1. Introduzzjoni
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-SWJ100 1 HP Cast Iron Shallow Well Jet Pump. Please read these instructions thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

2. Informazzjoni dwar is-Sigurtà
WARNING: Risk of severe injury or death by electrical shock, or damage to the system.
- Dejjem skonnettja l-enerġija elettrika qabel tmiss il-pompa.
- A Ground Fault Circuit Interrupter (GFCI) is required for electrical connections.
- Jekk il-korda tal-enerġija tkun bil-ħsara, għandha tiġi sostitwita biss minn persunal kwalifikat.
- Installation and servicing of this equipment should be performed by technically qualified personnel familiar with the correct selection and use of appropriate tools, equipment, and procedures.
- Dan il-prodott jista’ jesponik għal kimiċi inkluż iċ-ċomb, li huwa magħruf mill-Istat ta’ California li jikkawża l-kanċer u difetti fit-twelid jew ħsara riproduttiva oħra. Għal aktar informazzjoni żur www.P65Warnings.ca.gov.

3. Prodott Aktarview
The Red Lion RL-SWJ100 is a 1 HP cast iron shallow well jet pump designed for providing fresh water to rural homes, farms, and cottages. It is suitable for suction lifts down to 25 feet. The pump includes a 30/50 pressure switch and is self-priming after initial prime.
Karatteristiċi ewlenin:
- Shallow Well Application: Designed for wells less than 25 feet deep.
- Doppju Voltage Motor: Heavy-duty 115/230 Volt motor, factory-set for 230 Volts, easily switchable to 115 Volts.
- Kostruzzjoni Durabbli: Heavy-duty cast iron casing for longevity. Impeller and volute are made of glass-filled thermoplastic.
- Integrated Pressure Switch: Includes a 30/50 pressure switch with auto shut-off.
- Konnessjonijiet: 1-1/4-inch Female NPT threaded intake; 1-inch Female NPT threaded discharge.

4. Speċifikazzjonijiet
| Attribut | Valur |
|---|---|
| Numru tal-Mudell | 97081001 |
| Horsepower (HP) | 1 HP |
| Voltage | 115/230 Volts (Dual Voltage) |
| Ampetà | 13.2 Amps @ 115V; 6.6 Amps @ 230V |
| Wattage | 4800 watt |
| Rata massima tal-fluss | 17 Galluni Kull Minuta (GPM) |
| Pressjoni massima | 74 PSI |
| Suction/Intake | 1-1/4-inch Female NPT |
| Kwittanza | NPT femminili ta' pulzier wieħed |
| Materjal | Cast Iron (body), Glass-filled thermoplastic (impeller/volute) |
| Dimensjonijiet tal-Prodott (L x W x H) | 14"T x 9"W x 9.5"Għ |
| Piż tal-oġġett | 28.5 Liri |
| Komponenti Inklużi | 30/50 Pressure Switch, Instruction Manual, Pump |


5. Setup u Installazzjoni
5.1 Titjiratage Għażla
The RL-SWJ100 pump is dual voltage (115/230 Volts) and comes factory-set for 230 Volts. Ensure the pump's voltage setting matches your power source. To change the voltage, remove the cover from the motor terminal box and slide the voltage indicator switch to the desired setting (115V or 230V) using a flat screwdriver.

Video 1: This video demonstrates how to change the voltage setting on a Red Lion RL-SWJ Series Jet Pump from 230V to 115V or vice versa.
5.2 Pressure Tank Installation
If installing with a pressure tank, ensure the tank's pre-charge pressure is set correctly before installation. The pre-charge pressure should be 2 PSI below the pump's cut-in pressure setting (e.g., 28 PSI for a 30 PSI cut-in). Make all pipe connections according to local plumbing codes. Ensure the pipe size from the tank to the house is the same as the pipe size from the pump to the tank.
Video 2: This video provides instructions on how to install or adjust a pressure tank in conjunction with a jet pump system.
6. Istruzzjonijiet Operattivi
6.1 Priming tal-Pompa
Before starting the pump for the first time or after it has been drained, it must be properly primed. This involves filling the pump casing and suction line with water to ensure it can create the necessary suction to draw water from the well. Refer to the detailed priming instructions in the full owner's manual for your specific setup.
6.2 Start-up Inizjali
After priming and ensuring all connections are secure and leak-free, restore power to the pump. The pump should start and build pressure. Monitor the pressure gauge to ensure it reaches the desired cut-off pressure (e.g., 50 PSI for a 30/50 switch). The pump will automatically shut off once the cut-off pressure is reached.
7. Manutenzjoni
- Spezzjoni regolari: Periodically check all connections for leaks and ensure the pump is securely mounted.
- Pressure Tank Check: Verify the pressure tank's air charge annually.
- Winterization: In freezing climates, drain the pump and piping completely to prevent damage from ice expansion.
- Indafa: Keep the pump area clean and free from debris to ensure proper ventilation.
8 Issolvi l-problemi
This section provides general guidance for common issues. For detailed troubleshooting steps, consult the complete owner's manual.
Kwistjonijiet Komuni:
- Pump runs but no water: Check for proper priming, ensure the suction line is submerged, and inspect for air leaks in the suction line.
- Il-pompa tiċċirkola spiss wisq: This often indicates a problem with the pressure tank (low air charge, waterlogged) or a leak in the system.
- Il-pompa ma tibdax: Verify electrical connections, check the circuit breaker, and ensure the voltagIs-swiċċ huwa ssettjat sew.
- Pressjoni baxxa: Check for clogs in the piping, inspect the impeller for damage, and verify the well's water level.
9. Garanzija u Appoġġ
9.1 Informazzjoni dwar Garanzija
The Red Lion RL-SWJ100 pump comes with a 2-year manufacturer's warranty. For specific terms and conditions, please refer to the warranty details provided with your product or contact Red Lion customer support.
9.2 Appoġġ għall-Klijent
For troubleshooting assistance, installation guidance, or to inquire about parts and service, please contact Red Lion customer support. If your product was purchased within 30 days, refer to Amazon's return policy. For purchases beyond 30 days, consult your owner's manual or contact the seller directly if different from Amazon.com.