Robinair RG6

Manwal tal-Utent tal-Magna Portabbli għall-Irkupru tar-Refriġerant Robinair RG6

1. Introduzzjoni u Fuqview

The Robinair RG6 is a portable refrigerant recovery machine designed for efficient and reliable refrigerant recovery in various conditions, including high temperatures. It features a rugged construction, a twin-cylinder oil-less compressor, and an oversized condenser for optimal performance. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your RG6 unit.

Robinair RG6 Portable Refrigerant Recovery Machine

Figure 1: Robinair RG6 Portable Refrigerant Recovery Machine

2. Informazzjoni dwar is-Sigurtà

WARNING: To prevent personal injury and/or equipment damage, read and understand the operating manual prior to operation.

  • Always wear proper personal protective equipment, including safety glasses and gloves. Do not breathe refrigerant vapor or mist.
  • Use this equipment in a well-ventilated area. If possible, operate the unit on the floor or at least 18 inches above the floor.
  • Always disconnect power from the unit prior to servicing.
  • Always use a DOT-approved recovery cylinder. Overfilling a cylinder (beyond 80% volume) can cause an explosion.
  • Do not exceed the pressure rating of the recovery cylinder.
  • Do not mix refrigerant types through a system or a container.
  • Always use a grounded 3-wire extension cord. A 12 AWG extension cord must be 14 AWG minimum and no longer than 25 feet.
  • Do not use this equipment in the vicinity of spilled or open containers of gasoline.
  • The machine is equipped with a high-pressure safety shut-off switch that automatically shuts off the machine if pressure rises above 550 PSI.

Dan il-prodott jista' jkun fih kimiċi magħrufa mill-Istat ta' California li jikkawżaw kanċer u difetti fit-twelid jew ħsara riproduttiva oħra. Għal aktar informazzjoni, żur www.P65Warnings.ca.gov.

3. Karatteristiċi tal-prodott

  • Disinn b'żewġ Ċilindri: Provides best-in-class recovery performance.
  • Oil-less Compressor: Capable of handling both liquid and vapor recovery.
  • Oversized Condensers and Fan: Larger condenser area and fan allow for maximum cooling and shorter cycle times.
  • High Pressure Safety Shut-off Switch: Automatically shuts off machine if pressure rises above 550 PSI.
  • Self-Purge Feature: Eliminates potential for cross-contamination and saves time.
  • Easy to Operate, Rugged Case: Features oversized pressure gauges, a comfortable handle, and simple controls.
  • Handles Almost All Refrigerants: Works with all common CFC, HFC, HCFC Refrigerants, including R-410A.
  • IEC Connector and Power Cord: Standardized power connection.
Quddiem view of Robinair RG6 showing gauges and controls

Figure 2: Front panel with gauges and controls.

4. Setup

  1. Ensure the recovery machine's inlet and outlet valves are closed.
  2. Connect the purge valve to the RECOVER position.
  3. Connect the inlet port of the recovery machine to the system being serviced using appropriate hoses.
  4. Connect the outlet port of the recovery machine to a DOT-approved recovery cylinder.
  5. Kun żgur li l-konnessjonijiet kollha huma sikuri biex tevita t-tnixxijiet.
  6. Connect the power cord to the machine and a grounded 115V AC, 60 Hz power outlet.
Qiegħ view of Robinair RG6 with quick start guide and warning label

Figure 3: Quick Start Guide and Safety Warnings on the unit.

5. Istruzzjonijiet Operattivi

5.1. Refrigerant Recovery

  1. After completing the setup, open the liquid and vapor valves on the system being serviced.
  2. Open the outlet valve on the recovery cylinder.
  3. Turn the recovery machine ON.
  4. Slowly open the inlet valve on the recovery machine.
  5. Allow the machine to run until the desired vacuum is achieved. If the machine stalls, immediately close the inlet valve to prevent damage.

5.2. Self-Purge Feature

The self-purge feature helps eliminate potential cross-contamination between different refrigerants and saves time.

  1. After completing refrigerant recovery, close the inlet valve on the recovery machine.
  2. Change the purge valve from RECOVER to PURGE.
  3. Allow the machine to run until the desired vacuum is achieved.
  4. Note: The outlet valve on the recovery cylinder must remain open during the self-cleaning process.

5.3. Compatible Refrigerants

The RG6 is designed to work with a wide range of refrigerants, including:

  • CFCs
  • HFCs
  • HCFCs
  • R-410A

6. Manutenzjoni

  • Skrin tal-Filtru: Regularly clean or replace the inlet filter screen to ensure optimal performance and prevent impurities from entering the machine.
  • Tindif Ġenerali: Keep the exterior of the machine clean and free from debris.
  • Ħażna: Aħżen il-magna f'ambjent niexef u nadif meta ma tkunx qed tintuża.

