Uponor 1013006

Manwal tal-Istruzzjonijiet tal-Attwatur Termali Uponor ST230, 230V, Mudell 1013006

1. Introduzzjoni

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Uponor Thermal Actuator ST230, 230V, Model 1013006. Please read these instructions carefully before proceeding with installation or use. Retain this manual for future reference.

2. Prodott Aktarview

The Uponor Thermal Actuator ST230, 230V, Model 1013006 is designed for controlling the return valves on Uponor Vario S manifolds in underfloor heating systems. It operates on 230 Volts and features a screw connection IG M 30 x 1.5, a stroke indicator, and a 1.0-meter connection cable with wire end ferrules. The unit is splash-proof with an IP54 rating and is CE and RoHS certified.

Uponor Thermal Actuator ST230, 230V, Model 1013006

Figura 2.1: Uponor Thermal Actuator ST230, 230V, Model 1013006. This image shows the blue housing of the actuator with the Uponor logo and the grey screw connection base.

3. Informazzjoni dwar is-Sigurtà

  • Installation and electrical connections must be performed by a qualified electrician or authorized personnel in accordance with local regulations and standards.
  • Ensure the main power supply is disconnected before performing any installation, maintenance, or troubleshooting.
  • Do not open the actuator housing. There are no user-serviceable parts inside.
  • Protect the device from direct water spray or immersion, despite its splash-proof rating.
  • Use only genuine Uponor components and accessories.

4. Setup u Installazzjoni

The thermal actuator is designed for easy mounting on Uponor Vario S manifold return valves. Follow these steps for proper installation:

  1. Ensure the heating system is depressurized and the manifold valves are in the correct position for actuator mounting.
  2. Carefully screw the actuator onto the valve connection (IG M 30 x 1.5) by hand until it is securely fastened. Do not overtighten.
  3. Connect the 230V electrical cable to the appropriate control unit or thermostat terminals. The cable is 0.75 mm² x 1.0 m and comes with wire end ferrules for secure connection.
  4. Verify all connections are secure and correctly wired according to the system's electrical diagram.
Diagram of Uponor Thermal Actuator with cable

Figura 4.1: Diagram showing the Uponor Thermal Actuator with its integrated connection cable. This illustrates the actuator's form factor and cable exit point.

Dimensional drawing of Uponor Thermal Actuator

Figura 4.2: Dimensional drawing of the Uponor Thermal Actuator, indicating key measurements (do, h, G) for installation planning. 'do' represents the outer diameter, 'h' the height, and 'G' the thread size.

5. Istruzzjonijiet Operattivi

The Uponor Thermal Actuator operates automatically in conjunction with a room thermostat or heating control system. When the control system signals a demand for heat, the actuator receives power, causing its internal element to expand and open the valve. When the heat demand is met, power is removed, and the actuator cools, closing the valve.

  • Stroke Indicator: The actuator is equipped with a stroke indicator, typically a small pin or window, which visually confirms the valve's open or closed position. Observe this indicator to verify proper operation.
  • Operazzjoni Inizjali: After installation and power-up, allow a short period for the actuator to respond to the control signal and fully open or close the valve.

6. Manutenzjoni

The Uponor Thermal Actuator ST230, 230V, Model 1013006 is designed for maintenance-free operation. No regular servicing or lubrication is required.

  • Keep the exterior of the actuator clean and free from dust or debris. Use a soft, dry cloth for cleaning.
  • Tużax tindif jew solventi li joborxu.
  • Periodically check the electrical connections for any signs of wear or damage.

7 Issolvi l-problemi

If the thermal actuator is not functioning as expected, consider the following:

  • Actuator not opening/closing:
    • Check if the control system (thermostat) is calling for heat.
    • Verify that the actuator is receiving 230V power.
    • Ensure electrical connections are secure and correct.
    • Confirm the actuator is correctly screwed onto the valve.
  • No visible movement of stroke indicator:
    • Allow sufficient time for the actuator to react (thermal actuators have a delay).
    • Check power supply and control signal.

If issues persist after checking these points, contact qualified service personnel.

