Introduzzjoni
The Fluke 355 digital clamp-meter is a true RMS sensing, auto-ranging multimeter designed for precise measurement of current, voltage, frequency, and resistance in various electrical testing applications. It features a robust clamp mechanism for non-contact current measurement and a comprehensive set of functions for professional use, ensuring accurate readings for both linear and non-linear loads.
Informazzjoni dwar is-Sigurtà
Always adhere to safety precautions when working with electrical equipment. This device is designed to meet IEC safety standard 61010-2-032.
- CAT IV, 600V: Suitable for measurements at the source of the low-voltage installation, such as electricity meters and primary over-current protection equipment.
- CAT III, 1,000V: Suitable for measurements within fixed installations, including switches and industrial equipment permanently connected to the fixed installation.
Ensure proper personal protective equipment (PPE) is used, and always follow local safety regulations when operating this device.
X'hemm fil-Kaxxa
Your Fluke 355 Clamp-Meter package includes the following components:
- Fluke 355 digital clamp-meter
- Sett taċ-ċomb tat-test
- Sett tas-sonda tat-test
- Sett tal-klipp tal-alligatur
- (6) Batteriji AA
- Kaxxa tal-ġarr artab
- Manwal għall-utent

Image: All components included with the Fluke 355 Clamp-Meter, neatly arranged.
Karatteristiċi tal-Prodott
- Sensing RMS Veru: Provides accurate readings for both linear and non-linear loads, regardless of waveform.
- Kejl ta' Kurrent Għoli: Measures AC and DC current up to 2,000A (1,400A AC RMS).
- Large Jaw Opening: 58mm (2.3 inches) jaw opening accommodates large or multiple conductors for non-contact current measurement.
- Voltage Kejl: Miżuri AC voltage sa 600V u DC voltage sa 1,000V.
- Frequency and Resistance: Measures frequency up to 1kHz and resistance up to 400kΩ.
- Inrush Current Function: Analyzes surge current during motor startup and other inductive loads for stable measurements.
- Filtru Low-Pass: Reduces high-frequency interference for accurate measurements of complex waveforms.
- Min/Max Function: Toggles to display lowest, highest, and average readings.
- Żamma tad-Data: Freezes the reading on the display for easy documentation in tight spaces.
- Buzzer tal-Kontinwità: Confirms electrical continuity.
- LCD retroilluminat: Improves visibility in low-light conditions, with automatic backlight shut-off.
- Mitfi Awtomatiku: Conserves battery life by automatically turning off after 20 minutes of non-use.
- Indikatur ta' Batterija Baxxa: Signals when batteries need replacement.
Setup
Installazzjoni tal-batterija
The Fluke 355 requires six 1.5V AA batteries for operation. These are typically included with your purchase.
- Sib l-għatu tal-kompartiment tal-batterija fuq wara tal-apparat.
- Uża tornavit biex tiftaħ il-qoxra.
- Insert the six AA batteries, ensuring correct polarity (+/-).
- Ibdel l-għatu tal-kompartiment tal-batterija u waħħalha.
Spezzjoni Inizjali
Before first use, inspect the clamp-meter, test leads, and accessories for any signs of damage. Do not use the device if any damage is observed.
Istruzzjonijiet Operattivi
Tixgħel/Jitfi
Turn the rotary switch to any measurement function to power on the device. Turn the rotary switch to "OFF" to power off. The device will automatically power off after 20 minutes of inactivity to conserve battery life.
Measuring AC/DC Current (Clamp Funzjoni)
- Turn the rotary switch to the "A AC+DC" position.
- Agħfas il-lieva tar-rilaxx tax-xedaq biex tiftaħ il-klaċċamp xedaq.
- Poġġi l-clamp jaws around a single conductor. Ensure the jaws are fully closed.
- Aqra l-valur attwali fuq l-LCD.

