Introduzzjoni
The Mastech MS8235 is a versatile 2-in-1 instrument combining a full-featured auto-ranging digital multimeter with a comprehensive LAN cable tester. This device is engineered for precision and safety, making it an essential tool for electricians, network technicians, and DIY enthusiasts. It provides accurate measurements for various electrical parameters and efficiently diagnoses common network cable issues.
Informazzjoni dwar is-Sigurtà
Always adhere to safety precautions when operating the Mastech MS8235. Failure to do so may result in electric shock, injury, or damage to the meter or equipment under test.
- CAT III 600V Rating: This meter is designed for measurements in distribution boards, circuit breakers, wiring, including cables, bus-bars, junction boxes, switches, socket outlets in the fixed installation, and industrial use with permanent connection to the fixed installation. Do not exceed the specified voltage u limiti kurrenti.
- Before each use, inspect the test leads for any damage. Do not use if insulation is cracked or if the leads are exposed.
- Kun żgur li s-swiċċ rotatorju jkun fil-pożizzjoni korretta għall-kejl mixtieq qabel ma tqabbad il-wajers tat-test maċ-ċirkwit.
- Tippruvax tkejjel il-voltage or current on circuits exceeding the meter's maximum input ratings.
- Exercise extreme caution when working with live circuits. Always use appropriate personal protective equipment (PPE).
- Never operate the meter with the battery cover removed.
- If the 'Low Battery' indicator appears, replace the batteries immediately to ensure accurate readings.
Prodott Overview

Quddiem view of the Mastech MS8235 Digital Multimeter with LAN Tester, showing the LCD display, function buttons, rotary switch, and input jacks.
Komponenti u Kontrolli:
- Display LCD: Large digital display (2000 counts) showing measurement values, units (kΩ, kHz, mµVA), function indicators (LANPHONE, AUTO, MAX, battery), and LAN test results (OPEN, SHORT, REVERSED, MISWIRE, SPLIT PAIRS, SHIELD).
- Buttuna FUNC: Selects different functions within a single rotary switch position (e.g., AC/DC, Diode/Continuity).
- Buttuna firxa: Jaqleb bejn il-modi ta' kejl awtomatiku tal-firxa u l-modi ta' kejl manwali tal-firxa.
- Buttuna MAX: Displays the maximum measured value.
- Buttuna ŻOMM: Jiffriża l-qari attwali tal-wiri.
- TEST Button (Blue): Initiates the LAN cable test.
- Backlight Button (Yellow): Jattiva jew jiddiżattiva d-dawl ta' wara tad-displej.
- Swiċċ li jdur: Used to select the desired measurement function (OFF, ~V, =V, Ω, Diode/Continuity, Hz, µA~, mA~, A~, Net Cable, NCV).
- Ġakkijiet tad-dħul:
- Ġakk 10A: Għal kejl tal-kurrent sa 10A.
- COM Jack: Input komuni (negattiv) għall-kejl kollu.
- VΩHzµAmA Jack: Input pożittiv għall-volumtage, resistance, frequency, diode, continuity, and current measurements up to 200mA.
Setup
Installazzjoni tal-batterija:
- Kun żgur li l-miter ikun MITFI.
- Sib il-kompartiment tal-batterija fuq wara tal-miter.
- Ħoll il-vit(i) taż-żamma u neħħi l-għatu tal-batterija.
- Insert two (2) AA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Erġa’ poġġi l-għatu tal-batterija u waħħalha bil-vit(i).
Konnessjoni tal-wajers tat-test:
- Għal ħafna kejl (voltage, resistance, frequency, diode, continuity, and current up to 200mA), insert the black test lead into the COM jack u ċ-ċomb aħmar tat-test fil- VΩHzµAmA jack.
- For high current measurements (up to 10A), insert the black test lead into the COM jack u ċ-ċomb aħmar tat-test fil- 10A jack.
Istruzzjonijiet Operattivi
Operazzjoni Ġenerali:
- Auto-Rang: The meter automatically selects the appropriate measurement range. Press the GANJA button to switch to manual ranging if desired.
- Żamma tad-Data: Agħfas il- ŻOMM buttuna biex tiffriża l-qari attwali fuq id-displej. Agħfas mill-ġdid biex tirrilaxxa.
- Dawl ta' wara: Press the yellow backlight button to illuminate the display for better visibility in low-light conditions. Press again to turn off.
- Mitfi Awtomatiku: Il-miter jintefa awtomatikament wara perjodu ta' inattività biex jikkonserva l-ħajja tal-batterija.
Multimeter Functions:
- DC Voltage Measurement (=V):
- Issettja l-iswiċċ li jdur fuq =V pożizzjoni.
- Connect the red test lead to the positive side of the circuit and the black test lead to the negative side.
