1. Introduzzjoni
This manual provides comprehensive instructions for the installation, operation, and maintenance of the UHPPOTE 125KHz RFID Access Control Kit. This system is designed to provide secure access management for outswinging doors, utilizing an RFID keypad, electromagnetic lock, and associated components. Please read this manual thoroughly before installation and operation to ensure correct usage and optimal performance.
2. Informazzjoni dwar is-Sigurtà
- Sigurtà Elettrika: Installation should be performed by qualified personnel. Ensure power is disconnected before any wiring work.
- Voltage: The system operates on 12VDC. Using incorrect voltage may damage components.
- Ambjent: Do not expose components to water, high humidity, or extreme temperatures unless specified as waterproof.
- Magnetic Lock: The electromagnetic lock generates a strong magnetic field. Keep sensitive electronic devices and magnetic media away from the lock.
3. Kontenut tal-Pakkett
The UHPPOTE 125KHz RFID Access Control Kit typically includes the following components:
- 1x Access Control Keypad
- 1x 600lbs Electric Magnetic Lock (280kg holding force)

Immaġni 3.1: Fuqview of the UHPPOTE 125KHz RFID Access Control Kit components, including the keypad, magnetic lock, power supply, remote control, exit button, and RFID cards/fobs.
- 1x Power Supply Unit (12VDC, 3A)
- 1x Remote Control Receiver
- 2x Remote Control Transmitters
- 1x Exit Button
- RFID Cards and Key Fobs (quantity may vary)
- Mounting Hardware and Connectors
4. Prodott Aktarview
4.1 Access Control Keypad
The keypad serves as the primary interface for access control, supporting RFID card, PIN, or a combination of both. It features a numeric keypad, bell button, and status indicator light.

Stampa 4.1.1: Quddiem view of the access control keypad, showing the numeric buttons and RFID card reader area.

Immaġni 4.1.2: Wara view of the access control keypad, revealing the internal circuit board and wiring terminals for connection.
4.2 Electric Magnetic Lock
The 600lbs (280kg) holding force electromagnetic lock provides secure door locking. It operates in NC (Normally Closed) mode, meaning it is locked when power is supplied and unlocks upon power interruption (fail-safe).

Image 4.2.1: The electromagnetic lock unit and its corresponding armature plate, which attaches to the door.

Immaġni 4.2.2: Interna view of the magnetic lock, showing the wiring terminals for power connection.
4.3 Power Supply Unit
The power supply unit converts AC input to 12VDC output, providing stable power to all components. It includes terminals for various connections, including lock output, battery backup (optional), and control signals.

Stampa 4.3.1: Quddiem view of the power supply unit, displaying input and output specifications and safety warnings.

Image 4.3.2: Close-up of the power supply unit's output terminals, labeled for various connections like CTRL+, BAT+, GND, PUSH, NO, COM, NC.
5. Speċifikazzjonijiet
5.1 Access Control Keypad (Model: HBK-A01)
- Vol Operattivtage: 12VDC
- Lock Output Tagħbija: Max. 1.5A
- Kurrent inattiv: 50mA
- RFID Card Capacity: 500 utent
- Kapaċità tal-PIN: 500 utent
- PIN Digits: 4-8 ċifri
- Tip ta' Karta: Standard 125KHz EM compatible card (Does not support encrypted cards like HID, Indala, etc.)
- Door Relay Time: 0-99 sekonda (aġġustabbli)
- Materjal tal-qoxra: Plastic ABS
- Piż tal-Prodott: 3.5oz (100g)
- Distanza tal-Qari tal-Kards: Max. 2-23/64" (6cm)
- Dimensjonijiet tal-qoxra: 3-15/16"x3-15/16"x47/64" (100x100x18.5mm)
- Door Open Options: Card Only / Password Only / Card + Password / Card or Password
- Temperatura tax-Xogħol: -22 ° F ~ 140 ° F (-30 ° C ~ 60 ° C)
- Umdità tax-Xogħol: 10% -90% RH, mingħajr kondensazzjoni
- Konnessjonijiet tal-Wiring: Serratura Elettrika, Buttuna tal-Ħruġ, Qanpiena Esterna
5.2 Electromagnetic Lock (Model: 600lbs)
- Input Voltage: 12VDC, 520mA
- Forza ta' Żamma: 600lbs (280kg)
- Modalità: NC (Normally Closed) - locked while supplied with power, fail-safe
- Kuntatt tal-Output: LE/NC/COM
5.3 Power Supply Unit (Model: HBK-P01)
- Input: 100-240VAC 50/60Hz
- Output: 12VDC/3A
6. Setup u Installazzjoni
Proper installation is crucial for the reliable operation of your access control system. Refer to the detailed wiring diagram below and the specific instructions for each component.
6.1 Dijagramma tal-Wiring
The following diagram illustrates the typical wiring connections between the power supply, access control keypad, magnetic lock, exit button, and other optional accessories.

