1. Introduzzjoni
This manual provides essential instructions for the safe installation, operation, and maintenance of your Planar 2D Diesel Air Heater. This 12-volt, 2 kW (7,000 BTU/hr) heater is designed to provide efficient heating for various applications, including trucks, RVs, boats, and cabins. Please read this manual thoroughly before installation and use to ensure proper function and safety.
2. Prodott Aktarview
The Planar 2D Diesel Air Heater kit includes the main heater unit and various components necessary for installation and operation. Familiarize yourself with all parts before beginning the installation process.

Figure 2.1: The main Planar 2D Diesel Air Heater unit. This compact unit is responsible for combustion and heat exchange.

Figura 2.2: Pjan komprensiv view of the Planar 2D Diesel Air Heater kit contents, including the heater unit, wiring, fuel pump, fuel line, exhaust, intake, and control panel.
Kit Components (Typical)
- Unità tal-Heater Prinċipali
- Pompa tal-Fjuwil
- Linja tal-Fjuwil
- Ċineg tal-Wajers
- Pajp tal-egżost
- Pajp tad-Dħul ta' l-Arja
- Tubi ta' l-Arja sħuna
- Vent Outlet Air
- Control Panel (e.g., PU 5, PU 16, or PU 22)
- Ħardwer tal-Immuntar
Nota: The muffler, external temperature sensor, and fuel tank are typically mhux inklużi in the standard kit and must be sourced separately if required for your installation.

Figure 2.3: Detail of the air outlet vent and flexible ducting, which directs heated air into the desired space.
3. Informazzjoni dwar is-Sigurtà
Operating a diesel heater involves combustion and electrical components. Adhere to all safety guidelines to prevent injury or damage.
- Ventilazzjoni: Ensure adequate ventilation for the heater's combustion air intake and exhaust. Never operate the heater in an enclosed, unventilated space.
- Eżawriment: The exhaust gases contain carbon monoxide, which is odorless and deadly. Always route the exhaust pipe securely to the outside, away from any air intakes or windows.
- Karburant: Use only diesel fuel. Handle fuel with care, away from open flames or ignition sources. Ensure all fuel connections are leak-free.
- Elettriku: Connect the heater to a stable 12-volt DC power source with appropriate fusing. Incorrect wiring can cause electrical fires or damage to the unit.
- Immuntar: Mount the heater securely to a stable, non-combustible surface. Maintain adequate clearance from flammable materials.
- Tfal u Pets: Keep children and pets away from the heater during operation, as surfaces can become hot.
- Manutenzjoni: Perform regular maintenance as described in this manual. Do not attempt repairs beyond your technical capability.
4. Installazzjoni
Proper installation is crucial for the safe and efficient operation of your Planar 2D heater. While installation can be straightforward, professional installation is recommended if you are unsure about any steps.
4.1. Ippjanar tal-Installazzjoni
- Post: Choose a dry, protected location for the heater unit, ensuring sufficient space for air circulation and access for maintenance. Consider the routing of fuel lines, exhaust, intake, and hot air ducts.
- Wiċċ tal-Immuntar: The mounting surface must be robust enough to support the heater's weight and vibrations. Use the provided mounting plate and hardware.
- Approvazzjonijiet: Maintain minimum clearances around the heater from combustible materials as specified in the technical drawings.

Figure 4.1: Technical drawing illustrating the dimensions and mounting points of the Planar 2D heater unit. Refer to these measurements for precise installation planning.
4.2. Gwida għall-Installazzjoni Pass Pass
- Immonta l-Heater: Secure the main heater unit to the chosen surface using the mounting plate and hardware. Ensure it is level and stable.
- Install Fuel System:
- Connect the fuel pump to the vehicle's fuel tank or a dedicated fuel tank (not included).
- Route the fuel line from the tank to the fuel pump, and then from the fuel pump to the heater unit. Ensure all connections are tight and leak-free.
- Mount the fuel pump securely, typically at an angle to allow air bubbles to escape.
- Connect Electrical System:
- Connect the main power harness to a fused 12-volt DC power source (e.g., vehicle battery). Ensure proper polarity.
- Connect the control panel wiring harness to the heater unit and mount the control panel in an accessible location.
- Install Air Intake and Exhaust:
- Attach the air intake pipe to the heater and route it to a clean air source, away from exhaust fumes.
- Attach the exhaust pipe to the heater and route it securely to the outside, ensuring it is clear of any obstructions and directed away from living spaces or air intakes.
- Install Hot Air Ducting:
- Connect the hot air ducting to the heater's hot air outlet.
- Route the ducting to the area you wish to heat and install the air outlet vent.
- Kontrolli Finali: Double-check all connections (fuel, electrical, air, exhaust) for security and leaks. Ensure no wires or pipes are pinched or exposed to excessive heat.
5. Istruzzjonijiet Operattivi
Once installed, operating your Planar 2D heater is straightforward using the control panel.

