Hager 5100 Series

Hager 5100 Series Heavy Duty Surface Door Closer Instruction Manual

Mudell: Serje 5100

Prodott Overview

The Hager 5100 Series Grade 1 door closer is engineered for heavy-duty applications in high-traffic and demanding environments such as schools and hospitals. Constructed from durable cast iron, this surface door closer is designed for longevity and reliable performance. It features a multi-mount design and a non-handed configuration for versatile installation. Key functionalities include an adjustable spring size (1-6) and a delayed action closing feature, allowing for controlled door closure between 90° and 70° over a minimum of 20 seconds, which can be further adjusted. The closer also incorporates a hold-open arm for convenience.

Karatteristiċi ewlenin:

Hager 5100 Series door closer in sprayed aluminum finish with hold-open arm.

This image displays the Hager 5100 Series heavy-duty surface door closer. It features a rectangular main body in a sprayed aluminum finish, with an adjustable arm mechanism extending from the top. The arm includes a hold-open function, and the overall construction is designed for robust performance.

Setup u Installazzjoni

The Hager 5100 Series door closer is designed for multi-mount applications and is non-handed, simplifying the installation process for various door types and orientations. Installation typically involves mounting the closer body and arm assembly to the door and frame using screws.

Passi Ġenerali ta' Installazzjoni:

  1. Preparazzjoni: Ensure the door and frame are structurally sound and clear of obstructions. Identify the desired mounting position (e.g., parallel arm, regular arm, top jamb).
  2. Mounting the Closer Body: Secure the closer body to the door or frame using appropriate fasteners. Refer to the specific mounting template provided with your unit for precise hole placement.
  3. Attaching the Arm Assembly: Connect the main arm to the closer spindle and the forearm to the door frame or door, depending on the mounting type. Ensure all connections are secure.
  4. Aġġustament Inizjali: After installation, perform initial adjustments for closing speed and latching speed.

Nota: Always consult the detailed installation template and instructions included with your specific Hager 5100 Series unit for precise measurements, drilling patterns, and mounting configurations. Professional installation is recommended for optimal performance and safety.

Tħaddim u Aġġustamenti

The Hager 5100 Series door closer offers several adjustable features to customize door operation according to specific requirements.

Spring Power Adjustment:

Delayed Action Feature:

Hold-Open Arm:

Attenzjoni: Over-adjusting or forcing adjustment valves can damage the closer. Make small adjustments and test the door's operation after each change. If unsure, consult a qualified technician.

Manutenzjoni

Regular maintenance ensures the longevity and optimal performance of your Hager 5100 Series door closer.

If any components appear damaged or excessively worn, contact Hager support or a qualified technician for replacement parts or service.

Issolvi l-problemi

This section addresses common issues you might encounter with your Hager 5100 Series door closer.

ProblemaKawża PossibbliSoluzzjoni
Door closes too fast or too slow.Improper adjustment of closing or latching speed valves.Refer to the 'Operating and Adjustments' section to fine-tune the closing and latching speed valves. Make small adjustments.
Bieb ma jagħlaqx kompletament.Insufficient spring power; Latching speed too slow; Obstruction; Misaligned door/frame.Increase spring power (refer to 'Operating and Adjustments'). Increase latching speed. Check for physical obstructions. Inspect door and frame for proper alignment.
Il-bieb jingħalaq b'daqqa ta' ħarta.Closing or latching speed too fast; Excessive spring power.Decrease closing and latching speeds. Reduce spring power if necessary.
Oil leakage from closer body.Siġilli jew komponenti interni bil-ħsara.This indicates a serious issue. The closer requires professional service or replacement. Contact Hager support immediately.
Hold-open function not engaging/disengaging.Arm assembly issue; Adjustment screw loose/tight.Inspect the hold-open mechanism on the arm. Adjust or tighten the relevant screw as per the arm's design.

For issues not listed here or if troubleshooting steps do not resolve the problem, please contact Hager customer support.

