Buderus 7098822

Buderus Airclon GB 112-24 7098822 Floating Insert Instruction Manual

Introduzzjoni

This instruction manual provides essential information for the safe and effective installation, operation, and maintenance of the Buderus Airclon GB 112-24 7098822 Floating Insert. Please read this manual thoroughly before proceeding with any procedures to ensure proper function and longevity of the product. Retain this manual for future reference.

Prodott Overview

The Buderus Airclon GB 112-24 7098822 Floating Insert is a critical component designed for use in condensing boilers, specifically compatible with Buderus GB 112, GB 142, Winner BK 11, WT 24, and Nefit systems. Its primary function is to facilitate the automatic venting of air from the heating system, which is crucial for efficient operation and to prevent corrosion and noise.

Image of the Buderus Airclon Floating Insert and an air vent cap
Figura 1: The image displays two components. On the left is the white, conical floating insert with a thin metal rod extending from its base and a hooked metal wire attached to its top. On the right is a hexagonal metal cap with a beige, circular top and a black, knurled valve cap. These components are typically used together in an air vent system.

Istruzzjonijiet għall-installazzjoni

Prekawzjonijiet tas-Sigurtà:

Proċedura:

  1. Locate the Air Vent: Identify the automatic air vent on your compatible Buderus, Winner, or Nefit condensing boiler.
  2. Remove Old Insert (if applicable): Carefully unscrew the existing air vent cap or housing. The old floating insert may be removed at this stage.
  3. Spezzjona u Naddaf: Inspect the air vent housing for any debris or scale buildup. Clean thoroughly if necessary to ensure proper sealing and function.
  4. Insert New Float: Gently place the new Buderus Airclon GB 112-24 7098822 Floating Insert into the air vent housing. Ensure it sits correctly and is not obstructed. The metal rod should point downwards.
  5. Erġa' arma: Screw the air vent cap or housing back into place. Tighten securely but do not overtighten.
  6. Repressurize System: Slowly refill and repressurize the heating system according to the boiler manufacturer's instructions.
  7. Iċċekkja għal Tnixxijiet: Monitor the air vent for any signs of water leakage after repressurizing.
  8. Irrestawra l-Enerġija: Once installation is complete and no leaks are detected, restore power to the boiler.

Istruzzjonijiet Operattivi

The Buderus Airclon GB 112-24 7098822 Floating Insert operates automatically. Its design allows air to escape from the heating system while preventing water loss. When air accumulates in the vent, the float drops, opening a valve to release the air. As water fills the vent, the float rises, closing the valve to prevent water from escaping. No manual intervention is typically required for its basic operation.

Ensure the small black cap on the air vent (if present, as shown in Figure 1) is slightly loosened or open to allow air to escape. Do not remove it completely unless specified by the boiler manufacturer.

Manutenzjoni

Regular maintenance ensures the optimal performance and longevity of your floating insert and heating system.

Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Air not venting from system (gurgling noises, cold radiators)Float insert blocked by debris or scale; vent cap closed; faulty insert.Ensure vent cap is slightly open. Clean air vent housing. Replace floating insert if necessary.
Water leaking from air ventFloat insert worn or damaged; improper seating; vent cap loose.Tighten vent cap (do not overtighten). Check seating of insert. Replace floating insert.

If troubleshooting steps do not resolve the issue, contact a qualified heating technician for assistance.

Speċifikazzjonijiet

AttributDettall
ManifatturBuderus
Numru tal-Parti7098822
Numru tal-Mudell tal-Oġġett7098822
Dimensjonijiet tal-Prodott10 x 1.5 x 10 ċm
Piż58 g
Kompatibbli ma 'Buderus GB 112, GB 142; Winner BK 11, WT 24; Nefit

Garanzija u Appoġġ

Specific warranty information for the Buderus Airclon GB 112-24 7098822 Floating Insert may vary depending on your region and point of purchase. Please refer to your purchase documentation or contact your supplier for details regarding warranty coverage.

For technical support or further assistance, please contact Buderus customer service or your authorized Buderus dealer. When contacting support, please have your product model number (7098822) and purchase details readily available.

Dokumenti Relatati - 7098822

Preview Manwal tal-Installazzjoni u l-Manutenzjoni tal-Buderus 500-24C/500-28C
Istruzzjonijiet komprensivi għall-installazzjoni u l-manutenzjoni għall-bojlers kombinati tal-gass li jikkondensaw Buderus 500-24C u 500-28C li jitwaħħlu mal-ħajt. Jinkludi speċifikazzjonijiet tekniċi, linji gwida dwar is-sigurtà, u proċeduri operattivi għall-installaturi.
Preview Passaport Tekniku tal-Bojler tal-Kondensazzjoni tal-Gass Buderus Logamax plus GB272
Passaport tekniku għall-bojler tal-kondensazzjoni tal-gass Buderus Logamax plus GB272, li jagħti dettalji dwar l-ispeċifikazzjonijiet, il-komponenti, id-dejta operattiva, u l-informazzjoni dwar il-manifattur.
Preview Manwal tal-Applikazzjonijiet tal-Buderus Logamax plus GB162: Konfigurazzjonijiet u Kontrolli tas-Sistema
Esplora l-manwal tal-applikazzjonijiet tal-bojler tal-kondensazzjoni tal-gass Buderus Logamax plus GB162. Din il-gwida tagħti dettalji dwar il-konfigurazzjonijiet tas-sistema, l-għażliet ta' kontroll bħal AM10 u RC35, is-sistemi kaskata, u l-ispeċifikazzjonijiet tekniċi għal soluzzjonijiet ottimali ta' tisħin.
Preview Manwal tal-Applikazzjonijiet tal-Bojler tal-Kondensazzjoni tal-Gass Buderus Logamax plus GB162
Manwal komprensiv tal-applikazzjonijiet għall-bojler tal-kondensazzjoni tal-gass Buderus Logamax plus GB162, li jagħti dettalji dwar il-komponenti tas-sistema, l-istrateġiji ta' kontroll, il-konfigurazzjonijiet tal-kaskata, u sampapplikazzjonijiet għal soluzzjonijiet effiċjenti ta' tisħin u DHW.
Preview Buderus Logamax plus GB272: Planungsunterlage für Gas-Brennwertgeräte
Umfassende Planungsunterlage für Buderus Logamax plus GB272 Gas-Brennwertgeräte. Enthält technische Daten, Installationsbeispiele und Betriebsweise für effiziente Heizsysteme.
Preview Buderus Logano GE315 Installation and Maintenance Instructions
Comprehensive guide for the installation and maintenance of the Buderus Logano GE315 cast iron sectional boiler for oil or gas pressure jet burners. Covers regulations, installation steps, system start-up, maintenance procedures, and troubleshooting.