1. Prodott Aktarview

The Fluke 325 True-RMS Clamp Meter is a versatile and reliable tool designed for general electrical troubleshooting. It accurately measures AC current, AC and DC voltage, resistance, frequency, temperature, and capacitance. Its compact design and robust construction make it suitable for various industrial and residential applications.

Fluke 325 True-RMS Clamp Miter

Immaġni: Quddiem view of the Fluke 325 True-RMS Clamp Meter, displaying its digital screen and function dial.

Karatteristiċi ewlenin:

  • Diġitali clamp meter measures AC current up to 400 A, AC and DC voltage up to 600 V, and resistance up to 4 kΩ.
  • True-RMS sensing provides accurate readings for linear and non-linear loads.
  • Jaw opening of 30 mm allows current measurement without interrupting the circuit.
  • Audible continuity sensor for quick circuit checks.
  • Meets IEC safety standard 61010-1, rated for CAT IV installations to 300 V and CAT III installations to 600 V.
  • Includes frequency, temperature, and capacitance measurement capabilities.

2. Informazzjoni Importanti dwar is-Sigurtà

Always read and understand the safety instructions before using the Fluke 325 Clamp Meter. Failure to follow safety warnings can result in serious injury or death.

  • Tużax il-miter jekk ikun bil-ħsara jew jekk ikun qed jaħdem b'mod mhux normali.
  • Ivverifika l-operazzjoni tal-miter fuq volum magħruftagis-sors elettroniku qabel l-użu.
  • Oqgħod attent meta taħdem bil-voltages above 30 V AC RMS, 42 V AC peak, or 60 V DC. These voltages joħolqu periklu ta' xokk.
  • Always use the proper terminals, function, and range for your measurements.
  • Żomm subgħajk wara l-protezzjonijiet tas-swaba' fuq il-probes tat-test.
  • The Fluke 325 is rated for CAT IV 300 V and CAT III 600 V. Ensure the meter's rating is appropriate for the environment where it will be used.

3. Nibdew: Konfigurazzjoni

Installazzjoni tal-batterija

The Fluke 325 requires two AA batteries (included). To install or replace batteries:

  1. Kun żgur li l-miter ikun MITFI.
  2. Sib il-kompartiment tal-batterija fuq wara tal-miter.
  3. Uża tornavit biex tiftaħ l-għatu tal-kompartiment tal-batterija.
  4. Insert two AA batteries, observing correct polarity.
  5. Ibdel l-għatu tal-kompartiment tal-batterija u waħħalha bil-kamin.

Konnessjoni taċ-Ċombijiet tat-Test

Għal voltage, resistance, continuity, frequency, temperature, and capacitance measurements, connect the test leads to the appropriate input jacks:

  • Insert the black test lead into the COM (common) jack.
  • Insert the red test lead into the VΩHz jack for most measurements.
Fluke 325 Clamp Meter with included test leads and carrying case

Image: The Fluke 325 Clamp Meter displayed with its test leads, temperature probe, and soft carrying case.

4. Operating Your Fluke 325

Dial tas-Selettur tal-Funzjoni

The large yellow rotary dial on the front of the meter is used to select the desired measurement function. Turn the dial to the appropriate setting for your task.

Kejl tal-Kurrent AC/DC (Clamp)

Biex tkejjel il-kurrent AC jew DC:

  1. Turn the function dial to the ∼A (AC current) or =A (DC current) position.
  2. Iftaħ il-clamp jaws by pressing the lever.
  3. Place the jaws around a single conductor. Ensure the jaws are fully closed.
  4. Aqra l-valur attwali fuq id-displej.
Electrician using Fluke 325 Clamp Meter to measure current in an electrical panel

Image: A gloved hand using the Fluke 325 Clamp Meter to measure current on a wire within an electrical panel, showing a reading of 38.7 A.

VoltagKejl elettroniku (AC/DC)

Biex tkejjel AC jew DC voltage:

  1. Connect the test leads as described in the 'Connecting Test Leads' section.
  2. Turn the function dial to the ∼V (AC voltage) or =V (DC voltage) pożizzjoni.
  3. Tmiss il-probi tat-test mal-punti taċ-ċirkwit fejn il-volumtage għandu jitkejjel.
  4. Aqra l-voltagIl-valur fuq il-wiri.

Reżistenza u Kontinwità

To measure resistance or check continuity:

  1. Qabbad il-wajers tat-test.
  2. Turn the function dial to the Ω (resistance/continuity) position.
  3. Touch the test probes across the component or circuit path.
  4. For resistance, read the value on the display. For continuity, the meter will beep if a continuous path is detected.

Frequency, Temperature, and Capacitance

The Fluke 325 also offers specialized measurements:

  • Frekwenza (Hz): Select the Hz function to measure the frequency of AC signals.
  • Temperatura (°C/°F): Use the included temperature probe and select the temperature function to measure temperature.
  • Kapaċità: Select the capacitance function to measure the capacitance of components.