7 Issolvi l-problemi

  • Machine Stalls: If the machine stalls during recovery, immediately close the inlet valve to prevent damage. Check for excessive liquid refrigerant entering the machine or a clogged filter screen.
  • High Pressure Shut-off: If the machine shuts off due to high pressure (above 550 PSI), check for blockages in the outlet hose or an overfilled recovery cylinder. Allow the machine to cool before restarting.
  • Slow Recovery: Ensure all valves are fully open, hoses are correctly connected, and the filter screen is clean. Consider using larger diameter hoses for improved flow.

8. Speċifikazzjonijiet

SpeċifikazzjoniValur
BrandRobinair
MudellRG6
Piż tal-oġġett27 liri
Karatteristiċi SpeċjaliPortabbli
Voltage115 Volts
Frekwenza60 Hz
Kompressur3/4 HP, Twin-Cylinder, Oil-less
Dimensjonijiet17 L x 9 W x 12 H pulzieri

9. X'hemm fil-Kaxxa

  • Robinair RG6 Portable Refrigerant Recovery Machine

10. Garanzija u Appoġġ

Robinair, a Bosch Automotive Service Solutions brand, is committed to quality and performance. For warranty information, technical support, or service inquiries, please refer to the documentation included with your product or visit the official Robinair websit.

Robinair is recognized worldwide as a leader in AC/R evacuation tools and equipment.

Dokumenti Relatati - RG6

Preview Manwal tal-Istruzzjonijiet tal-Magna Robinair 34998 R-134a Sistema A/C Irkupru, Riċiklaġġ, Riċarġjar
Dan il-manwal jipprovdi struzzjonijiet dettaljati għat-tħaddim, il-manutenzjoni, u s-soluzzjoni tal-problemi tal-magna Robinair Mudell 34998, iddisinjata għall-irkupru, ir-riċiklaġġ, u l-iċċarġjar mill-ġdid tas-sistemi tal-arja kondizzjonata tal-karozzi R-134a. Jinkludi prekawzjonijiet ta' sigurtà, proċeduri ta' setup, linji gwida għat-tħaddim, skedi ta' manutenzjoni, u gwida għas-soluzzjoni tal-problemi.
Preview Robinair AC1234-9: Manwal tal-Istruzzjonijiet tal-Magna tas-Servizz tal-A/C R1234yf
Dan il-manwal tal-istruzzjonijiet jipprovdi gwida operattiva dettaljata għar-Robinair AC1234-9, magna professjonali ddisinjata għall-irkupru, ir-riċiklaġġ, u l-iċċarġjar mill-ġdid tar-refriġerant R1234yf f'sistemi ta' arja kondizzjonata tal-karozzi, li tissodisfa l-istandards SAE J2843.
Preview Manwal tat-Tħaddim tal-Unità ta' Rkupru, Riċiklaġġ u Iċċarġjar tar-Refriġerant Robinair 17800B/17801B
Dan il-manwal tat-tħaddim jipprovdi struzzjonijiet komprensivi għall-Unità ta' Rkupru, Riċiklaġġ u Rikarigu tar-Refriġerant Robinair 17800B/17801B. Ikopri s-setup, it-tħaddim, il-manutenzjoni, il-linji gwida tas-sigurtà, u s-soluzzjoni tal-problemi għas-sistemi tal-A/C tal-karozzi.
Preview ROBINAIR 16330 Kit Prinċipali għall-Iskoperta ta' Tnixxijiet UV HVAC/R
Gwida komprensiva għar-ROBINAIR 16330 UV Leak Detection HVAC/R Master Kit, li jinkludi teknoloġija LED UV vera għal skoperta effiċjenti ta' tnixxijiet f'sistemi ta' tisħin, ventilazzjoni, arja kondizzjonata, u refriġerazzjoni. Tinkludi l-kontenut tal-kit, l-ispeċifikazzjonijiet, u aċċessorji fakultattivi.
Preview Robinair CoolTech 34788-1 R-134a A/C Service Station - Prodott Fuqview
Informazzjoni dettaljata dwar ir-Robinair CoolTech 34788-1, stazzjon tas-servizz tal-A/C R-134a kompletament awtomatiku li jirkupra, jirriċikla, jevakwa, jittestja t-tnixxija, u jiċċarġja mill-ġdid is-sistemi tal-arja kondizzjonata tal-vetturi bi preċiżjoni u effiċjenza superjuri, konformi mal-istandards SAE J2788.
Preview Lista ta' Kontroll tal-Manutenzjoni ta' Qabel l-Istaġun tal-Magna Robinair
Lista ta' kontroll komprensiva għat-twettiq ta' manutenzjoni u kontrolli ta' qabel l-istaġun fuq it-tagħmir tas-servizz Robinair HVAC, li tkopri l-ispezzjoni tal-magna, il-ħajja tal-filtru, iż-żejt tal-pompa tal-vakwu, il-kalibrazzjoni tal-iskala, il-kontrolli tat-tnixxijiet, l-aġġornamenti tas-softwer, u l-manutenzjoni tal-identifikatur tar-refriġerant. Tinkludi numri tal-mudelli u numri tal-partijiet.