Image 6.1.1: Comprehensive wiring diagram showing connections for the power supply, access control keypad, electric lock, exit button, and optional battery/intercom.
Noti Importanti:
- Kun żgur li l-konnessjonijiet kollha huma siguri u iżolati biex jipprevjenu short circuits.
- The power supply unit has terminals for CTRL+ u CTRL- which connect to the keypad's lock output.
- The magnetic lock connects to the LE (Normally Open) and COM (Common) terminals of the power supply for fail-safe operation (locked when powered).
- The exit button connects to the IMBOTTA u GND terminali tal-provvista tal-enerġija.
- For detailed component-specific wiring, refer to the individual instruction sheets provided with each part.
6.2 Magnetic Lock Installation
The magnetic lock is typically installed on the door frame, and the armature plate on the door itself. For outswinging doors, Z-brackets or L-brackets may be required (sold separately) to ensure proper alignment and secure mounting.
- Determine the optimal mounting position for the magnetic lock on the door frame and the armature plate on the door, ensuring they align perfectly when the door is closed.
- Mount the magnetic lock body to the door frame using appropriate screws and brackets.
- Attach the armature plate to the door. Ensure it has a slight pivot to allow full contact with the electromagnet.
- Run wiring from the magnetic lock to the power supply unit, following the wiring diagram.
6.3 Keypad Installation
- Choose a suitable indoor location near the door for the keypad, at a comfortable height for users.
- Mount the keypad securely to the wall using the provided screws.
- Connect the keypad's wiring to the power supply unit and the magnetic lock as per the wiring diagram.
6.4 Installazzjoni tal-Unità tal-Provvista tal-Enerġija
- Mount the power supply unit in a secure, dry location, preferably near the main power source and other system components.
- Connect the AC input (100-240VAC) to a suitable power outlet.
- Connect all other components (keypad, magnetic lock, exit button, remote receiver) to the appropriate terminals on the power supply unit.
7. Istruzzjonijiet Operattivi
This section details how to program and use your access control system.
7.1 Initial Power-Up and Master Code Setup
- After all wiring is complete and checked, connect the power supply to the AC source.
- The keypad will power on. The default master code is typically 1234 or 9999. Refer to the keypad's specific manual for the exact default.
- Change the Master Code Immediately: Enter the default master code, then follow the keypad's programming instructions to set a new, secure master code. This code is essential for managing user access.
7.2 Programming User PINs and RFID Cards
The keypad allows for adding and deleting user PINs and RFID cards/fobs.

Image 7.2.1: A user presenting an RFID card to the access control keypad for authentication.
- Daħħal il-Mod ta 'Programmar: Typically, this involves entering the Master Code followed by a specific key (e.g., # or *).
- Add User PIN: Select the option to add a user, then enter a unique 4-8 digit PIN for the new user.
- Żid Karta RFID: Select the option to add a card, then present the RFID card or fob to the keypad's reader area. The keypad will register it.
- Ħruġ mill-Modalità tal-Ipprogrammar: Press the appropriate key (e.g., * or #) to save changes and exit programming mode.
Nota: It is recommended to assign a unique user ID or number to each card/fob for easier management and deletion if needed.
7.3 Accessing the Door
- L-użu ta' PIN: Enter your registered 4-8 digit PIN on the keypad.
- Using an RFID Card/Fob: Present your registered RFID card or fob to the keypad's reader area.
- Using the Exit Button: Press the physical exit button located inside the door to momentarily unlock the magnetic lock.
- L-użu tal-Kontroll mill-bogħod: Press the designated button on the remote control transmitter to unlock the door. The remote receiver must be properly wired to the power supply.
7.4 Adjusting Door Relay Time
The door relay time (how long the lock remains unlocked after a valid entry) can be adjusted on the keypad, typically from 0 to 99 seconds. Refer to your keypad's specific manual for instructions on how to enter this setting in programming mode.
8. Manutenzjoni
- Tindif: Clean the keypad and magnetic lock surfaces with a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Kontrolli regolari: Periodically check all wiring connections for tightness and signs of wear.
- Magnetic Lock Alignment: Ensure the magnetic lock and armature plate remain properly aligned for optimal holding force. Misalignment can reduce security.
- Provvista tal-Enerġija: Verify the power supply unit is free from dust and has adequate ventilation.
- Battery Backup (if installed): Test the battery backup system regularly to ensure it functions during power outages.
9 Issolvi l-problemi
If you encounter issues with your access control system, refer to the following common problems and solutions:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Magnetic lock does not hold or is weak. |
|
|
| It-tastiera ma tirrispondix jew ma tixgħelx. |
|
|
| RFID card/fob not recognized. |
|
|
| Door does not unlock with valid PIN/card. |
|
|
| Il-kontroll mill-bogħod ma jaħdimx. |
|
|
10. Garanzija u Appoġġ
For warranty information, please refer to the documentation provided at the time of purchase or contact UHPPOTE customer service directly. UHPPOTE products typically come with a limited warranty covering manufacturing defects.