filled thermoplastic (impeller/volute)
Dimensjonijiet tal-Prodott (L x W x H)14"T x 9"W x 9.5"Għ
Piż tal-oġġett28.5 Liri
Komponenti Inklużi30/50 Pressure Switch, Instruction Manual, Pump
Performance chart for Red Lion RL-SWJ100 shallow well jet pump, showing total dynamic head versus capacity in US GPM at 5 feet of lift for 1/2 HP, 3/4 HP, and 1 HP models.
Figure 4: RL-SWJ100 Performance Chart
Dimensional drawing of the Red Lion RL-SWJ100 shallow well jet pump with height, length, width, and weight specifications.
Figure 5: RL-SWJ100 Dimensions

5. Setup u Installazzjoni

5.1 Titjiratage Għażla

The RL-SWJ100 pump is dual voltage (115/230 Volts) and comes factory-set for 230 Volts. Ensure the pump's voltage setting matches your power source. To change the voltage, remove the cover from the motor terminal box and slide the voltage indicator switch to the desired setting (115V or 230V) using a flat screwdriver.

Diagram illustrating the voltage switch on the Red Lion RL-SWJ series pump, showing positions for 230V and 115V settings.
Figura 6: Voltage Switch Settings

Video 1: This video demonstrates how to change the voltage setting on a Red Lion RL-SWJ Series Jet Pump from 230V to 115V or vice versa.

5.2 Pressure Tank Installation

If installing with a pressure tank, ensure the tank's pre-charge pressure is set correctly before installation. The pre-charge pressure should be 2 PSI below the pump's cut-in pressure setting (e.g., 28 PSI for a 30 PSI cut-in). Make all pipe connections according to local plumbing codes. Ensure the pipe size from the tank to the house is the same as the pipe size from the pump to the tank.

Video 2: This video provides instructions on how to install or adjust a pressure tank in conjunction with a jet pump system.

6. Istruzzjonijiet Operattivi

6.1 Priming tal-Pompa

Before starting the pump for the first time or after it has been drained, it must be properly primed. This involves filling the pump casing and suction line with water to ensure it can create the necessary suction to draw water from the well. Refer to the detailed priming instructions in the full owner's manual for your specific setup.

6.2 Start-up Inizjali

After priming and ensuring all connections are secure and leak-free, restore power to the pump. The pump should start and build pressure. Monitor the pressure gauge to ensure it reaches the desired cut-off pressure (e.g., 50 PSI for a 30/50 switch). The pump will automatically shut off once the cut-off pressure is reached.

7. Manutenzjoni

8 Issolvi l-problemi

This section provides general guidance for common issues. For detailed troubleshooting steps, consult the complete owner's manual.

Kwistjonijiet Komuni:

9. Garanzija u Appoġġ

9.1 Informazzjoni dwar Garanzija

The Red Lion RL-SWJ100 pump comes with a 2-year manufacturer's warranty. For specific terms and conditions, please refer to the warranty details provided with your product or contact Red Lion customer support.

9.2 Appoġġ għall-Klijent

For troubleshooting assistance, installation guidance, or to inquire about parts and service, please contact Red Lion customer support. If your product was purchased within 30 days, refer to Amazon's return policy. For purchases beyond 30 days, consult your owner's manual or contact the seller directly if different from Amazon.com.

For additional information, visit the official Red Lion websit: www.redlionproducts.com

Dokumenti Relatati - 97081001

Preview Red Lion Pump Troubleshooting Guide: Solutions for Jet, Submersible, and Transfer Pumps
Comprehensive troubleshooting guide for Red Lion water pumps, including Shallow Well Jet Pumps (e.g., RJS-50-PREM), Convertible Jet Pumps (e.g., RJC-50), 4" Submersible Well Pumps (e.g., RL12G10-3W2V), Submersible Utility & Sump Pumps, RL-S Cast Iron Surface Effluent Pumps, RL-50 Transfer Pumps, and RLSP/RLHE Sprinkler Pumps. Find solutions for common issues like motor failure, priming problems, low pressure, and more.
Preview Red Lion PWJET50 Shallow Well Jet Pump Owner's Manual and Installation Guide
This document provides comprehensive owner's manual and installation guidance for the Red Lion PWJET50 Shallow Well Jet Pump. It details safety instructions, installation procedures, operation, maintenance, and troubleshooting for efficient water supply in rural applications.
Preview Gwida għas-Soluzzjoni tas-Soluzzjoni tal-Pompa Red Lion
Gwida komprensiva għas-soluzzjoni ta' problemi għall-pompi Red Lion, li tkopri kwistjonijiet komuni b'pompi bil-ġett ta' bjar baxxi, pompi bil-ġett konvertibbli, pompi sommerġibbli, pompi tal-utilità, u pompi tat-trasferiment imħaddma mill-magna. Tinkludi soluzzjonijiet għal mutur li ma jixgħelx, pompa li ma twassalx l-ilma, telf ta' priming, kapaċità mnaqqsa, u ċikliżmu frekwenti.
Preview Red Lion RJSE-75SS Sprinkler Utility Pump - Operation and Maintenance Manual
Comprehensive guide for the Red Lion RJSE-75SS Sprinkler Utility Pump, covering safety warnings, electrical precautions, application, installation, operation, maintenance, and troubleshooting. Includes detailed diagrams and warranty information.
Preview Red Lion RL-SPRK Series Sprinkler Pump Owner's Manual - Installation, Operation, Maintenance Guide
This manual provides comprehensive instructions for the Red Lion RL-SPRK Series Sprinkler Pumps, covering installation, voltage settings, operation, maintenance, troubleshooting, and replacement parts. Designed for residential and commercial lawn and turf sprinkler systems.
Preview Red Lion RLHE-300 Cast Iron Industrial Sprinkler Pump Owner's Manual
Comprehensive owner's manual for the Red Lion RLHE-300 industrial sprinkler pump, covering installation, operation, maintenance, and troubleshooting. Features include heavy-duty iron casing, high-efficiency impeller, and automatic thermal protector.