Figure 5.1: The digital control panel (e.g., PU-5, PU-16, or PU-22) used to operate the Planar 2D heater, featuring a display and control buttons.
5.1. Initial Startup (Priming)
Before the first use, or after running out of fuel, the fuel system needs to be primed to remove air. This is typically done through a specific function on the control panel or by repeatedly attempting to start the heater until fuel reaches the combustion chamber. Refer to your specific control panel's manual for detailed priming instructions.
5.2. Operazzjoni Bażika
- Qawwa Mixgħul: Press the power button on the control panel. The display will illuminate.
- Issettja t-Temperatura/Qawwa: Use the up/down arrows or rotary knob (depending on control panel model) to set the desired temperature or heating power level.
- Ċiklu tat-Tisħin: The heater will initiate its startup sequence, which includes pre-heating, fuel injection, ignition, and fan operation. This process may take a few minutes.
- Itfi: To turn off the heater, press the power button again. The heater will enter a cool-down cycle to prevent overheating, during which the fan will continue to run for a few minutes before shutting down completely. Do not disconnect power during the cool-down cycle.
Nota dwar il-Wiri tat-Temperatura: The control unit typically displays temperature in Celsius. There may not be an option to switch to Fahrenheit.
6. Manutenzjoni
Regular maintenance ensures the longevity and efficient performance of your Planar 2D heater.
- Spezzjoni Viżwali (Kull Xahar): Check all fuel lines, electrical connections, and air ducts for signs of wear, damage, or leaks. Ensure the exhaust pipe is clear and securely fastened.
- Intake ta' Arja Nadifa: Ensure the air intake for combustion is free from dust, debris, or obstructions.
- Clean Exhaust Outlet: Periodically check and clean the exhaust outlet to prevent carbon buildup, which can restrict airflow and affect performance.
- Filtru tal-Fjuwil: If your installation includes an inline fuel filter, inspect and replace it as recommended by the filter manufacturer.
- Batterija Voltage: Ensure your 12V power source maintains adequate voltage, especially during startup, as low voltage can prevent ignition.
7 Issolvi l-problemi
This section addresses common issues you might encounter with your Planar 2D heater.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Heater does not start/ignite | Low fuel level, air in fuel line, low battery voltage, clogged fuel filter, faulty glow plug. | Check fuel level, prime fuel system, check battery voltage, replace fuel filter, inspect glow plug (professional service recommended). |
| Heater produces white smoke | Incomplete combustion, low fuel pressure, incorrect air/fuel mixture, faulty glow plug. | Check fuel supply, ensure proper voltage, clean air intake/exhaust, professional inspection. |
| Heater produces black smoke | Excessive fuel, restricted air intake, clogged exhaust. | Check air intake for obstructions, clean exhaust, ensure correct fuel pump operation. |
| Heater shuts down unexpectedly | Overheating, low voltage, fuel supply interruption, error code. | Check for obstructions around heater, ensure proper ventilation, check battery/power supply, check control panel for error codes. |
| Control panel displays error code | Specific fault detected by the heater's diagnostic system. | Refer to your specific control panel's manual for a list of error codes and their meanings. |
If you are unable to resolve an issue, contact a qualified technician or the seller for assistance.
8. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Brand | Pjanari |
| Numru tal-Mudell | Planar 2D/12volt |
| Numru tal-Parti | 2D |
| Qawwa tat-Tisħin | 2 kW / 7,000 BTU/hr |
| Sors tal-Enerġija | 12V DC (Diesel fuel) |
| Piż tal-oġġett | 14.99 pounds (approximate, may include packaging) |
| Dimensjonijiet tal-Prodott | 127.36 x 46.77 x 47.05 inches (Note: These dimensions appear to be for the shipping package, not the heater unit itself. Refer to technical drawings for unit dimensions.) |
| L-ewwel Disponibbli | 1 ta’ Diċembru 2014 |
9. Garanzija u Appoġġ
For information regarding the warranty period, terms, and conditions for your Planar 2D Diesel Air Heater, please contact the original seller or authorized distributor. Keep your proof of purchase for any warranty claims.
For technical support or service inquiries, refer to the contact information provided by your seller or the manufacturer's official channels.