True-RMS Accuracy

The True-RMS feature ensures accurate measurements of AC voltage and current, even when waveforms are distorted or non-sinusoidal. This is crucial for modern electrical systems with non-linear loads.

Wiri ta 'backlit

The Fluke 325 features a backlit display for improved visibility in dimly lit environments. Press the backlight button to activate or deactivate the backlight.

Video: Official Fluke overview of the 32X series True-RMS Clamp Meters, highlighting features like compact design, safety ratings, True-RMS accuracy, backlit display, temperature measurements, and DC current measurement (for 325 model).

5. Manutenzjoni u Kura

Tindif

To clean the meter, wipe it with a damp drapp u deterġent ħafif. Tużax abrażivi jew solventi. Kun żgur li l-miter ikun niexef għalkollox qabel l-użu.

Sostituzzjoni tal-batterija

When the battery indicator appears on the display, replace the batteries as described in the 'Battery Installation' section.

Ħażna

Store the meter in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.

6. Issolvi l-problemi ta' Kwistjonijiet Komuni

  • Ebda Wiri/Qawwa: Iċċekkja l-installazzjoni tal-batterija u kun żgur li l-batteriji mhumiex eżawriti.
  • Qari mhux eżatt: Verify correct function and range selection. Ensure test leads are properly connected and not damaged. For current measurements, ensure the clamp jaws are fully closed around a single conductor.
  • Continuity Beeper Not Working: Check if the function dial is set to continuity and test leads are making good contact.
  • 'OL' on Display: This indicates an overload or out-of-range measurement. Select a higher range or ensure the measured value is within the meter's specifications.

7. Speċifikazzjonijiet Tekniċi

SpeċifikazzjoniValur
Numru tal-MudellFLUKE-325
Kurrent AC400 A
Kurrent DC400 A
AC Voltage600 V
DC Voltage600 V
Reżistenza4kΩ
FrekwenzaIva
TemperaturaIva
KapaċitàIva
Klassifikazzjoni tas-SigurtàCAT IV 300 V, CAT III 600 V
Sors tal-Enerġija2 batteriji AA
Piż tal-oġġett295 Gram (10.41 uqija)
Dimensjonijiet9.45 x 11 x 3.15 pulzieri

8. Garanzija u Appoġġ għall-Klijent

Fluke products are known for their quality and reliability. For specific warranty details and terms, please refer to the warranty card included with your product or visit the official Fluke website. For technical assistance, troubleshooting, or service, please contact Fluke customer support directly.

Riżorsi onlajn: www.fluke.com

Dokumenti Relatati - FLUKE-325

Preview Fluke 323/324/325 Clamp Manwal tal-Utent tal-Miter - Speċifikazzjonijiet u Sigurtà
Manwal komprensiv għall-utent għall-Fluke 323, 324, u 325 Clamp Miters. Jinkludi informazzjoni dwar is-sigurtà, speċifikazzjonijiet elettriċi u mekkaniċi, u struzzjonijiet dwar it-tħaddim.
Preview Fluke 323/324/325 Clamp Manwal għall-Utent tal-Meter
Manwal tal-utent għall-Fluke 323, 324, u 325 True-RMS Clamp Miters, li jkopru informazzjoni dwar is-sigurtà, l-ispeċifikazzjonijiet, it-tħaddim u l-manutenzjoni.
Preview Fluke 323/324/325 Clamp Manwal għall-Utent tal-Meter
Manwal komprensiv għall-utent għal Fluke 323, 324, u 325 clamp miters, karatteristiċi dettaljati, prekawzjonijiet ta' sigurtà, speċifikazzjonijiet, u gwida operazzjonali għal kejl elettriku preċiż.
Preview Fluke 381 Wiri Remot True-rms Clamp Manwal għall-Utent tal-Meter
Manwal komprensiv għall-utent għall-Fluke 381 Remote Display True-rms Clamp Miter. Ikopri l-karatteristiċi tal-prodott, proċeduri ta' kejl għall-kurrent AC/DC, voltage, reżistenza, frekwenza, kurrent qawwi, manutenzjoni, speċifikazzjonijiet, u informazzjoni dwar is-sigurtà. Jinkludi deskrizzjonijiet dettaljati ta' dijagrammi u tabelli.
Preview Fluke 373 True-RMS AC Clamp Miter - Speċifikazzjonijiet Tekniċi u Aktarview
Dejta teknika dettaljata, karatteristiċi ewlenin, prodott fuqview, speċifikazzjonijiet, u informazzjoni dwar l-ordnijiet għall-Fluke 373 True-RMS AC Clamp Miter, iddisinjat għal kejl tal-kurrent AC biss sa 600 A.
Preview Multimetru True-RMS Fluke 110: Speċifikazzjonijiet Tekniċi u Karatteristiċi
Speċifikazzjonijiet u karatteristiċi dettaljati tal-multimetru kompatt True-RMS Fluke 110, iddisinjat għal installazzjoni elettrika preċiża u s-soluzzjoni ta' problemi. Jinkludi l-eżattezza, il-klassifikazzjonijiet tas-sigurtà, u l-aċċessorji inklużi.