Friedrich PDE07K3SG

Friedrich PTAC Air Conditioner User Manual

Model: PDE07K3SG

1. Introduzzjoni

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of your Friedrich Packaged Terminal Air Conditioner (PTAC), Model PDE07K3SG. Please read this manual thoroughly before operating the unit to ensure safe and efficient use.

2. Informazzjoni Importanti dwar is-Sigurtà

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons. This unit operates on 230/208V and requires a dedicated 20A power supply with a NEMA 6-20P plug configuration. Ensure proper grounding and professional installation where required.

  • Tħaddimx l-unità b'korda jew plagg bil-ħsara.
  • Do not insert fingers or foreign objects into air discharge areas.
  • Ensure the unit is properly installed in a wall sleeve before operation.
  • Skonnettja l-enerġija qabel ma tagħmel xi manutenzjoni jew tindif.
  • Irreferi l-manutenzjoni kollha lil persunal tas-servizz kwalifikat.

3. Prodott Aktarview

The Friedrich PDE07K3SG is a Packaged Terminal Air Conditioner designed for efficient cooling and heating. It features a cooling capacity of 7200/7000 BtuH and a heating capacity of 11,700/9600 BtuH, operating on 230/208V. The unit utilizes R-410A refrigerant.

Friedrich PTAC Air Conditioner unit, showing the front panel and internal components.

Figure 1: Friedrich PTAC Air Conditioner (Model PDE07K3SG) with front panel and internal chassis visible. This image illustrates the overall design of the unit.

Komponenti Inklużi:

  • Chassis
  • Front Panel
  • Istruzzjonijiet għall-Installazzjoni (irreferi għal dan il-manwal)

Note: A wall sleeve is required for installation and is not included with the unit.

4. Setup u Installazzjoni

Proper installation is crucial for the performance and longevity of your PTAC unit. It is recommended that installation be performed by a qualified technician.

4.1 Rekwiżiti ta' Qabel l-Installazzjoni

  • Kmiem tal-ħajt: A compatible wall sleeve must be securely installed in the wall opening.
  • Provvista Elettrika: Ensure a dedicated 230/208V, 20A electrical circuit is available with a NEMA 6-20P receptacle. The power cord length is 5 ft.
  • Clearance: Maintain adequate clearance around the unit for proper airflow and maintenance.

4.2 Passi ta' Installazzjoni (Sommarju)

  1. Carefully unpack the chassis and front panel.
  2. Slide the chassis into the pre-installed wall sleeve, ensuring it is level and secure.
  3. Connect the power cord to the dedicated electrical outlet.
  4. Attach the front panel to the chassis according to the detailed instructions provided with the unit.
  5. Verify all connections are secure and the unit is properly seated.

For detailed installation diagrams and safety warnings, refer to the separate installation instructions included with your unit or consult a professional installer.

5. Istruzzjonijiet Operattivi

Your Friedrich PTAC unit offers various modes for optimal comfort. Familiarize yourself with the control panel (located on the front panel) to utilize all features.

5.1 Operazzjoni Bażika

  • Power On/Off: Agħfas il-buttuna tal-enerġija biex tixgħel jew titfi l-unità.
  • Għażla tal-Modalità: Use the mode button to cycle through available modes: Cool, Heat, Fan Only.
  • Aġġustament tat-temperatura: Uża l-vleġeġ 'il fuq/'l isfel biex tissettja t-temperatura mixtieqa tiegħek.
  • Veloċità tal-fann: Adjust fan speed (Low, Medium, High, Auto) for desired airflow and noise level.

5.2 Modalità tat-tkessiħ

Select "Cool" mode for air conditioning. The unit will cool the room to your set temperature. The cooling capacity is 7200/7000 BtuH.

5.3 Modalità tat-Tisħin

Select "Heat" mode for heating. The unit will heat the room to your set temperature. The heating capacity is 11,700/9600 BtuH with a heating kW of 3.5.

5.4 Modalità Fann biss

In "Fan Only" mode, the unit circulates air without cooling or heating, useful for ventilation.

6. Manutenzjoni

Regular maintenance ensures efficient operation and extends the lifespan of your PTAC unit. Always disconnect power before performing any maintenance.

6.1 Tindif tal-Filtru tal-Arja

The air filter should be cleaned monthly, or more frequently depending on usage and air quality.

  1. Itfi l-unità u skonnettja l-enerġija.
  2. Neħħi l-pannell ta 'quddiem biex taċċessa l-filtru ta' l-arja.
  3. Neħħi l-filtru tal-arja bir-reqqa.
  4. Aħsel il-filtru b'ilma sħun u bis-sapun. Laħlaħ sew.
  5. Ħalli l-filtru jinxef kompletament qabel ma terġa' ddaħħalh.
  6. Reattach the front panel and restore power.

6.2 Tindif tal-Kojl

The evaporator and condenser coils should be inspected and cleaned annually by a qualified technician to maintain efficiency.

6.3 Tindif ta' barra

Imsaħ il-barra tal-unità b'artab, damp drapp. Tużax kimiċi ħarxa jew tindif li joborxu.

