1. Introduzzjoni
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Finder 140182300000PAS Multifunction Timer/Staircase Relay. Please read this manual carefully before installation and use to ensure proper function and safety.
2. Informazzjoni dwar is-Sigurtà
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel in accordance with all local and national electrical codes.
- Dejjem skonnettja l-enerġija qabel ma tinstalla jew tagħmel manutenzjoni fuq l-apparat.
- Ensure the device is installed in a suitable enclosure to protect against environmental factors.
- Verify correct wiring connections to prevent damage to the device or connected equipment.
- Taqbiżx il-vol speċifikattage u klassifikazzjonijiet kurrenti.
3. Prodott Aktarview
The Finder 140182300000PAS is a versatile multifunction timer and staircase relay designed for various electrical control applications. It features a 230V operating voltage, a 1 NO (normally open) contact, and a 16A current rating. Its compact design allows for easy integration into electrical panels.

Figura 1: Quddiem view of the Finder 140182300000PAS Multifunction Timer/Staircase Relay. This image shows the device's casing, terminals, and the adjustable timer dial.

Figura 2: Example application of the Finder 140182300000PAS controlling staircase lighting. The relay is shown in an inset, demonstrating its use in a typical residential or commercial setting.

Figura 3: Another application example, showing the Finder 140182300000PAS managing lighting for a modern spiral staircase. This highlights the device's suitability for various architectural lighting designs.
4. Setup u Installazzjoni
4.1 Dimensjonijiet Fiżiċi
Refer to the dimensional drawing for precise measurements to ensure proper fit and mounting.

Figura 4: Dimensional drawing for the Type 14.01 relay, showing height, width, and depth in millimeters. This diagram is crucial for planning installation space.
4.2 Dijagrammi tal-Wiring
The Finder 140182300000PAS supports both 3-wire and 4-wire connection types. Select the appropriate diagram for your installation.

Figura 5: Wiring Diagram Type 14.01 for a 3-wire connection. This diagram illustrates how to connect the relay to the power supply and load using a 3-wire configuration, typically for staircase lighting with a common neutral.

Figura 6: Wiring Diagram Type 14.01 for a 4-wire connection. This diagram shows the connections for a 4-wire setup, which might be used in systems requiring separate control wires for the relay and the load.
5. Istruzzjonijiet Operattivi
5.1 Aġġustament tat-Tajmer
The device features an adjustable timer dial on its front face. To set the desired timing duration:
- Locate the orange dial labeled 'T(min)' on the front of the relay.
- Rotate the dial to align the indicator with the desired time setting (e.g., 5, 10, 15, 20 minutes).
- The selected time will determine how long the connected load remains active after activation.
5.2 Multifunction Operation
The Finder 140182300000PAS operates as both a staircase timer and a multifunction relay. When activated (e.g., by a push-button switch), the relay will close its contact, powering the connected load for the duration set on the timer. It can be used for applications such as:
- Staircase lighting control.
- Timed ventilation systems.
- General purpose timed switching.
6. Manutenzjoni
The Finder 140182300000PAS is designed for long-term, maintenance-free operation. However, periodic checks are recommended:
- Kun żgur li l-konnessjonijiet kollha tal-wajers jibqgħu sikuri.
- Żomm l-apparat ħieles mit-trab u l-fdalijiet.
- Inspect for any signs of physical damage or overheating.
- If the device is exposed to harsh environments, consider more frequent inspections.
TWISSIJA: Dejjem skonnettja l-enerġija qabel ma twettaq kwalunkwe manutenzjoni jew spezzjoni.
7 Issolvi l-problemi
Jekk l-apparat mhux qed jaħdem kif mistenni, ikkunsidra dan li ġej:
- No power to the load: Check the main power supply, circuit breaker, and all wiring connections. Ensure the device is receiving 230V.
- Timer not activating: Verify the input signal (e.g., from the push-button switch) is correctly connected and functioning.
- Incorrect timing duration: Re-check the setting on the 'T(min)' dial.
- Tisħin żejjed tal-apparat: Ensure the load current does not exceed 16A. Check for proper ventilation around the device.
If issues persist after checking these points, consult a qualified electrician or contact Finder customer support.
8. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Manifattur | Finder |
| Numru tal-Mudell | 140182300000PAS |
| Dimensjonijiet tal-Prodott (L x W x H) | 8.4 x 1.8 x 5.9 ċm |
| Piż | 60 gramma |
| Kulur | Griż |
| Materjal | Plastik |
| Voltage | 230 Volts |
| Tip ta' Kuntatt | 1 LE (Normalment Miftuħ) |
| Klassifikazzjoni kurrenti | 16 A |
| Numru ta' Settings | 8 (Timer functions) |
| Batterija(jiet) Inkluża(i) | Nru |
| Batterija(jiet) Meħtieġa | Nru |
| Disponibbiltà ta' Spare Parts | Informazzjoni mhux disponibbli |
8.1 Ċertifikazzjonijiet
The product complies with various international standards.

Figura 7: Product certifications, including CE, UKCA, EAC, and Q-Mark, indicating compliance with European, UK, Eurasian, and quality standards respectively.
9. Garanzija u Appoġġ
For warranty information and technical support, please refer to the official Finder webis-sit jew ikkuntattja lid-distributur lokali tiegħek. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri.