THERMCO ACC3105DIG

Thermco ACC3105DIG Digital Thermometer User Manual

Model: ACC3105DIG

Introduzzjoni

The Thermco ACC3105DIG Laboratory Long Stem Digital Thermometer is designed for precise temperature measurements in laboratory and industrial settings. It features a long stem for reaching into various containers and offers high accuracy with a wide temperature range. Each unit is manufactured to exacting standards and comes with a NIST traceable certificate, ensuring reliability and precision.

Prodott Overview

Thermco ACC3105DIG Digital Thermometer with white body and red stem

Figura 1: Thermco ACC3105DIG Digital Thermometer. This image displays the thermometer with a white main body and a long red stainless steel stem. The digital display shows a temperature reading, and control buttons for 'HOLD', 'MAX/MIN', 'ON-OFF', and '°C/°F' are visible on the front panel. The stem is angled downwards from the main unit.

Setup

1. Spakkjar

Carefully remove the thermometer from its packaging. Inspect the device for any visible damage. Retain the packaging for future storage or transport.

2. Installazzjoni/Kontroll tal-Batterija

The thermometer is battery-powered. Ensure the battery is correctly installed. If the display does not light up, replace the battery according to the instructions in the Maintenance section.

3. L-Ewwel Tixgħil

Agħfas il- ON-OFF button to power on the device. The display should illuminate and show the current temperature.

Istruzzjonijiet Operattivi

1. Power On/Off

2. Kejl tat-Temperatura

  1. Insert the stainless steel stem into the substance or environment to be measured. Ensure the stem is sufficiently immersed for accurate readings.
  2. Wait for the temperature reading on the digital display to stabilize. This may take a few seconds depending on the temperature difference.

3. Unit Selection (°C/°F)

Agħfas il- ° C / ° F button to switch between Celsius and Fahrenheit temperature units. The selected unit will be indicated on the display.

4. Funzjoni HOLD

Agħfas il- ŻOMM button to freeze the current temperature reading on the display. This is useful for recording readings in hard-to-reach areas. Press the ŻOMM button again to release the reading and return to live measurement.

5. Funzjoni MAX/MIN

Agħfas il- MAX/MIN buttuna biex view the maximum or minimum temperature recorded since the device was powered on or the function was reset. Subsequent presses will cycle through MAX, MIN, and current temperature display. To reset the MAX/MIN values, typically hold the button down or power cycle the device.

Manutenzjoni

1. Tindif

Wipe the thermometer stem and body with a damp cloth. For sterilization, the stainless steel stem can be cleaned with appropriate laboratory disinfectants. Do not immerse the main body of the thermometer in liquid.

2. Ħażna

Store the thermometer in a clean, dry place away from extreme temperatures and direct sunlight. Use the protective sleeve or case if provided.

3. Sostituzzjoni tal-batterija

When the display becomes dim or erratic, it's time to replace the battery. Locate the battery compartment, usually on the back or side of the main unit. Open it, remove the old battery, and insert a new one of the same type, observing polarity. Close the compartment securely.

Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
L-ebda wiri jew wiri mudlamBatterija baxxa jew mejta; installazzjoni ħażina tal-batterija.Ibdel il-batterija; kun żgur li l-polarità hija korretta.
Qari mhux eżattInsufficient immersion of stem; sensor contamination; extreme environmental conditions.Ensure proper immersion depth; clean the stem; allow thermometer to acclimate to environment.
Buttuni ma jirrisponduxBattery issue; internal malfunction.Ibdel il-batterija. Jekk il-problema tippersisti, ikkuntattja l-appoġġ għall-klijenti.

Speċifikazzjonijiet

Dokumenti Relatati - ACC3105DIG

Preview Thermco ACCRT8017 Dual Data Logging Thermometer User Manual & Specifications
User manual for the Thermco ACCRT8017 Dual Data Logging Thermometer. Features dual probes, high accuracy, large data logging capacity (24 million readings), user-configurable alarms, and CSV data format for fridge and freezer monitoring.
Preview THERMCO ACCRT8019UL Dual Data Logging Thermometer - Ultra Low Freezer
Detailed specifications, features, and operating instructions for the THERMCO ACCRT8019UL Dual Data Logging Thermometer. This device monitors ultra-low freezers with dual probes, offers SD card data logging, and user-configurable alarms.
Preview Termometru tal-Friġġ/Friżer bi Tliet Wirjiet McKesson | MCK895RFV
Informazzjoni dettaljata dwar it-Termometru tar-Refriġeratur/Friżer b'Ċifri Kbar b'Displej Triplu ta' McKesson b'Sonda Unika (MCK895RFV), inklużi l-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim, u s-settings tal-allarm. Traċċabbli skont in-NIST.
Preview Manwal tal-Utent u Speċifikazzjonijiet tat-Termometru tal-Infra-aħmar tal-Fuq AccuTherm™ CARE4U
Gwida komprensiva għat-Termometru Infrared Kliniku tal-Front AccuTherm™ CARE4U, li tkopri struzzjonijiet dwar l-operat, gwida dwar il-kejl, manutenzjoni, prekawzjonijiet, u speċifikazzjonijiet tekniċi. Tgħallem kif tuża u tieħu ħsieb it-termometru AccuTherm tiegħek.
Preview Manwal tal-Utent tat-Termometru tar-Refriġeratur/Friżer McKesson DUAL PROBE MCK8100MATB
Manwal dettaljat għall-utent għat-Termometru tar-Refriġeratur/Friżer McKesson DUAL PROBE (MCK8100MATB). Jinkludi karatteristiċi, speċifikazzjonijiet, struzzjonijiet ta' setup, konfigurazzjoni tas-settings, u noti għas-soluzzjoni tal-problemi.
Preview Thermco ACC895WRFT Wireless Min-Max Alarm Thermometer User Manual
User manual for the Thermco ACC895WRFT Wireless Min-Max Alarm Thermometer. Features include 3-channel measurement, programmable alarms, ambient/external/wireless temperature display, and a foldaway stand. Includes installation, operation, troubleshooting, and specifications.