7 Issolvi l-problemi

Qabel ma tikkuntattja lis-servizz, erġa'view il-kwistjonijiet u s-soluzzjonijiet komuni li ġejjin:

ProblemaKawża PossibbliSoluzzjoni
L-unità ma tixgħel.Bla dawl, circuit breaker qata’, plagg maħlul.Check power cord connection, reset circuit breaker, ensure power outlet is functional.
Tkessiħ/tisħin insuffiċjenti.Dirty air filter, blocked airflow, incorrect mode/temperature setting, unit too small for room.Clean air filter, ensure no obstructions, verify mode and temperature settings, consult a professional for sizing.
Storbju mhux tas-soltu.Loose parts, fan obstruction, unit not level.Check for loose components, remove obstructions, ensure unit is level in the wall sleeve. If noise persists, contact service.
Tnixxija tal-ilma.Blocked condensate drain.Inspect and clear the condensate drain. If problem persists, contact service.

Jekk il-problema tippersisti wara li tipprova dawn is-soluzzjonijiet, jekk jogħġbok ikkuntattja persunal tas-servizz kwalifikat.

8. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-MudellPDE07K3SG
BrandFriedrich
Dimensjonijiet tal-Prodott26 x 44 x 19 pulzieri
Kapaċità tat-tkessiħ7200/7000 BtuH
Kapaċità tat-tisħin11,700/9600 BtuH
Voltage230/208 Volts
EER (Proporzjon tal-Effiċjenza tal-Enerġija)13.0/13.0
kW tat-tisħin3.5
Frekwenza60 Hz
Fażi1 Fażi
Min. Ċirkwit Amps19.0
Provvista tal-Enerġija20A
Tul tal-Kunda tal-Enerġija5 pied.
Konfigurazzjoni tal-Plagg NEMA6-20P
Tip ta 'RefriġerantR-410A
Kapaċità0.6 Tunnellata
Livell ta' Storbju50 Deċibel
Karatteristika SpeċjaliTisħin
Proporzjon tal-Effiċjenza Enerġetika Staġjonali (SEER)13

9. Informazzjoni dwar Garanzija

Friedrich products are manufactured to high-quality standards. For specific warranty terms and conditions applicable to your PDE07K3SG unit, please refer to the warranty card included with your purchase or visit the official Friedrich websit. Żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.

10. Appoġġ għall-Klijent

If you have questions, require technical assistance, or need to schedule service, please contact Friedrich customer support. Contact information can typically be found on the manufacturer's webis-sit jew fuq l-imballaġġ tal-prodott.

Għal aktar għajnuna, żur: www.friedrich.com

Dokumenti Relatati - PDE07K3SG

Preview Friedrich FreshAire® Packaged Terminal Air Conditioners (PTAC) Product Profile u Speċifikazzjonijiet
Comprehensive product profile and technical specifications for Friedrich FreshAire® Packaged Terminal Air Conditioners (PTAC). Details features like make-up air compliance with ASHRAE 62.1, inverter technology, low sound levels, humidity control, and indoor air quality (IAQ) readiness. Includes model details, performance data, electrical specifications, installation guidance, and warranty information.
Preview Manwal tas-Servizz tal-PTAC tas-Serje Friedrich ZoneAire Premier R-32
Comprehensive service manual for Friedrich ZoneAire Premier R-32 Series Packaged Terminal Air Conditioners (PTAC) and Heat Pumps. Covers specifications, operation, troubleshooting, component testing, and repair procedures for models using R-32 refrigerant.
Preview Friedrich Zoneaire Select R-32 Series PTAC Service Manual
This service manual provides detailed technical information, troubleshooting guides, and repair procedures for Friedrich Zoneaire Select R-32 Series PTAC and Heat Pump units, including standard chassis models.
Preview Friedrich Hazardgard® Air Conditioners for Hazardous Locations | Datasheet
Friedrich Hazardgard® air conditioners are engineered for extreme environments, meeting UL Class 1, Div 2 and T4 temperature classification. Designed for hazardous locations like laboratories, control rooms, and industrial sites, they offer robust reliability, durability, and corrosion resistance. Explore specifications, features, and applications for safe and effective cooling.
Preview Kondizzjonaturi tal-Arja tal-Kamra Friedrich Kühl: Speċifikazzjonijiet, Gwida għall-Installazzjoni u d-Daqsijiet
Gwida komprensiva għall-arja kondizzjonata tal-kamra tas-Serje Friedrich Kühl, li tkopri speċifikazzjonijiet dettaljati, proċeduri ta' installazzjoni, rakkomandazzjonijiet dwar id-daqs, u karatteristiċi ewlenin għal prestazzjoni ottimali tat-tkessiħ u t-tisħin.
Preview Friedrich ZoneAire Premier R-32 Series PTAC Installation and Operation Manual
Comprehensive installation and operation manual for Friedrich ZoneAire Premier R-32 Series PTAC Packaged Terminal Air Conditioners and Heat Pumps, covering safety, specifications, installation, electrical, startup, troubleshooting, accessories, and warranty.