Belimo B213

Manwal tal-Istruzzjonijiet tal-Valv tal-Ballun Belimo B213

Mudell: B213

1. Introduzzjoni

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the Belimo B213 2-way 1/2-inch Stainless Steel Trim Ball Valve. Please read this manual thoroughly before proceeding with any procedures to ensure proper handling and to prevent potential hazards or damage to the product and system.

2. Informazzjoni dwar is-Sigurtà

Adherence to safety precautions is critical during all stages of installation, operation, and maintenance. Failure to follow these instructions may result in personal injury, property damage, or equipment malfunction.

3. Deskrizzjoni u Karatteristiċi tal-Prodott

The Belimo B213 is a high-quality 2-way ball valve designed for reliable flow control in various applications, including HVAC and industrial fluid systems. It features a durable construction with a 1/2-inch connection size and stainless steel trim for enhanced corrosion resistance and longevity. The valve is characterized by a flow coefficient (Cv) of 4.7, indicating its flow capacity.

Belimo B213 2-way 1/2-inch Stainless Steel Trim Ball Valve

Figura 1: Belimo B213 2-way 1/2-inch Stainless Steel Trim Ball Valve. This image shows the brass-colored valve body with threaded ends and a mounting base at the bottom, featuring a small chain attached.

4. Setup u Installazzjoni

Proper installation is crucial for the optimal performance and longevity of the Belimo B213 ball valve. It is recommended that installation be performed by a qualified technician.

  1. Preparazzjoni tas-Sistema: Ensure the system is completely shut down, depressurized, and drained before beginning installation.
  2. Tindif tal-Pajpijiet: Clean the pipe ends thoroughly to remove any debris, rust, or old sealant that could interfere with a proper seal or damage the valve.
  3. Siġillant tal-Ħjut: Apply an appropriate thread sealant (e.g., PTFE tape or pipe dope) to the male pipe threads. Do not apply sealant to the first thread to prevent it from entering the valve and potentially causing blockages.
  4. Orjentazzjoni tal-valv: Install the valve in the correct flow direction if indicated (though 2-way ball valves are generally bi-directional). Ensure there is sufficient space for operation and maintenance.
  5. Issikkar: Thread the valve onto the pipe ends. Use a wrench on the valve body, not the handle or actuator mounting pad, to tighten connections. Avoid over-tightening, which can damage the valve or threads.
  6. Iċċekkja t-Tnixxija: After installation, slowly repressurize the system and carefully check all connections for leaks.

5. Istruzzjonijiet Operattivi

The Belimo B213 ball valve is designed for simple quarter-turn operation.

For precise flow control, the valve can be partially opened or closed, though it is primarily designed for on/off applications.

6. Manutenzjoni

The Belimo B213 ball valve is generally considered low-maintenance. Regular inspection is recommended to ensure continued reliable operation.

For internal maintenance or seal replacement, it is advisable to consult a qualified professional or Belimo technical support.

7 Issolvi l-problemi

This section addresses common issues that may arise during the use of the Belimo B213 ball valve.

ProblemaKawża PossibbliSoluzzjoni
Valve leaks at connectionsImproperly tightened connections, damaged threads, insufficient thread sealant.Depressurize system. Re-tighten connections. If leak persists, disassemble, inspect threads, reapply sealant, and reassemble. Replace if threads are damaged.
Valve leaks through the stemDamaged stem packing.Depressurize system. Tighten packing nut slightly (if adjustable). If leak persists, stem packing may need replacement by a qualified technician.
Valve difficult to operate (stiff)Debris in the ball/seat area, lack of lubrication (rare for ball valves), internal damage.Depressurize system. Cycle the valve a few times. If stiffness persists, the valve may need to be removed and inspected for internal debris or damage. Replacement may be necessary.
Valve not fully opening/closingObstruction, actuator malfunction (if present), internal damage.Depressurize system. Inspect for external obstructions. If using an actuator, check its power and function. Internal inspection by a professional may be required.

If troubleshooting steps do not resolve the issue, contact Belimo technical support or a qualified service professional.

8. Speċifikazzjonijiet

AttributDettall
BrandBelimo
MudellB213
Tip ta' ValvValv tal-Ball 2-Way
Daqs tal-Konnessjoni1/2 pulzier
Trim MaterialStainless Steel
Flow Coefficient (Cv)4.7
ASINB008HOSBDO
UPC645220680139
ManifatturBelimo
Dimensjonijiet tal-Pakkett27.6 x 12 x 12 pulzier; 3 Liri
Data L-Ewwel Disponibbli11 ta’ Diċembru 2014

9. Garanzija u Appoġġ

For detailed information regarding the warranty terms and conditions for your Belimo B213 ball valve, please refer to the official Belimo warranty statement provided with your purchase or visit the official Belimo website. For technical assistance, product inquiries, or to locate authorized service centers, please contact Belimo customer support directly.

Contact information can typically be found on the Belimo webis-sit jew fuq l-imballaġġ tal-prodott.

Dokumenti Relatati - B213

Preview Valv Globu 3-Way Belimo G320 b'Attwatur LVKX24-MFT: Speċifikazzjonijiet Tekniċi u Gwida għall-Installazzjoni
Speċifikazzjonijiet tekniċi dettaljati, dimensjonijiet, informazzjoni dwar l-applikazzjoni, u dijagrammi tal-wajers għall-valv globu bi 3 direzzjonijiet Belimo G320 u l-attwatur modulanti fail-safe LVKX24-MFT. Jinkludi noti ta' installazzjoni u dejta tal-prodott.
Preview Gwida għall-Applikazzjoni tal-Belimo Energy Valve™: Ottimizza s-Sistemi HVAC
Comprehensive application guide for the Belimo Energy Valve™, detailing its advanced features, HVAC applications, energy efficiency benefits, and IoT integration for smart building management. Learn about pressure independence, flow control, power control, and Delta T management for optimized HVAC systems.
Preview Dejta Teknika tal-Valv Butterfly BELIMO F680HD u l-Attwatur GRX24-MFT-T N4
Folji tad-dejta teknika komprensivi għall-Valv Butterfly BELIMO F680HD bit-Tipi ta' Lug u l-Attwatur GRX24-MFT-T N4, inklużi speċifikazzjonijiet, dimensjonijiet, materjali, aċċessorji, noti ta' installazzjoni, u dijagrammi tal-wajers.
Preview Skeda Teknika tad-Data tal-Valv tal-Enerġija Belimo EV..R2+BAC
Detailed technical specifications, features, and installation guidelines for the Belimo EV..R2+BAC Energy Valve. This smart control valve integrates energy metering, flow measurement, and advanced communication protocols like BACnet and Modbus for HVAC applications.
Preview Gwida tal-Prodott u Lista tal-Prezzijiet ta' Belimo 2018 għall-Ameriki - Valvijiet u Attwaturi tal-HVAC
Explore the comprehensive 2018 Product Guide and Price List from Belimo Americas, featuring innovative HVAC valves, actuators, sensors, and control solutions for building efficiency and comfort. Find detailed product specifications and pricing.
Preview Dejta Teknika tal-Konnessjoni tal-Valv Globu Universali Belimo UGVL & l-Attwatur LVKX24-MFT
Speċifikazzjonijiet tekniċi komprensivi, dimensjonijiet, u dijagrammi tal-wajers għall-Belimo UGVL Universal Globe Valve Linkage iddisinjat għall-attwaturi tas-serje LV u SV, u l-Belimo LVKX24-MFT Modulating Fail-Safe Actuator.