- Aqra d-DC voltagIl-valur fuq il-wiri.
- AC Voltage Measurement (~V):
- Issettja l-iswiċċ li jdur fuq ~V pożizzjoni.
- Qabbad il-wajers tat-test mal-vultaġġ ACtagsors e.
- Aqra l-AC voltagIl-valur fuq il-wiri.
- DC/AC Current Measurement (µA=~, mA=~, A=~):
- Set the rotary switch to the appropriate current range (µA, mA, or A).
- Agħfas il- FUNC button to select DC or AC current.
- Connect the meter in series with the circuit. Ensure correct jack usage (VΩHzµAmA for µA/mA, 10A for A).
- Aqra l-valur attwali fuq id-displej.
- Kejl tar-Reżistenza (Ω):
- Issettja l-iswiċċ li jdur fuq Ω pożizzjoni.
- Kun żgur li ċ-ċirkwit ma jkollux l-enerġija qabel ma tkejjel ir-reżistenza.
- Qabbad il-wajers tat-test mal-komponent li għandu jitkejjel.
- Aqra l-valur tar-reżistenza fuq il-wiri.
- Kejl tal-Frekwenza (Hz):
- Issettja l-iswiċċ li jdur fuq Hz pożizzjoni.
- Qabbad il-wajers tat-test mas-sors tas-sinjal.
- Aqra l-valur tal-frekwenza fuq id-displej.
- Diode Test and Audible Continuity:
- Set the rotary switch to the Diode/Continuity position.
- Agħfas il- FUNC button to toggle between Diode Test and Continuity Test.
- For Diode Test: Connect the red lead to the anode and black lead to the cathode. Read the forward voltage drop. Reverse leads for reverse bias.
- For Continuity Test: Connect leads across the circuit. An audible beep indicates continuity (low resistance).
- Mhux Kuntatt VoltagSejbien ta' e (NCV):
- Issettja l-iswiċċ li jdur fuq NCV pożizzjoni.
- Move the top part of the meter near a live AC voltagsors e.
- The meter will beep and the NCV indicator will light up when AC voltage jiġi skopert.
LAN Tester Function:
The MS8235 can test RJ45 (Ethernet) and RJ11/RJ12 (Phone) cables for common wiring faults.
- Issettja l-iswiċċ li jdur fuq Kejbil tan-Netwerk pożizzjoni.
- Connect one end of the network cable to the RJ45 port on the top of the meter.
- Connect the other end of the network cable to the remote unit (if applicable, not explicitly mentioned but implied for full testing).
- Agħfas il-blu TEST button to initiate the cable test.
- The display will show the status of each wire pair (1-8 and Shield) indicating: Miftuħa (broken wire), QASIRA (short circuit), MREVERU (reversed pair), MISWIRE (incorrect wiring), or PARI MAQSUM (pairs split between different connectors).
- For phone cables, the display will indicate RED-TIP u RED-RING status.
Manutenzjoni
Sostituzzjoni tal-batterija:
When the 'Low Battery' indicator appears on the display, replace the batteries as described in the 'Setup' section to ensure accurate measurements and proper operation.
Tindif:
Imsaħ il-marka tal-miterasing b'reklamaramp drapp u deterġent ħafif. Tużax abrażivi jew solventi. Kun żgur li l-miter ikun niexef għalkollox qabel l-użu.
Issolvi l-problemi
- L-ebda Wiri/Il-Miter Mhux Mixgħul: Iċċekkja l-installazzjoni tal-batterija u kun żgur li l-batteriji huma friski.
- Qari mhux eżatt: Ensure the correct function is selected on the rotary switch. Check test lead connections. Replace batteries if the 'Low Battery' indicator is on.
- LAN Test Errors: Ensure both ends of the cable are properly connected. Verify the cable type (RJ45/RJ11) matches the test.
- No NCV Detection: Ensure the rotary switch is set to NCV. The NCV function detects AC voltage; it will not respond to DC voltage.
Speċifikazzjonijiet
| Speċifikazzjoni | Valur |
|---|---|
| DC Voltage | 600V |
| AC Voltage | 600V |
| Kurrent DC | 10A |
| Kurrent AC | 10A |
| Reżistenza | 20MΩ |
| Frekwenza | 20kHz |
| LCD Display Count | 2000 |
| Klassifikazzjoni tas-Sigurtà | CAT. III 600V (IEC61010-1) |
| Sors tal-Enerġija | 2 batteriji AA (inklużi) |
| Dimensjonijiet | 9.37 x 5.04 x 2.36 pulzieri |
| Piż | 1.35 Liri |
| Numru tal-Mudell tal-Oġġett | MS8235 |
| UPC | 815108010734 |
Garanzija u Appoġġ
Mastech products are manufactured to high quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official Mastech websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal talbiet ta' garanzija.