8. Speċifikazzjonijiet

Uponor Thermal Actuator ST230, 230V, Model 1013006 Technical Data Sheet

Figura 8.1: Technical data sheet for the Uponor Thermal Actuator ST230, 230V, Model 1013006, providing detailed specifications and contact information.

SpeċifikazzjoniValur
BrandUponor
Numru tal-Mudell1013006
ManifatturUponor
Dimensjonijiet tal-Prodott (L x W x H)5 x 5 x 7.5 ċm
Piż120 Gramm
Voltage230 Volts
Vol massimutage230 Volts
Tip ta' KonnetturSpade
Kuntatt MaterjalStainless Steel
Materjal ta 'insulazzjoniPolyolefin
Tip ta' TerminalSpade Terminal
Speċifikazzjonijiet KonformiCE, RoHS
Pajjiż ta' Oriġiniil-Ġermanja
Kodiċi Internazzjonali tal-Artiklu (EAN)04021598002937
Kejbil tal-Konnessjoni0.75 mm² x 1.0 m, without plug, with wire end ferrules
Klassi ta' ProtezzjoniIP54 (li ma titlaqx)
Konnessjoni tal-valvScrew connection IG M 30 x 1.5
KaratteristikaIndikatur tal-puplesija

9. Garanzija u Appoġġ

Uponor products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Uponor directly. Information regarding spare parts availability is not provided in the product specifications.

Informazzjoni ta' Kuntatt:

Uponor GmbH

Industriestraße 56

97437 Hassfurt

il-Ġermanja

Telefon: +4932210090856

Email: Kundenservice@uponor.com

Websit: www.uponor.com/de-de

Dokumenti Relatati - 1013006

Preview Uponor Underfloor Heating and Cooling: Planning Information Guide
This comprehensive planning guide from Uponor details underfloor heating and cooling systems, covering technical specifications, design criteria, installation procedures, and hydraulic balancing for optimal climate control solutions.
Preview Uponor Vario / Vario PLUS Actuator Installation and Technical Manual
Comprehensive guide to the Uponor Vario and Vario PLUS actuators, covering installation, operation, features like 'First-Open', and detailed technical specifications for HVAC systems.
Preview Manwal tal-Installazzjoni tal-Uponor Classic
Dan il-manwal jipprovdi struzzjonijiet dettaljati għall-installazzjoni tas-sistema Uponor Classic, inkluż it-tqegħid tal-pajpijiet, il-konnessjoni tal-manifold, u l-ittestjar tal-pressjoni. Ikopri passi essenzjali għal installazzjoni b'suċċess u effiċjenti tas-sistema tat-tisħin tal-art Uponor Classic.
Preview Uponor Vario Retrofit Actuator: Installation Guide and Technical Specifications
Comprehensive guide to installing and operating the Uponor Vario retrofit actuator, including detailed technical specifications, compatibility information, and safety instructions for HVAC systems.
Preview Uponor Siccus Mini: Speċifikazzjonijiet Tekniċi tas-Sistema ta' Tisħin u Tkessiħ Niexef taħt l-Art
Informazzjoni teknika komprensiva għas-sistema ta' tisħin u tkessiħ taħt l-art niexfa ta' għoli baxx Uponor Siccus Mini. Tkopri d-deskrizzjoni tas-sistema, il-benefiċċji, il-komponenti, l-ippjanar, l-installazzjoni, u l-ispeċifikazzjonijiet tekniċi dettaljati għall-modernizzazzjoni residenzjali.
Preview Gwida Rapida tal-Uponor Combi Port E-Hybrid - Installazzjoni u Tħaddim
Din il-gwida rapida tipprovdi informazzjoni essenzjali għall-installazzjoni u t-tħaddim tal-unità tal-interfaċċja tas-sħana Uponor Combi Port E-Hybrid. Tkopri s-sigurtà ġenerali, l-identifikazzjoni tal-komponenti, l-installazzjoni idrawlika u elettrika, il-mili, it-tlaħliħ, l-ittestjar, u l-proċeduri ta' spezzjoni viżwali.