1. Introduzzjoni
This manual provides essential information for the proper installation, operation, and maintenance of the Nordyne 913874 4-Pole Single Circuit Adapter. This component is specifically designed for use with mobile home and manufactured home electric furnaces, facilitating the conversion of a dual circuit system to a single circuit system.
2. Informazzjoni dwar is-Sigurtà
TWISSIJA: Electrical work can be hazardous. Always disconnect power at the main circuit breaker before attempting any installation, maintenance, or repair. Failure to do so may result in serious injury or death. Installation should only be performed by a qualified technician in accordance with all local and national electrical codes.

Image: The Nordyne 913874 4-Pole Single Circuit Adapter, showing its main body and the attached warning label with installation instructions.
CAUTION 240 VAC. 100 AMP MAX. INSTALL TERMINAL COVER BEFORE ENERGIZING LINE TERMINALS. JUMPER BAR ASSEMBLY CAT. NO. QKX4200-JBAF. USE ONLY SQUARE D SERIES 3 TYPE. ALL CONNECTORS OF JUMPER BAR ASSEMBLY MUST BE FILLED WITH CIRCUIT BREAKERS BEFORE ENERGIZING. JUMPER BAR ASSY MUST BE INSTALLED TO FIT TIGHT AGAINST CONDUIT BREAKER. DO NOT EXCEED MAXIMUM CIRCUIT. TERMINAL LINE TERMINAL MAX RANGE TORQUE.
Ensure all connections are secure and properly insulated. Verify that the furnace is compatible with a single circuit system after adapter installation.
3. Setup u Installazzjoni
The Nordyne 913874 adapter is designed to convert a dual circuit furnace system to a single circuit system. Follow these general steps for installation. Always refer to your furnace's specific wiring diagram and local electrical codes.
- Skonnettjar tal-Enerġija: Itfi l-enerġija kollha lill-forn fil-pannell elettriku prinċipali. Ikkonferma li l-enerġija hija mitfija billi tuża voltagtester.
- Kompartiment tal-Forn tal-Aċċess: Open the furnace access panel to locate the existing wiring and circuit board.
- Identify Circuits: Carefully identify the dual circuit wiring that needs to be converted.
- Install Adapter: Mount the 913874 adapter securely within the furnace compartment. Connect the furnace wiring to the adapter terminals as per the instructions on the adapter's label and your furnace's wiring diagram. Ensure the jumper bar assembly (if applicable, Cat. No. QKX4200-JBAF) is correctly installed and all connectors are filled with circuit breakers before energizing.
- Konnessjonijiet sikuri: Ensure all electrical connections are tight and properly torqued according to the specifications provided on the adapter label (if available, e.g., 'MAX RANGE TORQUE').
- Kompartiment Magħluq: Ibdel il-pannell tal-aċċess tal-forn.
- Irrestawra l-Enerġija: Restore power to the furnace at the main electrical panel.
- Operazzjoni tat-Test: Verify the furnace operates correctly on the single circuit system.
4. Operazzjoni
The 913874 adapter is a passive electrical component. Once correctly installed, it facilitates the electrical conversion from a dual circuit to a single circuit system for your furnace. Its operation is integrated into the furnace's overall electrical system, requiring no direct user interaction after installation. The furnace will operate as designed on the newly configured single circuit.
5. Manutenzjoni
The Nordyne 913874 adapter is designed for long-term reliability and typically requires no routine maintenance. However, it is recommended to:
- Periodically inspect electrical connections for tightness and signs of corrosion during routine furnace maintenance.
- Ensure the area around the adapter remains free from dust and debris to prevent overheating.
- If any issues arise with the furnace's electrical system, consult a qualified HVAC technician.
6 Issolvi l-problemi
If the furnace fails to operate correctly after the adapter installation, consider the following:
- Ebda Qawwa għall-Forn: Check the main circuit breaker for the furnace. Ensure it is in the 'ON' position. Verify all connections to the adapter are secure.
- Wiring Skorrett: Double-check all wiring connections against the furnace's wiring diagram and the adapter's instructions. Incorrect wiring is a common cause of malfunction.
- Konnessjonijiet sfużi: Ensure all terminal screws are tightened to the specified torque. Loose connections can cause intermittent operation or arcing.
- Ħsara tal-Komponent: While rare, if all other troubleshooting steps fail, the adapter itself may be faulty. In such cases, professional diagnosis is recommended.
For complex issues, always contact a certified HVAC technician.
7. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Numru tal-Mudell | 913874 |
| Manifattur | Nordyne |
| Piż tal-oġġett | 7 uqija |
| Dimensjonijiet tal-Prodott | 6 x 6 x 6 pulzieri |
| Kwantità tal-Pakkett tal-Oġġett | 1 |
| VoltagKlassifikazzjoni e | 240 VAC (as per label) |
| Klassifikazzjoni kurrenti | 100 AMP MAX (as per label) |
| L-Ewwel Data Disponibbli | 10 ta’ Ottubru, 2013 |
8. Garanzija u Appoġġ
Specific warranty information for the Nordyne 913874 adapter is typically provided by the point of purchase or the original equipment manufacturer (Nordyne). Please retain your proof of purchase for any warranty claims.
For technical support or inquiries regarding this product, please contact your authorized Nordyne dealer or a qualified HVAC professional.