Introduzzjoni
The Sunwa YX-360TRD is a versatile analog multimeter designed for a wide range of electrical measurements. This instrument allows for precise measurement of AC/DC voltage, DC current, resistance, capacitance, and diode functionality. Its analog display provides a clear, real-time indication of readings, making it suitable for various applications from hobbyist electronics to professional diagnostics.
This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your Sunwa YX-360TRD Analog Multimeter. Please read this manual thoroughly before using the device to ensure proper functionality and safety.
Informazzjoni dwar is-Sigurtà
Always observe the following safety precautions to prevent personal injury and damage to the multimeter or equipment under test:
- Aqra l-istruzzjonijiet kollha: Before using the multimeter, carefully read and understand all operating instructions and safety warnings.
- Voltage Limiti: Do not exceed the maximum input limits for any measurement range. Refer to the specifications section for detailed limits.
- Insulazzjoni: Ensure your hands are dry and that you are standing on an insulated surface when making measurements.
- Test Leads: Use only the test leads supplied with the multimeter. Inspect test leads for damage before each use. Do not use if insulation is damaged or if metal is exposed.
- Fjusis: The multimeter is all range fused. If a fuse blows, replace it only with a fuse of the specified type and rating.
- Circuit De-energization: Always de-energize the circuit and discharge all high-voltage capacitors before making resistance, capacitance, or diode measurements.
- Kundizzjonijiet Ambjentali: Do not use the multimeter in wet or explosive atmospheres.
- Servizzi: Refer all servicing to qualified service personnel. Do not attempt to repair the multimeter yourself.
Prodott Overview
The Sunwa YX-360TRD Analog Multimeter features a clear analog display and intuitive controls for various measurement functions.

Figura 1: Quddiem View of Multimeter. This image shows the front of the Sunwa YX360-TRD analog multimeter, highlighting its large analog scale, function selector dial, and integrated test leads. The scale displays ranges for DCV, ACV, DCA, Resistance, and Capacitance. The selector dial is prominently positioned for easy function and range selection.

Figure 2: Multimeter with Back Stand. This image displays the Sunwa YX360-TRD multimeter from an angled perspective, showing its integrated back stand extended. The stand allows the multimeter to be propped up for easier viewing of the analog display during operation.
Komponenti Ewlenin:
- Display Analog: Large, easy-to-read scale for various measurements. Features a mirrored scale for accurate readings by reducing parallax error.
- Dial tas-Selettur tal-Funzjoni/Firxa: Used to select the desired measurement function (DCV, ACV, DCA, Resistance, Capacitance) and the appropriate range.
- Test Leads: Permanently attached red (positive) and black (negative) test leads for connecting to the circuit under test.
- Ω-ADJ Knob: Used to zero the ohmmeter before making resistance measurements.
- Back Stand: Integrated stand for convenient upright positioning.
- Test Leads Compartment: Built-in storage for test leads when not in use.
Setup
Installazzjoni tal-batterija:
The Sunwa YX-360TRD requires two AA batteries for operation. These are typically pre-installed. If replacement is needed:
- Sib il-kompartiment tal-batterija fuq wara tal-multimeter.
- Iftaħ b'attenzjoni l-għatu tal-batterija.
- Daħħal żewġ batteriji AA, waqt li tiżgura l-polarità korretta (+ u -).
- Agħlaq l-għatu tal-batterija sew.

