Greisinger GPHU 014 MP/BNC pH Measurement Converter Instruction Manual

Model: GPHU 014 MP/BNC

1. Introduzzjoni

This manual provides comprehensive instructions for the safe and efficient operation of your Greisinger GPHU 014 MP/BNC pH Measurement Converter. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage. Keep this manual for future reference.

The GPHU 014 MP/BNC is designed to convert pH electrode signals into a standardized output, allowing for precise pH monitoring in various applications. It is intended for use with compatible pH electrodes featuring a BNC connector.

2. Informazzjoni dwar is-Sigurtà

  • Always operate the device within its specified environmental conditions.
  • Tesponix l-apparat għal temperaturi estremi, dawl tax-xemx dirett, jew umdità għolja.
  • Evita li twaqqa’ jew tissuġġetta l-apparat għal impatti qawwija.
  • Ensure proper electrical connections are made according to the instructions to prevent electrical shock or damage.
  • Tippruvax tiftaħ jew issewwi l-apparat int stess. Irreferi għal kull manutenzjoni f'idejn persunal kwalifikat.
  • Use only compatible pH electrodes and accessories with this converter.
  • Dispose of the device and any associated components in accordance with local environmental regulations.

3. Kontenut tal-Pakkett

Jekk jogħġbok iċċekkja l-kontenut tal-pakkett malli tirċevih. Jekk xi oġġetti huma nieqsa jew bil-ħsara, ikkuntattja lill-fornitur tiegħek immedjatament.

  • Greisinger GPHU 014 MP/BNC pH Measurement Converter
  • Manwal ta 'Istruzzjoni (dan id-dokument)
  • Mounting accessories (if applicable, check packaging)

Note: A pH electrode is not included with this converter and must be purchased separately.

4. Prodott Aktarview

The Greisinger GPHU 014 MP/BNC is a compact and robust pH measurement converter designed for industrial and laboratory applications. It features a clear digital display and intuitive controls for easy operation.

Greisinger GPHU 014 MP/BNC pH Measurement Converter front view

Figura 1: Quddiem view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter. The display shows "7.46 pH" and includes "ATC" and "Temp" indicators. Below the display are three buttons labeled "SET 1", "▼ 2", and "▲ 3". A BNC connector is visible on the right side for electrode connection. Two small ports are visible at the bottom.

Greisinger GPHU 014 MP/BNC pH Measurement Converter side view

Figura 2: Ġenb view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter, highlighting the BNC connector and the robust housing. The connector is labeled "AMPHENOL".

Komponenti Ewlenin:

  • Wirja Diġitali: Shows pH value, temperature, and status indicators.
  • SET Button (1): Użat biex jiddaħħlu u jikkonfermaw is-settings.
  • Buttuna 'l isfel (2): Used to navigate menus and decrease values.
  • Buttuna 'l fuq (3): Used to navigate menus and increase values.
  • Konnettur BNC: For connecting a compatible pH electrode.
  • Input ta' Enerġija: (Location not visible in images, refer to device for exact position)

5. Setup

5.1. Immuntar

The converter can be mounted using the integrated mounting points (screws visible in Figure 1). Ensure the mounting location is stable, free from excessive vibration, and within the specified operating temperature range.

5.2. Connecting the pH Electrode

  1. Ensure the converter is powered off.
  2. Carefully connect your pH electrode's BNC connector to the BNC input on the right side of the GPHU 014 MP/BNC converter (refer to Figure 1 and 2).
  3. Ensure the connection is secure but do not overtighten.

5.3. Konnessjoni tal-Enerġija

Connect the appropriate power supply to the converter. Refer to the device labeling for specific voltage and current requirements. Ensure the power source is stable and matches the device's specifications.

5.4. Kalibrazzjoni Inizjali

Before first use, or after prolonged storage, the pH converter and electrode system must be calibrated. Refer to your pH electrode's manual for specific calibration buffer requirements.

  1. Ixgħel l-apparat.
  2. Access the calibration menu using the SET button. (Specific steps may vary, consult the device's on-screen prompts or a more detailed technical manual if available).
  3. Follow the on-screen instructions to perform a 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01).
  4. Rinse the electrode thoroughly with distilled water between buffer solutions.
  5. Confirm calibration settings.

6. Joperaw

6.1. Tieħu Kejl

  1. Ensure the pH electrode is properly connected and calibrated.
  2. Immerse the pH electrode into the sample solution, ensuring the sensing bulb and reference junction are fully submerged.
  3. Allow sufficient time for the reading to stabilize on the digital display. The display will show the current pH value.
  4. Note any temperature readings if the electrode has an integrated temperature sensor and ATC (Automatic Temperature Compensation) is active.

6.2. Navigazzjoni fil-menu

The SET, ▼, and ▲ buttons are used to navigate through the device's menu options. Press SET to enter the menu or confirm a selection. Use ▼ and ▲ to scroll through options or adjust values.

  • SETT (1): Enter/Exit menu, confirm selection.
  • ▼ (2): Scroll down, decrease value.
  • ▲ (3): Scroll up, increase value.

Specific menu functions (e.g., setting alarm limits, output configuration) will be detailed in a more advanced technical manual or on-screen prompts.

7. Manutenzjoni

7.1. Cleaning the Converter

Wipe the exterior of the converter with a soft, damp drapp. Tużax prodotti tat-tindif jew solventi li joborxu. Kun żgur li l-ebda likwidu ma jidħol fl-apparat.