Image: The clamp jaws of the Fluke 355 securely closed around an electrical conductor for current measurement.
Vol. tal-kejltage (AC/DC)
- Connect the test leads to the appropriate input jacks (COM and V).
- Turn the rotary switch to the "V AC+DC" position.
- Qabbad il-probi tat-test madwar iċ-ċirkwit jew il-komponent li għandu jitkejjel.
- Aqra l-voltagIl-valur fuq l-LCD.
Measuring Resistance (Ω)
- Connect the test leads to the appropriate input jacks (COM and Ω).
- Dawwar is-swiċċ rotatorju għall-pożizzjoni "Ω".
- Kun żgur li ċ-ċirkwit ma jkollux l-enerġija qabel ma tkejjel ir-reżistenza.
- Qabbad il-probi tat-test mal-komponent li għandu jitkejjel.
- Aqra l-valur tar-reżistenza fuq l-LCD.
Funzjonijiet Oħra
- FIRXA: Manually select the measurement range if auto-ranging is not desired.
- ŻOMM: Agħfas biex tiffriża l-qari attwali fuq id-displej. Agħfas mill-ġdid biex tirrilaxxa.
- ŻERO: Used to zero out DC current readings or resistance readings for lead compensation.
- Hz: Measures frequency.
- INRUSH: Measures the peak current during motor startup.
- MIN MASSIMU: Toggles through minimum, maximum, and average readings captured during a measurement session.
- FILTRI: Activates a low-pass filter to reduce electrical noise for stable readings.

Immaġni: Dettaljata view of the Fluke 355 Clamp-Meter's display and control panel.
Manutenzjoni
Tindif
Naddaf il-miter casing b'reklamaramp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and dry.
Sostituzzjoni tal-batterija
When the low-battery indicator appears on the display, replace all six AA batteries promptly to ensure accurate measurements. Follow the battery installation steps outlined in the Setup section.
Ħażna
Aħżen il-klamp-meter in its soft carrying case in a dry, dust-free environment when not in use. Remove batteries if storing for extended periods to prevent leakage.
Issolvi l-problemi
If the Fluke 355 Clamp-Meter is not functioning as expected, consider the following:
- Ebda Wiri/Qawwa: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary. Ensure the rotary switch is not in the "OFF" position.
- Qari mhux eżatt: Verify that the correct measurement function is selected. Ensure test leads are properly connected and not damaged. For current measurements, ensure the clamp jaws are fully closed around a single conductor.
- Il-Buzzer tal-Kontinwità Mhux Jaħdem: Ensure the device is in the continuity measurement mode and the circuit is de-energized.
For persistent issues, refer to the official Fluke support resources or contact customer service.
Speċifikazzjonijiet
| Parametru | Valur |
|---|---|
| Maximum AC Current Input | 2,000A (1,400A RMS) |
| Maximum DC Current Input | 2,000A |
| Massimu AC VoltagInput | 600V |
| Massimu DC VoltagInput | 1,000V |
| Maximum Frequency Detected | 1kHz |
| Maximum Resistance Detected | 400kΩ |
| Klassifikazzjoni tal-Installazzjoni | CAT IV, 600V; CAT III, 1,000V |
| Standards milħuqa | IEC safety standard 61010-2-032; CE marking; CSA; Australia N10140 |
| Provvista tal-Enerġija | (6) Batteriji 1.5V AA |
| Piż | 0.814kg / 1.8lb |
| Dimensjonijiet (H x W x D) | 300 x 98 x 52mm / 12 x 3.75 x 2 pulzieri |
| Ftuħ tax-xedaq | 58mm (2.3 pulzier) |
| Auto Power Mitfi | minuti 20 |
| Wiri | LCD backlit |
| RMS Veru | Iva |
| Auto-Ranging | Iva |
| Manifattur | Korporazzjoni Fluke |
| Numru tal-Mudell | FLUKE-355 |
| UPC | 095969401203, 785577871016 |
Garanzija u Appoġġ
Fluke Corporation provides high-quality testing tools. For warranty information, technical support, or service, please visit the official Fluke websit jew ikkuntattja lid-dipartiment tas-servizz tal-konsumatur tagħhom.
Tista' ssib aktar informazzjoni u riżorsi ta' appoġġ fuq Ħanut Fluke fuq Amazon.