FLIR MR77

Manwal tal-Utent tal-Miter tal-Umdità mingħajr Pinnijiet FLIR MR77

Comprehensive instructions for operation and maintenance of your FLIR MR77 Moisture Meter.

1. Introduzzjoni

The FLIR MR77 Pinless Moisture Meter is a professional-grade instrument designed for accurate moisture and environmental measurements. This device combines pinless moisture detection with an external pin probe, relative humidity, and temperature sensing capabilities, making it a versatile tool for various applications.

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your FLIR MR77 meter to ensure optimal performance and longevity.

2. Żpakkjar u Kontenut

Carefully unpack all items from the packaging. Verify that all components are present and undamaged. If any items are missing or damaged, contact your supplier immediately.

Kontenut tal-Pakkett:

FLIR MR77 Pinless Moisture Meter

Figure 2.1: The FLIR MR77 Pinless Moisture Meter with its integrated sensor and display.

3. Konfigurazzjoni u Installazzjoni tal-Batterija

3.1 Installazzjoni tal-batterija

  1. Sib il-kompartiment tal-batterija fuq wara tal-miter.
  2. Iftaħ l-għatu tal-kompartiment tal-batterija.
  3. Insert the included 9V battery, observing correct polarity.
  4. Agħlaq l-għatu tal-kompartiment tal-batterija sew.

3.2 Attaching Sensors

The MR77 comes with an integrated pinless sensor and ports for external sensors.

External Temperature and Relative Humidity Sensor

Figure 3.1: The external temperature and relative humidity sensor (MR01).

Pin Probe and Cable

Figure 3.2: The pin probe (MR02) for penetrating moisture measurements.

4. Istruzzjonijiet Operattivi

4.1 Tixgħel/Jitfi

Agħfas il- Qawwa button (usually located at the bottom of the device) to turn the meter on or off.

4.2 Display Overview

Close-up of FLIR MR77 display showing moisture and temperature readings

Figure 4.1: Close-up of the MR77 display showing various readings.

The backlit LCD displays moisture readings, relative humidity, air temperature, dew point, and other relevant data. Icons indicate measurement mode, battery status, and other functions.

4.3 Modi ta' Kejl

The FLIR MR77 offers multiple measurement capabilities:

Hand holding FLIR MR77 performing a pinless moisture measurement

Figure 4.2: Performing a pinless moisture measurement with the FLIR MR77.

Hand holding FLIR MR77 using the integrated IR thermometer with laser pointer

Figure 4.3: Using the integrated IR thermometer with laser targeting.

4.4 Material Group Selection

The MR77 allows selection of different material groups for more accurate moisture readings. Refer to the "Material Group Reference" table in the Specifications section for details on specific materials.

FLIR MR77 display showing material group and relative humidity

Figure 4.4: The display indicating the selected material group (M09) and Relative Humidity (RH).

4.5 Ħażna u Rakkonti tad-Data

Uża l- AĦŻEN/SEJĦAR button to save and retrieve measurement data. Consult the full user manual for detailed instructions on data logging and management.

4.6 Meter Link Smartphone App

The FLIR MR77 can connect to a smartphone app via Bluetooth for enhanced data monitoring, comparison, and reporting. Download the Meter Link app from your device's app store.

Screenshots of the FLIR Meter Link smartphone app showing data logging and comparison features

Figure 4.5: The Meter Link smartphone app interface for data monitoring and comparison.

5. Manutenzjoni

5.1 Tindif

Imsaħ il-barra tal-miter b'reklamaramp cloth. Do not use abrasive cleaners or solvents. Keep the sensor areas clean and free of debris.

5.2 Sostituzzjoni tas-Sensor

The temperature/relative humidity sensor (MR01) is field-replaceable. If readings become inaccurate or the sensor is damaged, replace it with an authorized FLIR replacement part. Refer to the full user manual for detailed replacement instructions.

5.3 Ħażna

Store the FLIR MR77 in a cool, dry place when not in use. Remove the battery if storing for extended periods to prevent leakage.

