KYORITSU 5202

KYORITSU Digital Light Meter Model 5202

Manwal ta' Istruzzjoni

1. Introduzzjoni

Grazzi tax-xiriasing the KYORITSU Digital Light Meter Model 5202. This device is designed for accurate measurement of illuminance in various environments. It features a separated light receiving sensor for optimal positioning, multiple measurement ranges, and a clear digital display. Please read this manual thoroughly before use to ensure safe and correct operation.

2. Informazzjoni dwar is-Sigurtà

  • Do not attempt to open or modify the device, except for battery replacement as described in this manual.
  • Żomm l-apparat 'il bogħod mill-ilma, umdità għolja, u temperaturi estremi.
  • Evita li twaqqa 'l-apparat jew suġġett għal impatti qawwija.
  • Use only the specified battery type (9V alkaline battery).
  • Armi l-batteriji skont ir-regolamenti lokali.
  • Ensure the sensor is clean and free from obstructions for accurate readings.

3. Prodott Aktarview

The KYORITSU Digital Light Meter 5202 is a compact and versatile instrument for measuring light levels. Its key features include:

  • 3-Range Switching: Measures illuminance from low to high levels (200/2000/20000 lux).
  • Firxa Wiesgħa ta' Kejl: 0.1 to 19990 Lux.
  • Funzjoni ta' Żamma tad-Data: Jiffriża l-kejl attwali fuq id-displej.
  • Separated Sensor: The light receiving sensor is separate from the main unit, allowing for flexible and optimal positioning during measurement, preventing interference from the user's shadow.
  • Aġġustament tal-offset: Allows for fine-tuning of readings.
  • Display LCD kbir: Provides clear and easy-to-read digital measurements.
Quddiem view of the KYORITSU Digital Light Meter 5202, showing the LCD display, control buttons, and the attached light sensor. Dimensions are indicated as 6.1 inches (15 cm) in height.

Figura 1: Quddiem view of the KYORITSU Digital Light Meter 5202 with dimensions.

Wara view of the KYORITSU Digital Light Meter 5202, showing the integrated kickstand extended for tabletop use and the sensor cable connection.

Figura 2: Wara view of the KYORITSU Digital Light Meter 5202 with kickstand.

4. Setup

4.1 Installazzjoni tal-batterija

The device requires one 9V alkaline battery (included). To install or replace the battery:

  1. Kun żgur li l-apparat ikun mitfi.
  2. Sib il-kompartiment tal-batterija fuq wara tal-unità.
  3. Remove the three screws securing the bottom bracket/back cover.
  4. Carefully pry open the side seams of the main unit using a small flathead screwdriver. This will reveal the internal circuit board and the battery connection.
  5. Qabbad il-batterija ta' 9V mal-klipp tal-batterija, waqt li tosserva l-polarità korretta.
  6. Place the battery into its compartment and carefully reassemble the unit, ensuring the side seams align properly before re-inserting the screws.

4.2 Konnessjoni tas-Sensor

The light receiving sensor is permanently attached via a cable. Ensure the cable is not damaged or kinked before use.

5. Istruzzjonijiet Operattivi

5.1 Power On/Off

Agħfas il- QAWWA buttuna biex tixgħel jew titfi l-apparat.

5.2 Għażla tal-Medda

The device offers three measurement ranges: 200, 2000, and 20000 Lux. Select the appropriate range using the GANJA button. Start with a higher range if the light intensity is unknown to avoid over-range readings.

5.3 Teħid ta 'Kejl

  1. Ixgħel l-apparat.
  2. Position the light receiving sensor at the point where illuminance is to be measured. Ensure the sensor surface is clean and directly facing the light source.
  3. Select the appropriate measurement range.
  4. Read the illuminance value displayed on the LCD screen.

5.4 Funzjoni ta' Żamma tad-Data

Agħfas il- ŻOMM button to freeze the current reading on the display. Press it again to release the hold and resume live measurement.

5.5 Offset Adjustment

The device includes an offset adjustment feature. Refer to the detailed instructions in the full product catalog or contact customer support for advanced calibration procedures if precise offset adjustment is required.

6. Manutenzjoni

6.1 Tindif

Wipe the device and sensor with a soft, dry cloth. Do not use abrasive cleaners or solvents. Keep the sensor surface clean to ensure accurate readings.

6.2 Sostituzzjoni tal-batterija

Replace the 9V battery when the low battery indicator appears on the display or if the device fails to power on. Follow the steps outlined in Section 4.1 Battery Installation.

