Apeks AP0334F-1

Apeks XTX 200 Din Scuba Diving Regulator User Manual

Model: AP0334F-1

Prodott Overview

The Apeks XTX 200 is a high-performance scuba diving regulator, designed for reliability and ease of use in various diving conditions. It features a robust first stage and a versatile second stage, offering exceptional breathing characteristics.

Apeks XTX 200 Din Scuba Diving Regulator complete system

Figure 1: Complete Apeks XTX 200 Din Scuba Diving Regulator system, showing the first stage, it-tieni stage, and hoses.

Karatteristiċi Ewlenin

  • Flagship of the Apeks regulator range, ensuring top-tier performance.
  • Utilizes the proven FSR type first stage, known for its reliability and consistent air delivery.
  • Features a bright chrome finish for enhanced durability and aesthetic appeal.
  • All medium pressure ports are 3/8”, allowing the reversible XTX second stage to be mounted on either side of the first stage.
  • Over-balancing feature increases medium pressure air in the hose faster than ambient pressure, leading to superior performance at depth.
  • Comes standard with an environmental dry kit, protecting against water and contaminants and improving coldwater resistance.
  • Compatible with EAN 40 (Nitrox) directly out of the box.
  • It-tieni stage can be reversed from right-hand to left-hand configuration by an Authorized Apeks Technician.
  • Diver Changeable Exhaust (DCE) System allows switching between a large exhaust tee for optimal bubble dispersion and a smaller, more compact tee.
  • Improved exhalation performance and overall work of breathing.
  • Pneumatically balanced second stage with diver-adjustable controls for opening effort and venturi control.
  • Suitable for coldwater use.

Setup

Proper setup of your Apeks XTX 200 regulator is crucial for safe and efficient diving. Always ensure all components are clean and free of debris before assembly.

1. L-ewwel Stage Konnessjoni

L-ewwel stage connects directly to your scuba cylinder valve. Ensure the O-ring on the first stage is in good condition and properly seated. For DIN connections, screw the first stage directly into the cylinder valve until hand-tight. Do not overtighten.

Apeks XTX 200 First Stage Regolatur

Figure 2: The Apeks XTX 200 First Stage Regulator, which connects to the cylinder valve.

2. It-tieni Stage and Hose Connections

Connect the primary second stage hose to a medium pressure port on the first stage. Connect the alternate air source (octopus) hose to another medium pressure port. Ensure all hose connections are securely tightened using an appropriate wrench, but avoid excessive force. The XTX 200 features 3/8” medium pressure ports for flexible hose routing.

Apeks XTX 200 Second Stage Regolatur

Figure 3: The Apeks XTX 200 Second Stage Regulator, featuring adjustable controls.

3. Pressure Gauge and Inflator Hose

Attach your submersible pressure gauge (SPG) to a high pressure port on the first stage. Connect the BCD inflator hose to a dedicated low pressure port. Verify all connections are tight and secure.

Istruzzjonijiet Operattivi

Before each dive, perform a pre-dive check to ensure your regulator is functioning correctly.

1. Pre-Dive Check

  1. Spezzjoni Viżwali: Check all hoses for kinks, cracks, or damage. Inspect mouthpieces for tears.
  2. O-rings: Ensure the cylinder valve O-ring is present and in good condition.
  3. Provvista tal-Ajru: Slowly open the cylinder valve fully. Listen for any air leaks.
  4. Gejġ tal-Pressjoni: Confirm the SPG reads the correct cylinder pressure.
  5. Breathing Test: Take a few breaths from both the primary and alternate second stages. Ensure smooth, easy inhalation and exhalation.
  6. Buttuna tat-tindif: Press the purge button on both second stages to confirm air flow.
  7. BCD Inflator: Test the BCD inflator and deflator buttons.

2. Adjusting the Second Stage

The XTX 200 second stage offers diver-adjustable controls:

  • Cracking Resistance Control: Adjusts the effort required to open the valve and begin air flow. Turn clockwise for higher resistance (pre-dive mode) and counter-clockwise for lower resistance (dive mode).
  • Venturi Lever: Controls the venturi effect, which assists in air delivery. In the '+' position, it provides maximum assistance for easier breathing. In the '-' position, it reduces assistance, ideal for surface swimming or when the regulator is not in use to prevent free-flow.

Manutenzjoni

Regular maintenance is essential for the longevity and safe operation of your Apeks XTX 200 regulator.

1. Post-Dive Care

  1. Tlaħliħ: After each dive, thoroughly rinse the entire regulator in fresh, clean water. Ensure the dust cap is securely in place on the first stage before rinsing. Do not press the purge button while rinsing unless the first stage is pressurized.
  2. Tnixxif: Allow the regulator to air dry completely in a shaded, well-ventilated area. Avoid direct sunlight.
  3. Ħażna: Store your regulator in a cool, dry place, away from direct sunlight, chemicals, and extreme temperatures.

