KING HWP120

KING HWP120 Linja Elettronika Voltage Programmable Hydronic System Thermostat

Model: HWP120

Introduzzjoni

The KING HWP120 is an advanced electronic line voltage programmable thermostat designed specifically for hydronic heating systems. This thermostat offers precise temperature control and energy savings through its 7-day independent programming capabilities, allowing for up to four time and temperature settings per day. Its user-friendly design features an illuminated LCD display and simple two-button operation for setting temperature and navigating menus. The HWP120 is equipped with memory backup to retain settings during power outages, ensuring consistent comfort.

KING HWP120 Thermostat angled view

Figura 1: Angolat view of the KING HWP120 Electronic Line Voltage Programmable Hydronic System Thermostat, showing its white casing and green illuminated LCD display.

Informazzjoni dwar is-Sigurtà

TWISSIJA: To prevent electric shock or damage to the thermostat, disconnect power to the heating system at the main fuse or circuit breaker box before installation or servicing. This thermostat operates on line voltage (120V/240V) and requires careful handling. Installation should only be performed by a qualified electrician in accordance with local electrical codes.

Installazzjoni u Setup

Proper installation is crucial for the safe and efficient operation of your HWP120 thermostat. It is recommended that a licensed electrician perform the installation.

Post tal-Immuntar

Choose a location on an interior wall, approximately 5 feet (1.5 meters) above the floor, away from direct sunlight, drafts, or heat sources (e.g., lamps, appliances, fireplaces). These factors can affect the thermostat's temperature readings.

Istruzzjonijiet tal-Wiring

  1. Skonnettja l-Enerġija: Turn off the power to your heating system at the main circuit breaker. Verify power is off before proceeding.
  2. Neħħi Termostat Qadim: Carefully remove your existing thermostat from the wall. Note the wiring connections.
  3. Qabbad il-Wiring: Connect the wires from your heating system to the appropriate terminals on the HWP120 thermostat. Refer to the wiring diagram provided with your thermostat's packaging for specific connections. Ensure all connections are tight.
  4. Termostat tal-Immuntar: Secure the HWP120 thermostat to the wall using the provided mounting screws.
  5. Irrestawra l-Enerġija: Ladarba l-installazzjoni tkun tlestiet u l-konnessjonijiet kollha jkunu siguri, erġa' daħħal l-enerġija fis-circuit breaker.
Quddiem view of KING HWP120 Thermostat

Figura 2: Quddiem view of the KING HWP120 Thermostat, highlighting the LCD display and the two control buttons below it.

Istruzzjonijiet Operattivi

The HWP120 thermostat is designed for straightforward operation using its two primary buttons and illuminated LCD display.

Uri Fuqview

The LCD display shows the current room temperature, the set temperature, the time, day of the week, and the active program period (P1, P2, P3, P4). When the heating system is active, a "HEAT" indicator will typically be visible.

Angolat tal-ġenb view of KING HWP120 Thermostat

Figura 3: Angolat mal-ġenb view of the KING HWP120 Thermostat, showing the ventilation grilles on the side and the clear display.

Adjusting Temperature Manually

To temporarily adjust the temperature, press the Up () jew Down () buttons. The display will show the new set temperature. This manual override will typically remain active until the next programmed period begins.

L-issettjar tal-Ħin u l-Jum

Refer to the detailed programming section for initial setup of time and day, as these are integral to the programming functions.

Istruzzjonijiet għall-Ipprogrammar

The HWP120 allows for 7 independent day programming with 4 times and temperature settings (P1, P2, P3, P4) per day. This feature helps optimize energy consumption by adjusting heating based on your schedule.

Dħul fil-Modalità ta' Programmazzjoni

To enter programming mode, press and hold both the Up () u Down () buttons simultaneously for a few seconds until the display changes to indicate programming mode (e.g., flashing time or day).

L-issettjar tal-Ħin u l-Jum

  1. In programming mode, the hour will typically flash. Use the Up or Down buttuni biex taġġusta s-siegħa.
  2. Press one of the buttons (e.g., Up or Down, depending on the model's specific navigation) to advance to minutes, then adjust.
  3. Continue to advance to set the day of the week.

Setting Program Periods (P1-P4)

For each day of the week, you can set four distinct periods:

  1. While in programming mode, navigate to the desired day (e.g., Monday).
  2. Select P1. Set the desired start time and temperature for P1 using the Up or Down buttuni.
  3. Advance to P2 and repeat the process for its start time and temperature.
  4. Continue for P3 and P4.
  5. Repeat this process for each day of the week (Tuesday through Sunday).
  6. Ħruġ mill-Modalità ta' Programmazzjoni: Once all settings are complete, the thermostat will typically exit programming mode automatically after a period of inactivity, or you may need to press and hold the buttons again to save and exit. Consult the full manual for specific exit procedures.

Nota Importanti: The HWP120 thermostat initiates heating at the programmed time to reach the set temperature. It does not anticipate heating. Therefore, if you desire a room to be at a specific temperature by a certain time, set the program to begin heating approximately 15-30 minutes prior to that desired time, depending on your system's response time.

Manutenzjoni

The KING HWP120 thermostat requires minimal maintenance to ensure optimal performance.