Speċifikazzjonijiet

Numru tal-Mudell126475
BrandHager
Serje5100 Serje
MaterjalĦadid fondut
GradGrade 1 (Heavy Duty)
TemmSprayed Aluminum
Daqs tar-RebbiegħaAġġustabbli 1-6
Tip ta 'ImmuntarMulti-Mount, Surface
KonsenjaMhux Mogħti
ĊertifikazzjonijietBHMA Certified ANSI A156.4, UL/cUL Listed (up to 3 hours)
Dimensjonijiet tal-ProdottMadwar 15.5 x 8 x 3 pulzieri
Użi RakkomandatiHigh-traffic areas, schools, hospitals
UPC798550264750

Informazzjoni dwar Garanzija

The Hager 5100 Series door closer is backed by a Garanzija tul il-ħajja. This warranty covers defects in materials and workmanship under normal use and service. For specific terms, conditions, and claim procedures, please refer to the official warranty documentation provided with your product or visit the Hager Companies websit.

Appoġġ għall-Klijent

Should you require assistance with installation, operation, maintenance, or troubleshooting, please contact Hager Companies customer support.

Meta tikkuntattja l-appoġġ, jekk jogħġbok żomm in-numru tal-mudell tal-prodott tiegħek (126475) u kwalunkwe informazzjoni rilevanti dwar ix-xiri lesti.

Dokumenti Relatati - 5100 Serje

Preview Istruzzjonijiet għall-Installazzjoni tal-Apparat tal-Ħruġ ta' Virga Vertikali tal-Wiċċ Hager Serje 4500
Gwida dettaljata għall-installazzjoni għall-Apparat tal-Ħruġ minn Virga Vertikali tal-Wiċċ Hager 4500 Series, inklużi l-mudelli 4500S, 4500SF, 4500L, u 4500LF. Tkopri partijiet, għodda, u assemblaġġ pass pass għal installazzjoni professjonali.
Preview Istruzzjonijiet tal-Immuntar ta' Hager univers N għal U96N/UG31N1 u U97N
Gwida dettaljata għall-installazzjoni għas-sistema ta' għeluq elettriku univers N ta' Hager, li tkopri l-mudelli U96N/UG31N1 u U97N. Tipprovdi struzzjonijiet pass pass, għodda meħtieġa, speċifikazzjonijiet tat-torque, u twissijiet ta' sigurtà għal immuntar u assemblaġġ xieraq.
Preview Istruzzjonijiet għall-Immuntar ta' Hager UC52LAX1x għal Enclosures Elettriċi
Istruzzjonijiet dettaljati għall-immuntar u gwida għas-serje Hager UC52LAX1x, inklużi UC52LAX12 u UC52LAX13, għall-installazzjoni ta' komponenti elettriċi f'enclosures.
Preview Manwal ta' Installazzjoni Bażika/Esperta ta' Hager TJA670/TJA470 domovea
Dan id-dokument jipprovdi gwida komprensiva għall-installazzjoni u l-konfigurazzjoni tas-sistemi Hager TJA670 domovea Basic u TJA470 domovea Expert. Ikopri s-sistema fuqview, installazzjoni tas-softwer, setup inizjali, ġestjoni tal-proġett, funzjonijiet disponibbli, dettalji tal-apparat, u integrazzjoni ma' servizzi esterni.
Preview Istruzzjonijiet għall-Immuntar tal-Bord tad-Distribuzzjoni Hager Volta
Istruzzjonijiet komprensivi għall-immuntar għal bordijiet tad-distribuzzjoni elettrika tas-serje Hager Volta mmuntati fuq wiċċ l-ilma u mmuntati fil-wiċċ, li jiddettaljaw il-passi tal-installazzjoni, l-assemblaġġ tal-komponenti, u l-konformità mal-istandards IEC/EN.
Preview Manwal tal-Installazzjoni u l-Istruzzjonijiet tas-Swiċċ tal-Ħin ta' Kuljum Hager EHN010/EHN011
Gwida komprensiva għall-installazzjoni u t-tħaddim tas-swiċċijiet tal-ħin ta' kuljum Hager EHN010 u EHN011. Tinkludi speċifikazzjonijiet tekniċi, struzzjonijiet ta' sigurtà, u linji gwida dwar l-użu.