This manual provides essential instructions for the safe and effective operation, maintenance, and care of your NutriBullet Rx N17-1001 Blender. The NutriBullet Rx is designed to extract nutrients from various ingredients, creating smooth beverages, soups, and sauces using its 1700-watt motor and hands-free SMART technology.

Image: The NutriBullet Rx N17-1001 Blender system, including the power base, SouperBlast pitcher, and various cups.
2. Informazzjoni Importanti dwar is-Sigurtà
Please read all safety warnings and instructions before operating the NutriBullet Rx N17-1001 Blender. Failure to follow these instructions may result in injury or damage to the appliance.
- Sigurtà Elettrika: Always plug the appliance into a grounded electrical outlet. Do not immerse the power base, cord, or plug in water or other liquids. Unplug the blender when not in use, before assembling or disassembling parts, and before cleaning.
- Sigurtà tax-xafra: The Extractor Blade is sharp. Handle with care. Never touch the blades while the appliance is operating. Ensure the blade is securely attached to the cup or pitcher before placing it on the power base.
- Likwidi Sħan: When using the heating cycle for soups or sauces, ensure the SouperBlast Pitcher with Vented Lid is used. Do not fill above the MAX line. Hot ingredients can create pressure, so always use caution.
- Mili żejjed: Do not overfill cups or pitchers beyond the MAX line. Overfilling can lead to leakage and potential damage to the motor.
- Tagħbija żejda tal-Mutur: If the motor stops during operation, unplug the unit and allow it to cool for 15 minutes before attempting to use it again.
- Tfal: Keep the appliance and its cord out of reach of children. This appliance is not intended for use by children.
- Ħsara: Do not operate any appliance with a damaged cord or plug, or after the appliance malfunctions or has been dropped or damaged in any manner. Contact customer service for repair or replacement.
3. X'inhu Inkluż
Your NutriBullet Rx N17-1001 Blender package includes the following components:
- 1700W High-Torque Power Base
- Estrattur Xafra
- SouperBlast Pitcher with 2-piece Vented Lid (1 liter capacity)
- 45 oz Oversized Cup with Pitcher Lid
- 30 oz Short Cup
- Ċirku tax-Xufftejn tal-Kumdità
- Stay-Fresh Lid
- Għodda għat-Tneħħija tax-Xafra
- Gwida għall-Utent
- Nature's Prescription Book (Recipe Book)

Image: A visual representation of all components included in the NutriBullet Rx N17-1001 Blender package.
4. Setup
- Ippakkja: Neħħi l-komponenti kollha mill-imballaġġ bir-reqqa. Żomm l-imballaġġ għal ħażna jew trasport fil-futur.
- Naddaf: Before first use, wash all cups, pitchers, lids, and the Extractor Blade in warm, soapy water. Rinse thoroughly and dry. The power base should only be wiped with a damp drapp.
- Pjazzament: Place the 1700W High-Torque Power Base on a clean, dry, and level surface. Ensure there is adequate ventilation around the unit.
- Konnessjoni tal-Enerġija: Ipplaggja l-korda tad-dawl fi żbokk elettriku standard ta '110V AC.
5. Istruzzjonijiet Operattivi
5.1 Blending (NutriBlast Mode)
The NutriBullet Rx features hands-free SMART technology for optimal blending.
- Ipprepara l-ingredjenti: Add your desired ingredients (fruits, vegetables, nuts, seeds, liquids) into the 30 oz Short Cup, 45 oz Oversized Cup, or SouperBlast Pitcher. Do not exceed the MAX fill line.
- Waħħal ix-xafra: Twist the Extractor Blade onto the cup or pitcher until it is securely tightened.
- Poġġi fuq il-Bażi: Invert the cup/pitcher and place it onto the 1700W High-Torque Power Base. Align the tabs on the cup/pitcher with the slots on the base.
- Attiva: Press down firmly on the cup/pitcher and twist clockwise until the tabs lock into place. The blender will automatically start the NutriBlast cycle, which typically runs for approximately 1 minute.
- Waqqaf: The unit will automatically stop when the cycle is complete. To stop manually, twist the cup/pitcher counter-clockwise and lift it off the base.
- Servi: Carefully remove the Extractor Blade and enjoy your blended creation.