6 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Il-miter ma jixgħelx.Batterija mejta jew installata ħażin.Check battery polarity, replace battery.
Inaccurate moisture readings.Incorrect material group selected; sensor dirty or damaged; external interference.Verify material group; clean or replace sensor; move away from strong electromagnetic fields.
Inaccurate RH/Temperature readings.Sensor maħmuġ jew bil-ħsara.Clean or replace the MR01 sensor.
Kwistjonijiet ta' konnettività Bluetooth.Meter not in pairing mode; app issues; distance from device.Ensure meter Bluetooth is active; restart app/meter; reduce distance.

For further assistance, refer to the official FLIR MR77 User Manual (PDF) or contact FLIR customer support.

7. Speċifikazzjonijiet

Speċifikazzjonijiet Ġenerali:

Speċifikazzjonijiet tal-Kejl:

FLIR MR77 Specifications including moisture and environmental measurements

Figure 7.1: Detailed specifications for the FLIR MR77.

Material Group Reference:

Table of Material Group Reference for FLIR MR77

Figure 7.2: Reference table for selecting appropriate material groups for moisture measurements.

This table provides common names of timbers and other materials, along with their corresponding material group numbers (e.g., Group 1-8 for timbers, Group 9 for plywood, drywall, and oriented strand board, Group 10 for brick, cement screed, and concrete, Group 11 for cement mortar, anhydrite screed, lime mortar, and plaster). Groups 10 and 11 are not specified for accuracy and should be used for reference only.

8. Informazzjoni dwar Garanzija

The FLIR MR77 Pinless Moisture Meter is covered by a Garanzija Limitata tul il-Ħajja. For specific terms and conditions, including details on coverage and how to make a warranty claim, please refer to the official warranty documentation provided with your product or visit the FLIR websit.

9. Appoġġ u Riżorsi Addizzjonali

For further information, technical support, or to access the complete user manual, please use the resources below:

Dokumenti Relatati - MR77

Preview Manwal tal-Utent FLIR MR77: Psikrometru tal-Umdità mingħajr Pinnijiet b'Termometru IR u Bluetooth
Manwal tal-utent għall-FLIR MR77, psikrometru tal-umdità mingħajr pinnijiet li jinkludi termometru infra-aħmar u konnettività Bluetooth METERLiNK. Tgħallem dwar il-karatteristiċi, l-operat u l-ispeċifikazzjonijiet tiegħu.
Preview FLIR MR77 User's Manual: Pinless Moisture Psychrometer with IR Thermometer
User's manual for the FLIR MR77, a pinless moisture psychrometer featuring an infrared thermometer and Bluetooth METERLiNK connectivity. Learn about its features, operation, and technical specifications.
Preview Gwida għall-Bidu Mgħaġġel tal-Miter tal-Umdità bil-Sonda tal-Ballun FLIR MR59
Gwida ta' bidu rapidu għall-FLIR MR59 Ball Probe Moisture Meter bil-Bluetooth, li tkopri s-setup, it-tħaddim, id-deskrizzjoni tal-miter, il-buttuni tal-funzjoni, l-indikaturi tal-wiri, u l-konnettività Bluetooth.
Preview FLIR MR176 Imaging Moisture Meter Plus with IGM User Manual
User manual for the FLIR MR176 Imaging Moisture Meter Plus, detailing its features, operation, maintenance, and specifications. Learn how to use its thermal imaging, pinless, and pin probe moisture measurement capabilities.
Preview Kit tal-Aċċessorji FLIR E60: Lista Komprensiva ta' Aċċessorji tal-Kamera Termali
Lista dettaljata ta' aċċessorji għall-kamera tal-immaġini termali FLIR E60, inklużi kaxxi, kejbils, provvisti tal-enerġija, ċarġers, batteriji, memory cards, u dokumentazzjoni minn Advanced Test Equipment Corp.
Preview Skeda ta' dejta tal-Kamera Termali FLIR iXX tas-Serje Attivata bl-App b'LTE
Speċifikazzjonijiet u karatteristiċi dettaljati għall-FLIR iXX-Series App-Enabled Thermal Camera b'LTE, inkluż riżoluzzjoni IR, sensittività, FOV, applikazzjonijiet, u dejta fiżika.