1. Introduzzjoni u Fuqview
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Jandy 7790 Temperature Sensor. This sensor is designed for accurate temperature monitoring in water, air, or solar applications within pool and spa automation systems. Proper installation and maintenance are crucial for optimal performance and longevity.

Figure 1: Jandy 7790 Temperature Sensor with coiled cable, showing the sensor probe and two-wire connection.
Vidjo 1: Fuqview of the 520272 Air/Water/Solar Temperature Sensor, highlighting its features and applications.
2. Informazzjoni dwar is-Sigurtà
Always prioritize safety during installation and maintenance. Failure to follow these guidelines may result in personal injury, equipment damage, or voiding the warranty.
- Skonnettja l-Enerġija: Before performing any installation or maintenance, ensure all power to the pool/spa control system and associated equipment is completely disconnected at the main circuit breaker.
- Persunal kwalifikat: Installation and servicing should only be performed by qualified and experienced professionals familiar with pool/spa electrical systems and plumbing.
- Sigurtà tal-Ilma: Ensure no water leaks occur after installation. Check all connections for tightness.
- Kompatibilità tal-komponenti: Use only genuine Jandy replacement parts or approved equivalents to ensure proper function and safety.
3. Kontenut tal-Pakkett
Ivverifika li l-komponenti kollha huma preżenti u mhux imħassra malli tiftaħ il-pakkett:
- Jandy 7790 Temperature Sensor with integrated cable.

Figure 2: Jandy 7790 Temperature Sensor shown in its retail packaging, displaying the sensor and coiled cable.
4. Setup u Installazzjoni
This section outlines the general procedure for replacing the Jandy 7790 Temperature Sensor. Specific steps may vary based on your existing pool/spa control system configuration. Refer to your system's main manual for detailed wiring diagrams.
4.1. Preparazzjoni
- Itfi l-Enerġija: Locate the main circuit breaker for your pool/spa equipment and turn off all power. Verify that the system is completely de-energized.
- Identifika l-Post tas-Sensor: The temperature sensor is typically installed in a dedicated port on the plumbing near the heater, or in an air/solar collector.
4.2. Sostituzzjoni tas-Sensor
- Neħħi s-Sensor il-Qadim: Carefully loosen any retaining nuts or clamps securing the old sensor. Gently pull the sensor out of its housing. Be prepared for a small amount of water to escape if replacing a water sensor.
- Skonnettja l-Wiring: Open the control panel of your pool/spa system. Locate the terminals where the old sensor's wires are connected (typically labeled 'WATER', 'AIR', or 'SOLAR' SENSOR). Note the wire connections (e.g., red to one terminal, white to another) and disconnect them.
- Ipprepara Sensor Ġdid: Apply a small amount of O-ring lubricant (silicone-based) to the O-ring of the new Jandy 7790 sensor. This aids in installation and ensures a proper seal.
- Installa Sensor Ġdid: Insert the new sensor into the designated port. Secure it with the retaining nut or clamp, ensuring a snug fit without overtightening.
- Wajer tar-Rotta: Carefully route the new sensor's cable into the control panel, following existing wiring paths to maintain a neat and secure installation.
- Qabbad il-Wiring: Connect the new sensor's wires to the appropriate terminals in the control panel, matching the connections of the old sensor. Ensure wires are securely fastened.
- Agħlaq il-Panel tal-Kontroll: Securely close the control panel cover.
4.3. Wara l-Installazzjoni
- Irrestawra l-Enerġija: Turn on the main circuit breaker to restore power to the pool/spa system.
- Ivverifika l-Operazzjoni: Check the control panel display for accurate temperature readings. Monitor the system for any error codes or unusual behavior.
Video 2: Detailed guide on how to replace a 520272 Air/Water/Solar Temperature Sensor, demonstrating the steps involved in disconnecting the old sensor and installing the new one.
5. Istruzzjonijiet Operattivi
The Jandy 7790 Temperature Sensor operates in conjunction with your existing pool/spa automation system. It provides temperature data to the control unit, which then manages heating, cooling, or solar functions based on programmed settings.
- The sensor itself does not have user-adjustable settings.
- All temperature set points, modes (e.g., pool heat, spa heat, solar priority), and scheduling are managed through your pool/spa control panel.
- Refer to your specific pool/spa automation system's user manual for detailed operating instructions and programming guides.
6. Manutenzjoni
Regular maintenance helps ensure the accuracy and longevity of your temperature sensor.
- Spezzjoni Viżwali: Periodically inspect the sensor and its cable for any signs of physical damage, corrosion, or wear.
- Indafa: Ensure the sensor probe is free from debris, scale buildup, or algae, especially if installed in water. Gently clean with a soft brush if necessary.
- Kundizzjoni taċ-Ċirku-O: If the sensor is removed for any reason, inspect the O-ring for cracks or deterioration. Replace if damaged and apply fresh O-ring lubricant upon reinstallation.
- Integrità tal-Cable: Check the cable for cuts, abrasions, or exposed wiring. Repair or replace if damage is found.
7 Issolvi l-problemi
If you experience issues with temperature readings or system operation, consider the following troubleshooting steps:
- Qari tat-Temperatura Mhux Korrett:
- Verify the sensor is properly seated and sealed.
- Check for debris or scale buildup on the sensor probe.
- Ensure wiring connections at the control panel are secure.
- Consult your pool/spa control system manual for sensor calibration procedures, if available.
- No Temperature Reading / Error Code:
- Confirm power is supplied to the control system.
- Inspect the sensor cable for any breaks or disconnections.
- Check the wiring connections at the control panel for proper seating and tightness.
- If the issue persists, the sensor may be faulty and require replacement.
- System Not Responding to Temperature:
- Ensure the pool/spa control system is set to the correct operating mode (e.g., heating enabled).
- Verify that the temperature set point is above the current temperature for heating to activate.
- Consult your pool/spa control system manual for programming and operational details.
If troubleshooting steps do not resolve the issue, contact a qualified pool/spa technician for further assistance.
8. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Brand | Jandy |
| Numru tal-Mudell | 7790 |
| Użi Speċifiċi | Water, Air, Solar Temperature Sensing |
| Tip ta 'Immuntar | Flanġ Mount |
| Dimensjonijiet tal-oġġett (L x W x H) | 4 x 2 x 2 pulzieri |
| Piż tal-oġġett | 3.99 uqija |
| UPC | 610074776178 |

Figura 3: Close-up view of the Jandy 7790 Temperature Sensor probe, illustrating its design for accurate temperature detection.
Video 3: Explanation of overmolding technology in temperature sensors, detailing how it provides protection against physical damage, moisture, and contaminants, enhancing durability in harsh environments.
9. Garanzija u Appoġġ
For warranty information, technical support, or to purchase replacement parts, please contact Jandy customer service or your authorized Jandy dealer. Keep your purchase receipt as proof of purchase.