Image: The NutriBullet Rx N17-1001 Blender with a pitcher filled with fresh ingredients, demonstrating its blending function.
5.2 Heating Cycle (SouperBlast Mode)
The NutriBullet Rx includes a specialized heating cycle for preparing warm soups and sauces.
- Use SouperBlast Pitcher: This mode requires the SouperBlast Pitcher with the 2-piece Vented Lid. Ensure the vent cap is open during operation to allow steam to escape.
- Żid l-ingredjenti: Add your soup or sauce ingredients to the SouperBlast Pitcher. Do not exceed the MAX fill line.
- Waħħal ix-xafra: Twist the Extractor Blade onto the SouperBlast Pitcher until it is securely tightened.
- Poġġi fuq il-Bażi: Invert the pitcher and place it onto the Power Base.
- Activate Heating Cycle: The unit will detect the SouperBlast Pitcher and automatically initiate the heating cycle, which runs for approximately 7 minutes. The motor will pulse to blend and heat the contents.
- Waqqaf: The unit will automatically stop when the cycle is complete. To stop manually, twist the pitcher counter-clockwise and lift it off the base.
- Servi: Carefully remove the Extractor Blade. Use caution as contents will be hot.

Image: The NutriBullet Rx N17-1001 Blender in operation, demonstrating its heating function for soups and sauces.
6. Kura u Manutenzjoni
Proper cleaning and maintenance will ensure the longevity and optimal performance of your NutriBullet Rx.
- Bażi tal-Enerġija: Always unplug the power base before cleaning. Wipe the power base with a damp drapp. Tgħaddix fl-ilma jew f'xi likwidu ieħor.
- Cups, Pitchers, and Lids: All cups, pitchers, and lids are dishwasher-safe (top rack only). Alternatively, they can be hand-washed with warm, soapy water.
- Extractor Blade: The Extractor Blade should be hand-washed immediately after use. Rinse the blade under running water to remove any residue. Use the included cleaning brush for thorough cleaning around the blades. Do not place the Extractor Blade in the dishwasher, as this may dull the blades.
- Residwu iebsa: For stubborn residue, fill the cup/pitcher with warm water and a small amount of dish soap, then attach the blade and run the blender for a few seconds. This can help loosen stuck-on food.
- Ħażna: Store the NutriBullet Rx in a clean, dry place when not in use.

Image: A NutriBullet cup being rinsed under a faucet, illustrating the ease of cleaning.
7 Issolvi l-problemi
If you encounter issues with your NutriBullet Rx, refer to the following common troubleshooting steps:
- Blender Does Not Turn On:
- Kun żgur li l-korda tal-enerġija hija mdaħħla sew f'sokit elettriku li jaħdem.
- Verify that the cup/pitcher is properly seated and twisted onto the power base, engaging the activation tabs.
- The unit may have overheated. Unplug and allow it to cool for 15 minutes before attempting to use again.
- Leaking During Operation:
- Check that the Extractor Blade is securely twisted onto the cup/pitcher.
- Ensure ingredients do not exceed the MAX fill line.
- Spezzjona l-gasket tax-xafra għal ħsara jew għal qagħda mhux xierqa.
- Ingredients Not Blending Smoothly:
- Add more liquid to facilitate blending.
- Ensure ingredients are cut into smaller pieces, especially hard items.
- Do not overfill the cup/pitcher.
- Storbju Qawwi jew Riħa ta' Ħruq:
- Unplug the unit immediately. This may indicate a motor overload or mechanical issue. Allow to cool. If the issue persists, contact customer support.
For further assistance, please refer to the official user guide or contact NutriBullet customer support.
8. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Brand | NutriBullet |
| Mudell | N17-1001 |
| Kulur | Iswed |
| Qawwa tal-Mutur | 1700 Watts |
| Kapaċità | SouperBlast Pitcher: 1 Liter (approx. 33.8 oz), 45 oz Oversized Cup, 30 oz Short Cup |
| Dimensjonijiet tal-Prodott (LxWxH) | 6.3"D x 7.05"W x 18.5"H |
| Voltage | 110 Volts |
| Materjal tax-xafra | Stainless Steel |
| Numru ta' Veloċitajiet | 1 (with SMART technology cycles) |
| Karatteristika Speċjali | Hands-free SMART Technology, Heating Cycle |
| Piż tal-oġġett | 1 Pound (Power Base) |
9. Garanzija u Appoġġ
The NutriBullet Rx N17-1001 Blender comes with a Garanzija Limitata. For specific details regarding warranty coverage, duration, and terms, please refer to the official User Guide included with your product or visit the NutriBullet official websit.
For technical support, replacement parts, or any other inquiries, please contact NutriBullet customer service. Contact information can typically be found in your User Guide or on the manufacturer's websit.