YSI 251401Y

Manwal tal-Utent tar-Reaġent tat-Trab tal-Kloru Ħieles YSI 251401Y DPD

For pHotoFlex and 900 Chlorine Colorimeter

1. Prodott Aktarview

The YSI 251401Y DPD Free Chlorine Reagent Powder is an EPA-approved chemical reagent designed for accurate measurement of free chlorine concentrations. This product is specifically formulated for use with YSI pHotoFlex and 900 Chlorine Colorimeter instruments, providing reliable results within a range of 0.02 to 2 mg/L. Each pack contains 100 individual 10ml volume powder packets, ensuring convenience and consistent dosing for laboratory and field applications.

YSI 251401Y DPD Free Chlorine Reagent Powder Packet

Image 1.1: A single packet of YSI 251401Y DPD Free Chlorine Reagent Powder. The label indicates "Powder Packets," "Part Number: 251401Y," "Lot Code: L 01 A," and "Exp: 01.2017." It also includes safety warnings and manufacturer contact information.

2. Safety Information and Handling

This product is intended for professional laboratory and field use only. Adherence to all safety guidelines is critical for proper and safe operation.

3. Setup u Preparazzjoni

Before beginning any measurement, ensure you have the necessary equipment and that your colorimeter is calibrated according to its specific user manual.

3.1 Required Materials (Not Included)

3.2 Preparazzjoni tar-Reaġent

The YSI 251401Y DPD Free Chlorine Reagent is provided in pre-measured powder packets, eliminating the need for manual weighing or dilution. Each packet contains the precise amount of reagent for a 10ml sampil-volum.

4. Operating Instructions for Free Chlorine Measurement

Follow these steps for accurate free chlorine measurement using the YSI 251401Y DPD Free Chlorine Reagent Powder with a compatible YSI colorimeter.

  1. Ipprepara SampĊellula: Rinse a clean sample cell thoroughly with deionized water, then with a small amount of the sample jkun ittestjat.
  2. Imla SampĊellula: Imla l-sample cell with 10 ml of the water sample to be analyzed. Ensure the sample volume is precise.
  3. Żid ir-Reaġent: Carefully open one YSI 251401Y DPD Free Chlorine Reagent Powder packet. Add the entire contents of the powder packet to the 10 ml sample fiċ-ċellola.
  4. Ħallat: Kap is-sample cell and invert it gently several times to dissolve the powder completely. Avoid shaking vigorously, which can introduce air bubbles. A pink color will develop if free chlorine is present.
  5. Ħin ta' Reazzjoni: Allow a reaction time of approximately 1 minute for the color to fully develop. Consult your colorimeter's manual for specific reaction time recommendations.
  6. Miżura: Daħħal l-s ippreparatample cell into the YSI pHotoFlex or 900 Chlorine Colorimeter. Follow the instrument's instructions to initiate the measurement. The colorimeter will display the free chlorine concentration in mg/L.
  7. Riżultati tar-Reġistrazzjoni: Record the measurement results immediately.
  8. Naddaf: After measurement, empty the sample cell and rinse it thoroughly with deionized water.

Nota: For best results, perform measurements promptly after sample collection. The DPD method is sensitive to light and temperature; protect samples and reagents from direct sunlight and extreme temperatures.

5. Manutenzjoni u Ħażna

Proper storage of the reagent packets is essential to maintain their integrity and ensure accurate results.

6 Issolvi l-problemi

This section addresses common issues that may arise during the use of the DPD Free Chlorine Reagent.

ProblemaKawża PossibbliSoluzzjoni
No color development or faint color when chlorine is expected.
  • Expired reagent.
  • Insufficient mixing.
  • Sample pH outside optimal range.
  • Interfering substances in sample.
  • Check expiration date; use fresh reagent.
  • Ensure complete dissolution of powder.
  • Verify sample pH is within the colorimeter's specified range for DPD method.
  • Consult colorimeter manual for known interferences.
Inconsistent or erratic readings.
  • Mhux xieraq sampil-volum.
  • Kontaminat sample ċelluli.
  • Air bubbles in sample cell.
  • Colorimeter calibration issue.
  • Ensure precise 10 ml sampil-volum.
  • Thoroughly clean sample cells before each use.
  • Gently invert to mix, avoid vigorous shaking.
  • Perform colorimeter calibration as per instrument manual.

7. Speċifikazzjonijiet

8. Garanzija u Appoġġ

For technical support, product inquiries, or to request a Safety Data Sheet (SDS), please contact YSI directly using the information below.

YSI stands behind the quality of its products. Please refer to the official YSI website or contact customer support for detailed warranty information applicable to this reagent.

Dokumenti Relatati - 251401Y

Preview YSI Model 32 Conductance Meter Instruction Manual
Instruction manual for the YSI Model 32 Conductance Meter, detailing its general description, specifications, operating procedures, maintenance, and calibration.
Preview Gwida ta' Bidu Mgħaġġel tal-YSI Pro20/Pro20i: Kalibrazzjoni u Tħaddim
Gwida konċiża għall-kalibrazzjoni u t-tħaddim tal-miters tal-ossiġnu maħlul YSI Pro20/Pro20i, li tkopri l-installazzjoni tal-membrana, is-setup tas-sensuri, il-kalibrazzjoni tal-barometru u tad-DO, il-kumpens tas-salinità, u t-teħid tal-kejl. Tinkludi passi operattivi essenzjali u informazzjoni ta' kuntatt.
Preview Soluzzjoni Buffer YSI 3821 pH 4.00 Skeda ta' Dejta dwar is-Sigurtà (SDS)
Skeda ta' Dejta dwar is-Sigurtà (SDS) Komprensiva għas-Soluzzjoni Buffer YSI 3821 pH 4.00, li tiddeskrivi l-identifikazzjoni tal-prodott, il-perikli, il-kompożizzjoni, l-ewwel għajnuna, l-immaniġġjar, il-ħażna, u informazzjoni regolatorja.
Preview Manwal tal-Utent tal-Istrumenti tal-Ossiġnu Maħlul u t-Temperatura YSI EcoSense DO200A/DO200M
Dan il-manwal tal-utent jipprovdi struzzjonijiet komprensivi għat-tħaddim, l-installazzjoni, il-manutenzjoni, u s-soluzzjoni tal-problemi tal-istrumenti tal-ossiġnu maħlul u t-temperatura YSI EcoSense DO200A u DO200M. Jinkludi dettalji dwar l-ispeċifikazzjonijiet, l-aċċessorji, u informazzjoni dwar il-garanzija.
Preview YSIT-1 Satellite Transmitter Operation and Maintenance Manual
Comprehensive user manual for the YSI Model YSIT-1 Satellite Transmitter, covering its operation, maintenance, hardware setup, and serial command reference. Details include time management, data storage, GOES data formatting, RF transmitter control, and GPS synchronization.
Preview YSI IQ Sensor Net MIQ/CHV PLUS Operating Manual
This operating manual provides detailed instructions for the YSI IQ Sensor Net MIQ/CHV PLUS valve module, covering installation, settings, maintenance, and safety guidelines for compressed air-operated sensor cleaning heads.