1. Introduzzjoni
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Steinbach 040955 CPS 40-2 Filtration Pump. Please read these instructions carefully before using the pump to ensure proper function and longevity of the product. This pump is designed for filtering pool water up to approximately 19,000 liters capacity and is compatible with Steinbach Classic 300, Classic 250, and ActiveBalls+ filtration systems.
2. Istruzzjonijiet tas-Sigurtà
Always observe the following safety precautions to prevent injury or damage to the pump.
- Sigurtà Elettrika: Ensure the power supply matches the pump's specifications (240 Volts). Always disconnect the pump from the power supply before performing any maintenance or cleaning. Do not operate the pump with a damaged power cord or plug.
- Sigurtà tal-Ilma: Never operate the pump dry. Ensure the pump is fully primed with water before starting. Keep children and pets away from the pump during operation.
- Pjazzament: Install the pump on a stable, level surface. Ensure adequate ventilation around the pump to prevent overheating.
- Temperatura: The pump is designed for water temperatures up to 35 degrees Celsius.
3. Prodott Aktarview
The Steinbach 040955 CPS 40-2 is a robust filtration pump designed for efficient pool water circulation. It features a durable plastic housing and an electric cable power source. The pump is compact and operates quietly.

Figura 3.1: Quddiem view of the Steinbach 040955 CPS 40-2 Filtration Pump.

Figura 3.2: Ġenb view of the pump, showing the inlet and outlet connections.

Figure 3.3: Visual representation of the pump's dimensions, approximately 20 cm (8.2 inches) in height.

Figure 3.4: Product packaging displaying key specifications such as 230V/200W power, 6.5m max head, and 6000 l/h flow rate.
4. Setup
Follow these steps for proper installation of your filtration pump:
- Spakkjar: Neħħi l-komponenti kollha mill-imballaġġ bir-reqqa. Iċċekkja għal kwalunkwe ħsara.
- Pjazzament: Position the pump on a firm, level surface near your pool, ensuring it is protected from direct weather exposure and has adequate air circulation.
- Konnessjonijiet tal-manka: Connect the appropriate hoses (32mm or 38mm diameter) to the pump's inlet and outlet ports. Ensure all connections are secure and watertight to prevent leaks.
- Priming: Before starting, ensure the pump is fully primed with water. This typically involves filling the pump housing with water until it overflows from the suction port.
- Konnessjoni Elettrika: Connect the pump to a grounded electrical outlet (240V). Ensure the circuit is protected by a Residual Current Device (RCD) for safety.
5. Operazzjoni
Ladarba l-pompa tkun issettjata u pprajmata, tista' tibda toperaha:
- Tibda tal-Pompa: Turn on the power supply to the pump. The pump should start circulating water immediately.
- Monitoraġġ: Observe the water flow and pressure. The pump operates quietly, indicating efficient performance.
- Run Time: The optimal run time for your pump depends on your pool size and usage. Consult your pool system's guidelines for recommended daily filtration cycles.
- Tfigħ: To turn off the pump, simply disconnect it from the power supply.
6. Manutenzjoni
Regular maintenance ensures the longevity and efficiency of your filtration pump:
- Tindif: Periodically clean the pump's exterior with a damp drapp. Tużax kimiċi ħarxa.
- Filter System Maintenance: This pump works in conjunction with a filtration system. Regularly clean or replace the filter cartridges or media as recommended by your filter system's manual.
- Winterization: If you live in an area with freezing temperatures, disconnect the pump and drain all water from it before winter. Store the pump in a dry, frost-free location.
- Spezzjoni tal-pajp: Regularly check hoses and connections for wear, cracks, or leaks. Replace damaged components as needed.
7 Issolvi l-problemi
If you encounter issues with your pump, refer to the following common problems and solutions:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-pompa ma tibdax | Ebda provvista ta 'enerġija Is-sħana żejda tal-mutur Impeller iġġammjat | Iċċekkja l-konnessjoni tal-enerġija u s-circuit breaker Allow pump to cool down Disconnect power and inspect/clear impeller |
| Fluss ta 'ilma baxx | Pompa mhux ipprajmata Filtru misdud Tnixxija tal-arja fil-linja tal-ġbid | Erġa' ipprajmja l-pompa Naddaf jew ibdel il-filtru Check all suction line connections for tightness |
| Il-pompa hija storbjuża | Arja fis-sistema Debris fl-impeller Pompa taħdem niexfa | Fsada l-arja mis-sistema Disconnect power and clear debris Ensure pump is primed and has continuous water supply |
8. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Manifattur | Steinbach |
| Numru tal-Mudell | 040955 |
| Dimensjonijiet tal-Prodott (L x W x H) | 22.5 x 15.5 x 33.5 ċm (8.86 x 6.1 x 13.19 pulzieri) |
| Piż | 4 kg (8.82 lbs) |
| Rata tal-Fluss | 6000 l/siegħa (75 Litri kull minuta) |
| Max. Head Height | 6.5-il metru |
| Voltage | 240 Volts |
| Konsum tal-Enerġija | 200 Watts |
| Materjal | Plastik |
| Kulur | Iswed, Fidda |
| Dijametru tal-Konnessjoni tal-Pajp | 32mm / 38mm |
| Max. Temperatura tal-Ilma | 35 ℃ |
| Ċertifikazzjoni | Ċertifikat mingħajr frustrazzjoni |
| Kodiċi Internazzjonali tal-Artiklu | 9008748409551 |
9. Garanzija u Appoġġ
Specific warranty information for the Steinbach 040955 CPS 40-2 Filtration Pump is not explicitly provided in the product data. For any product-related inquiries, technical support, or warranty claims, please contact Steinbach customer service directly or refer to the official Steinbach website for detailed support information.