Figura 3: Wara View u l-Kompartiment tal-Batterija. This image shows the back of the Sunwa YX360-TRD multimeter, illustrating the robust plastic case and the location of the battery compartment. The design emphasizes durability and ease of access for battery replacement.
Spezzjoni Inizjali:
Before first use, inspect the multimeter for any signs of physical damage. Ensure the test leads are securely attached and free from cuts or abrasions.
Istruzzjonijiet Operattivi
Before taking any measurement, ensure the multimeter is set to the correct function and range. Always start with a higher range if the approximate value is unknown to prevent damage to the meter.
1. Kejl tal-Volum DCtage (DCV):
- Set the function/range selector dial to the desired DCV range (e.g., 0.25V, 2.5V, 10V, 50V, 250V, 1000V).
- Qabbad il-wajer tat-test aħmar man-naħa pożittiva (+) taċ-ċirkwit u l-wajer tat-test iswed man-naħa negattiva (-).
- Aqra l-voltage value on the DCV scale of the analog display.
Note: The DCV ranges include 0 - 0.1V ±1% and 0.25V/2.5/10V/50V/250/1000V ±3%.
2. Kejl AC Voltage (ACV):
- Set the function/range selector dial to the desired ACV range (e.g., 10V, 50V, 250V, 1000V).
- Qabbad il-wajers tat-test mal-vultaġġ ACtagsors e.
- Aqra l-voltage value on the ACV scale of the analog display.
Note: The ACV ranges are 0 - 10/50/250/1000V ±4%.
3. Measuring DC Current (DCA):
- TWISSIJA: Qatt ma tqabbad il-multimetru b'mod parallel ma' voltagSors elettroniku meta tkejjel il-kurrent. Dejjem qabbad f'serje mat-tagħbija.
- Set the function/range selector dial to the desired DCA range (e.g., 50µA, 2.5mA, 25mA, 250mA).
- Break the circuit and connect the multimeter in series with the load. The red lead connects to the higher potential side, and the black lead to the lower potential side.
- Read the current value on the DCA scale.
Note: The DCA ranges are 0 - 50µA/2.5mA/25mA/250mA ±3%. This meter can measure currents as low as 10 micro amps.
4. Measuring Resistance (Ω):
- TWISSIJA: Kun żgur li ċ-ċirkwit ma jkollux l-enerġija u li l-kapaċitaturi kollha jkunu skarikati qabel ma tkejjel ir-reżistenza.
- Set the function/range selector dial to the desired Resistance range (e.g., x1, x10, x100, x1K, x10K, x100K).
- Short the test leads together (touch red to black).
- Adjust the Ω-ADJ knob until the needle points to '0' on the Ohms scale. This zeros the ohmmeter.
- Connect the test leads across the component whose resistance you wish to measure.
- Read the value on the Ohms scale and multiply by the selected range multiplier.
Note: The Resistance ranges are 0 - 2K/20K/2MKohm ±3% and 200M ±5%.
5. Capacitance Estimation (C):
- TWISSIJA: Ensure the capacitor is fully discharged before connecting the multimeter.
- Set the function/range selector dial to the 'C' (Capacitance) range.
- Qabbad il-wajers tat-test mal-kapaċitatur.
- Observe the needle's deflection. The scale provides an estimation of capacitance.
Note: The Capacitance range is 0 - 10 µF.
6. Diode Check:
- Set the function/range selector dial to the Diode check position.
- Connect the red test lead to the anode and the black test lead to the cathode of the diode. The meter should show a low resistance reading (forward bias).
- Reverse the test leads. The meter should show a very high or infinite resistance reading (reverse bias).
- This function can also be used to check LEDs.
Manutenzjoni
Tindif:
Imsaħ il-każ bl-adamp drapp u deterġent ħafif. Tużax sustanzi abrażivi jew solventi. Żomm id-displej nadif għal qari ottimali.
Sostituzzjoni tal-batterija:
Replace batteries when the meter's readings become erratic or the needle does not zero correctly in resistance mode. Refer to the "Setup" section for battery installation instructions.
Ħażna:
Meta ma tkunx qed tużah għal perjodi twal, neħħi l-batteriji biex tevita t-tnixxija. Aħżen il-multimeter f'post frisk u niexef, 'il bogħod mix-xemx diretta u minn temperaturi estremi.
Sostituzzjoni tal-fjus:
The Sunwa YX-360TRD features all-range fusing for protection. If the meter stops functioning on a particular range, a fuse may have blown. Fuse replacement should only be performed by qualified personnel using the correct fuse type and rating as specified in the product's internal documentation or by the manufacturer.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Meter does not power on / No needle movement. | Batteriji mejta jew installati ħażin. | Iċċekkja l-polarità tal-batterija u ibdel il-batteriji jekk meħtieġ. |
| Incorrect or erratic readings. | Low battery, incorrect range selection, damaged test leads, or blown fuse. | Replace batteries, select appropriate range, inspect and replace test leads if damaged, check and replace fuses if blown. |
| Cannot zero ohmmeter (Ω-ADJ). | Batterija baxxa jew problema interna. | Replace batteries. If problem persists, seek professional service. |
| No reading on a specific function. | Blown fuse for that specific range/function. | Have a qualified technician check and replace the fuse. |
Speċifikazzjonijiet
- DC Voltage (DCV):
- 0 - 0.1V ±1%
- 0.25V / 2.5V / 10V / 50V / 250V / 1000V ±3%
- AC Voltage (ACV):
- 0 - 10V / 50V / 250V / 1000V ±4%
- DC Current (DCA):
- 0 - 50µA / 2.5mA / 25mA / 250mA ±3%
- Reżistenza (Ω):
- 0 - 2KΩ / 20KΩ / 2MΩ ±3%
- 200MΩ ±5%
- Capacitance (C): 0 - 10 µF
- dB: -10 dB - 22 dB
- Diode Check: Yes (including LED)
- DC Sensitivity: 20kΩ/V
- Sors tal-Enerġija: 2 x AA Batteries (installed)
- Karatteristiċi: All range fused, Back stand, Plastic case with cover, Test leads compartment, Compact size, Mirrored scale.
- Dimensjonijiet tal-Prodott: 6.75 x 1 x 4.75 pulzieri
- Piż tal-oġġett: 7.05 uqija (200 Grammi)
- Numru tal-Mudell: YX360-TRD
Garanzija u Appoġġ
Informazzjoni dwar il-garanzija:
The Sunwa YX360-TRD Analog Multimeter comes with a 1 Snin Garanzija from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, abuse, accident, unauthorized alteration or repair, or natural causes.
Appoġġ għall-Klijent:
For technical assistance, warranty claims, or general inquiries, please contact Mastech customer support. Refer to the contact information provided with your purchase documentation or visit the official Mastech webis-sit għad-dettalji ta' appoġġ l-aktar aġġornati.
Riżorsi onlajn: Għal aktar informazzjoni u riżorsi, tista' żżur il- Ħanut Mastech fuq Amazon.