2. Manutenzjoni Perjodika

Your Apeks XTX 200 regulator requires periodic professional servicing by an Authorized Apeks Technician. This typically includes:

  • Spezzjoni Annwali: A yearly check-up to ensure all components are functioning correctly and to identify any potential issues.
  • Reviżjoni: A complete overhaul, including replacement of all O-rings and worn parts, is recommended every two years or after 100 dives, whichever comes first.

Failure to perform regular maintenance and servicing may void your warranty and compromise diver safety.

Issolvi l-problemi

This section provides solutions to common issues you might encounter with your regulator. For complex problems, always consult an Authorized Apeks Technician.

ProblemaKawża PossibbliSoluzzjoni
Free-flow (continuous air flow)Venturi lever in '+' position at surface; debris in second stage; high intermediate pressure.Switch venturi lever to '-'; purge vigorously; have serviced by technician.
Nifs iebes / Xogħol qawwi tan-nifsCracking resistance too high; venturi lever in '-' position; internal issue.Adjust cracking resistance counter-clockwise; switch venturi lever to '+'; have serviced by technician.
Air leak from first stageDamaged O-ring; loose connection; internal leak.Check/replace O-ring; tighten connection; have serviced by technician.
Air leak from second stageDamaged mouthpiece; internal issue.Inspect/replace mouthpiece; have serviced by technician.

Speċifikazzjonijiet

  • Mudell: Apeks XTX 200 Din Scuba Diving Regulator (AP0334F-1)
  • L-ewwel Stage Tip: Balanced Diaphragm, FSR type
  • It-tieni Stage Tip: Pneumatically Balanced, Diver-Adjustable
  • Portijiet: 4 Medium Pressure (3/8" UNF), 2 High Pressure (7/16" UNF)
  • Temm: Bright Chrome
  • Coldwater Use: Adattat
  • Kompatibilità man-Nitrox: Up to 40% O2 (EAN 40) out of the box
  • Piż: Madwar 3 Liri (1.36 kg)
  • Dimensjonijiet (Oġġett): 14 x 7 x 4 pulzieri (35.56 x 17.78 x 10.16 ċm)

Garanzija u Appoġġ

Apeks products are manufactured to the highest standards and are backed by a comprehensive warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Apeks websit.

For technical support, service, or to locate an Authorized Apeks Dealer or Technician, please contact Apeks customer service or visit their official websit:

  • Apeks Official Websit: www.apeksdiving.com
  • Servizz tal-Klijent: Refer to your product documentation for regional contact information.

Always ensure any servicing or repairs are carried out by an Authorized Apeks Technician to maintain product integrity and warranty validity.

Dokumenti Relatati - AP0334F-1

Preview Apeks XTX DST & UST First StagManwal tal-Manutenzjoni tar-Regolatur elettroniku
Comprehensive maintenance manual for Apeks XTX DST & UST first stage regulators, providing detailed procedures for disassembly, reassembly, testing, troubleshooting, and parts identification for authorized technicians.
Preview Manwal tas-Sid tar-Regolatur Apeks
Manwal komprensiv tas-sid għar-regolaturi tal-Apeks SCUBA, li jagħti dettalji dwar is-setup, it-tħaddim, il-manutenzjoni, il-linji gwida tas-sigurtà, u informazzjoni dwar il-garanzija għal prestazzjoni ottimali tal-għadis.
Preview Apeks XTX It-Tieni StagManwal tal-Manutenzjoni tar-Regolatur elettroniku għal Tekniċi Awtorizzati
Dan il-manwal jipprovdi proċeduri preskritti mill-fabbrika għall-manutenzjoni u t-tiswija korretti tal-Apeks XTX second s.tagFirxa ta' regolaturi e. Hija maħsuba għal tekniċi awtorizzati u tkopri ż-żarmar, l-assemblaġġ mill-ġdid, l-ittestjar, u s-soluzzjoni tal-problemi.
Preview Apeks DS, US, TEK3 & Extrair First StagManwal tal-Manutenzjoni tar-Regolatur elettroniku
Manwal komprensiv ta' manutenzjoni u tiswija għal Apeks DS, US, TEK3, u Extrair first stagRegolaturi tal-iskuba elettronika. Din il-gwida tipprovdi lit-tekniċi awtorizzati bi proċeduri dettaljati għaż-żarmar, l-assemblaġġ mill-ġdid, l-ittestjar, is-soluzzjoni tal-problemi, u l-identifikazzjoni tal-komponenti.
Preview Apeks TX It-Tieni StagManwal tal-Manutenzjoni tar-Regolatur elettroniku għal Tekniċi Awtorizzati
Manwal komprensiv ta' manutenzjoni u tiswija għal Apeks TX100, TX50, TX40, u T20 sekondi stagregolaturi elettroniċi, li jiddeskrivu fid-dettall il-proċeduri ta' żarmar, assemblaġġ mill-ġdid, ittestjar u soluzzjoni tal-problemi.
Preview Apeks Regulator Spare Parts and O-Ring Identification Chart
Comprehensive identification chart for Apeks regulators, detailing spare parts, O-rings, filters, and service kit contents for models like TX, ATX, XTX, Egress, and Flight series. Includes part numbers and descriptions for servicing.