6.3 Ħażna

When not in use for extended periods, remove the battery to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

7 Issolvi l-problemi

  • L-apparat ma jixgħelx: Iċċekkja l-installazzjoni tal-batterija u kun żgur li l-batterija għandha biżżejjed ċarġ. Ibdel jekk meħtieġ.
  • Qari mhux preċiż: Ensure the sensor surface is clean and unobstructed. Verify the correct measurement range is selected. Check for any environmental factors affecting light.
  • Display shows 'OL' or 'OVER': The light intensity exceeds the selected range. Switch to a higher measurement range.
  • Id-displej huwa vojt jew qed jitteptep: Battery may be low or improperly installed. Replace the battery.

8. Speċifikazzjonijiet

KaratteristikaSpeċifikazzjoni
ManifatturKYORITSU
Numru tal-Mudell5202
Medda ta' Kejl0.1 sa 19990 Lux
Firxiet200 / 2000 / 20000 Lux
Piż tal-oġġett300 g
Dimensjonijiet tal-Prodott148(L) × 71(W) × 36(D) mm
Tip ta 'batterijaBatterija Alkalina 1 x 9V (inkluża)
Żamma tad-DataIva
Aġġustament OffsetIva
L-Ewwel Data Disponibbli (Amazon.co.jp)18 ta’ Marzu, 2014

9. Garanzija u Appoġġ

This product is covered by the manufacturer's standard warranty. For warranty claims, technical support, or service, please contact your local KYORITSU distributor or refer to the official KYORITSU websit għal informazzjoni ta' kuntatt. Jekk jogħġbok żomm il-prova tax-xiri tiegħek għal skopijiet ta' garanzija.

Dokumenti Relatati - 5202

Preview KEW 6305 Manwal ta 'Istruzzjoni tal-Miter tal-Enerġija Diġitali
Manwal ta' struzzjonijiet komprensiv għall-KYORITSU KEW 6305 Digital Power Meter, li jiddeskrivi l-karatteristiċi, l-operat, il-prekawzjonijiet ta' sigurtà u l-ispeċifikazzjonijiet tiegħu għal kejl preċiż tal-qawwa.
Preview Kyoritsu KEW SNAP 2033 Diġitali AC/DC Clamp Manwal ta' Istruzzjoni tal-Meter
Dan id-dokument jipprovdi struzzjonijiet komprensivi għat-tħaddim tal-Kyoritsu KEW SNAP 2033 Digital AC/DC Clamp Miter. Jinkludi twissijiet ta' sigurtà, karatteristiċi, speċifikazzjonijiet, proċeduri ta' kejl għall-kurrent AC u DC, funzjonijiet oħra bħal sleep u data hold, u linji gwida għas-sostituzzjoni tal-batterija.
Preview KEW2117R Ċliver Diġitaliamp Manwal ta' Istruzzjoni tal-Meter
Manwal ta' struzzjonijiet għall-Kyoritsu KEW2117R Digital Clamp Miter, li jagħti dettalji dwar il-prekawzjonijiet ta' sigurtà, l-ispeċifikazzjonijiet, il-proċeduri tal-kejl għall-kurrent AC/DC u l-volumtage, resistance, continuity, and other functions like NCV, data hold, and battery replacement.
Preview Manwal ta' Istruzzjoni tal-Multimetru Diġitali Kyoritsu KEW MATE 2012RA | AC/DC Clamp Sensor
Esplora l-multimetru diġitali Kyoritsu KEW MATE 2012RA b'vultaġġ AC/DC.amp sensur. Dan il-manwal komprensiv ta' struzzjonijiet ikopri twissijiet ta' sigurtà, speċifikazzjonijiet dettaljati, u gwidi għat-twettiq ta' kurrent AC/DC, voltagKejl ta' e, reżistenza, kontinwità, dijodi, kapaċitaturi, u frekwenza. Essenzjali għall-ittestjar elettriku u s-soluzzjoni ta' problemi.
Preview Kyoritsu 2434 Tnixxija Clamp Miter | Speċifikazzjonijiet u Karatteristiċi
Prodott fuqview u speċifikazzjonijiet għall-Kyoritsu 2434 Leakage Clamp Miter. Il-karatteristiċi jinkludu suxxettibilità baxxa għal kampi manjetiċi esterni, rispons ta' frekwenza wiesgħa, u riżoluzzjoni għolja. Jiġu pprovduti dettalji dwar il-firxiet tal-kejl tal-kurrent AC, id-daqs tal-konduttur, is-sors tal-enerġija, u d-dimensjonijiet.
Preview Manwal tal-Istruzzjonijiet tat-Testers tal-Kurrent tat-Tnixxija tas-Serje Kyoritsu KEW SNAP (2432/2433)
Manwal ta' struzzjoni għat-Testers tal-Kurrent tat-Tnixxija tas-Serje Kyoritsu KEW SNAP, Mudelli 2432 u 2433. Il-karatteristiċi jinkludu kejl tat-tnixxija tal-AC, cl diġitaliamp testing, IEC 61010-2-032 compliance, data hold, and peak hold functions.