7.2. Manutenzjoni ta 'l-elettrodu tal-pH

Proper maintenance of the pH electrode is crucial for accurate readings and extended lifespan. Refer to your specific pH electrode's instruction manual for detailed care instructions. General guidelines include:

  • Always keep the electrode's sensing bulb hydrated, typically in a storage solution or pH 7 buffer. Never store dry.
  • Rinse the electrode with distilled or deionized water after each measurement.
  • Clean the electrode regularly to remove sample residues. Specific cleaning solutions may be required depending on the application.
  • Recalibrate the electrode regularly, especially if readings become unstable or inaccurate.

7.3. Ħażna

When not in use for extended periods, store the converter in a clean, dry environment at room temperature. Ensure the pH electrode is properly stored according to its manufacturer's recommendations.

8 Issolvi l-problemi

Problema Kawża Possibbli Soluzzjoni
L-ebda display/l-apparat mhux qed jixgħel No power, faulty power supply, incorrect connection. Check power cable and source. Ensure correct voltage.
Unstable or inaccurate pH readings Electrode not calibrated, dirty electrode, damaged electrode, air bubbles, incorrect temperature compensation. Recalibrate electrode. Clean electrode. Replace electrode if damaged. Ensure electrode is fully submerged. Check ATC settings.
Messaġġ ta' "Żball" fuq il-wiri Electrode fault, out of range measurement, internal device error. Check electrode connection. Try another electrode if available. Refer to specific error codes in a detailed technical manual. Contact support if persistent.
Ħin ta 'rispons bil-mod Aged or dirty electrode, low sample temperatura. Clean or recondition electrode. Allow electrode to equilibrate with sample temperature. Consider replacing electrode.

If the problem persists after attempting these solutions, please contact Greisinger customer support or your local distributor.

9. Speċifikazzjonijiet

Karatteristika Dettall
Manifattur GREISINGER
Numru tal-Mudell tal-Oġġett 602331
Dimensjonijiet tal-Prodott (L x W x H) 5.5 x 8.2 x 8 ċm; 9.07 gramma
ASIN B00ICKLET6
Kwantità ta' oġġetti 1
Battery(ies) included Nru
Batterija(i) meħtieġa Nru
Date first available on Amazon.com.be 12 ta’ Awwissu 2022
Discontinued by manufacturer Nru
Disponibilità ta 'spare parts Informazzjoni mhux disponibbli dwar il-partijiet ta' riżerva

10. Garanzija u Appoġġ

Greisinger products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Greisinger websit.

For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts and service, please contact your authorized Greisinger dealer or the manufacturer directly. Contact information can typically be found on the product packaging or the official Greisinger websit.

Dokumenti Relatati - GPHU 014 MP/BNC

Preview Manwal tat-Tħaddim GREISINGER GE xxx: Elettrodi tal-pH
Manwal komprensiv tat-tħaddim għall-elettrodi tal-pH tas-serje GREISINGER GE xxx, li jkopri s-sigurtà, il-bażiċi, il-kejl, il-kalibrazzjoni, il-manutenzjoni, l-għażla, u l-ispeċifikazzjonijiet. Jinkludi gwida dettaljata għal kejl preċiż tal-pH.
Preview GREISINGER GIA 20 EB / PK Manual: Connection and Operation
This manual provides comprehensive instructions for the GREISINGER GIA 20 EB / PK microprocessor-controlled displaying, monitoring, and controlling device. It covers safety regulations, electrical connections for various input signals and output types, device configuration using software, switchpoint and alarm settings, offset/slope adjustment, serial interface, error codes, specifications, and disposal notes.
Preview GREISINGER GMH 3710 Precision Thermometer Operating Manual
This operating manual provides detailed instructions for the GREISINGER GMH 3710 precision thermometer. It covers intended use, safety precautions, product specifications, handling, configuration, output options, input adjustments, probe connections, basic temperature measurement principles, fault messages, and disposal guidelines for Pt100 temperature sensors.
Preview Greisinger GDH 200 Series Manometers and Barometers: Technical Overview
Discover the Greisinger GDH 200 series handheld pressure measurement instruments. This document details the GDH 200-07 fine manometer, GDH 200-13 manometer, and GDH 200-14 vacuum/barometer, highlighting their specifications and features for professional use.
Preview Manwal tat-Tħaddim tal-Miter tal-Umdità GREISINGER GMH 38-LW1 / -LW2 Appendiċi
Appendiċi tal-manwal tat-tħaddim għas-sett tal-kejl tal-umdità GREISINGER GMH 38-LW1 / -LW2 għal applikazzjonijiet agrikoli. Ikopri l-użu maħsub, is-sigurtà, id-deskrizzjoni tal-prodott, l-immaniġġjar, il-prinċipji tal-kejl, u l-ispeċifikazzjonijiet għal laqx tal-injam, qmuħ, ħuxlief, u tiben.
Preview Manwal tat-Tħaddim tal-Monitor Kompatt tas-CO2 G 1910-02 b'Allarm
Manwal tat-tħaddim għall-G 1910-02 Compact CO2 Monitor b'Allarm, li jiddeskrivi l-karatteristiċi tiegħu, l-istruzzjonijiet tas-sigurtà, it-tħaddim, il-manutenzjoni, u l-ispeċifikazzjonijiet tekniċi.