Issolvi l-problemi

If you encounter issues with your HWP120 thermostat, refer to the following common problems and solutions:

ProblemaKawża PossibbliSoluzzjoni
Il-wiri tat-termostat huwa vojt.L-ebda enerġija għat-termostat.Check the circuit breaker for your heating system. Ensure it is in the "ON" position. Verify wiring connections.
Heating system not turning on/off as programmed.Incorrect programming; manual override active; system malfunction.Review your program settings carefully. Ensure no manual override is active. Check your heating system for other issues.
Room temperature inaccurate.Il-post tat-termostat huwa affettwat minn kurrenti tal-arja jew sorsi ta' sħana.Ensure the thermostat is not exposed to direct sunlight, drafts from windows/doors, or heat from appliances.
Difficulty programming.Unfamiliarity with programming sequence.Carefully re-read the "Programming Instructions" section. Practice the steps without making permanent changes.

If problems persist after attempting these solutions, contact a qualified electrician or KING customer support for assistance.

Speċifikazzjonijiet

KaratteristikaDettall
Isem tal-MudellHWP120
BrandRE
Voltage120 Volt / 240 Volt
Ampetà12.5 amps (120V) / 12.5 amps (240V)
Wattage1500 watts (120V) / 3000 watts (240V)
Firxa tat-Temperatura44°F sa 95°F (7°C sa 35°C)
Eżattezza± 1.2°F @ 10 amps, ± .9°F @ 4.2 amps
Programmazzjoni7 independent day programming with 4 times and temperature settings per day
Tip ta 'WiriDigital, Illuminated LCD
Tip ta' KontrollImbotta Buttuna
MaterjalPlastik
Dimensjonijiet (L x W x H)4.88 x 3.13 x 2 pulzieri
Piż tal-oġġett10.4 uqija

Garanzija u Appoġġ

Informazzjoni dwar Garanzija

The KING HWP120 Electronic Line Voltage Programmable Hydronic System Thermostat comes with a Garanzija limitata ta 'sena from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, please refer to the warranty documentation included with your product or visit the manufacturer's official websit.

Appoġġ għall-Klijent

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact KING customer support. You can typically find contact information (phone number, email, or support portal) on the manufacturer's websit jew fl-ippakkjar tal-prodott.

It is recommended to have your product model number (HWP120) and date of purchase available when contacting support.

Dokumenti Relatati - HWP120

Preview Ħiters tal-Ħajt Idroniċi tas-Serje King H: Gwida għall-Installazzjoni u Speċifikazzjonijiet
Istruzzjonijiet komprensivi għall-installazzjoni, twissijiet ta' sigurtà, linji gwida għall-immuntar, dijagrammi tal-wajers, u speċifikazzjonijiet tal-prodott għall-Heaters tal-Ħajt Idroniċi tas-Serje King H. Jinkludi dettalji tal-mudell, klassifikazzjonijiet BTU, u kompatibilità mat-termostat.
Preview Kit tat-Termostat RF Wireless 24V King KRF-HEAT-KIT għall-Kontroll tas-Sħana Elettrika
Gwida komprensiva għall-King KRF-HEAT-KIT, sistema ta' termostat mingħajr fili RF ta' 24V iddisinjata għal vultaġġ tal-linjatagKontroll tas-sħana elettrika. Il-karatteristiċi jinkludu t-termostat programmabbli KRFTP-B u r-relay KRFLR-120/240V, bi speċifikazzjonijiet dettaljati, informazzjoni dwar l-ordnijiet, u aċċessorji fakultattivi għal kontroll imtejjeb u ffrankar tal-enerġija.
Preview King Electric Thermostats and Controls Catalog
Comprehensive catalog of King Electric's line voltage u vol baxxtage thermostats, programmable and non-programmable models, including ATMOZ WIFI, Clear Touch, SIMPLSTAT, ES, ESP, WR, HP, K101, K102, K101-C, EP3, TF115, HW, HWP, HWPT, HB, HBP, F912GFCI, F902GFCI, CWR IceFree, SnowFree, PYRO, and FPC series. Features include energy saving, advanced sensing, and smart home integration.
Preview Gwida għall-Installazzjoni, il-Wajers, u l-Ipprogrammar tat-Termostat tas-Serje King HW-FS, HWP-FS, HWPT-FS 120V
Gwida komprensiva għat-termostati tas-serje HW-FS, HWP-FS, u HWPT-FS 120V ta' King Electric. Tkopri informazzjoni ġenerali, sigurtà, speċifikazzjonijiet, struzzjonijiet dwar il-wajers, programmazzjoni għal mudelli HWP/HWPT, installazzjoni, u manutenzjoni. Tinkludi dettalji dwar il-kontroll tat-temperatura għal sistemi ta' tisħin residenzjali u kummerċjali.
Preview Kit tat-Termostat RF King Wireless 24V KRF-24V-KIT għal Sistemi HVAC
Informazzjoni dwar il-Kit tat-Termostat King Wireless 24V RF (KRF-24V-KIT), li jinkludi t-termostat KRFTP-B u r-relay KRFR-24V HVAC. Id-dettalji jinkludu komunikazzjoni mingħajr fili, programmazzjoni, u aċċessorji fakultattivi għal kontroll imtejjeb tal-HVAC.
Preview Gwida għall-Installazzjoni u l-Manutenzjoni tal-Heater tas-Serje King LPW-ECO
Gwida komprensiva għall-installazzjoni, it-tħaddim, u l-manutenzjoni tal-ħiters elettroniċi tas-serje King LPW-ECO, inklużi struzzjonijiet ta' sigurtà, dijagrammi tal-wajers, setup tas-sensuri remoti, u s-soluzzjoni tal-problemi.