1. Introduzzjoni

This manual provides essential information for the safe and correct installation, operation, and maintenance of the Gewiss GW96932 Relay. This device is a 2-way (DPDT) relay designed for switching electrical circuits with a 24V DC coil and 16A contact rating. Please read these instructions thoroughly before installation and retain them for future reference.

2. Informazzjoni dwar is-Sigurtà

Electrical installations must be carried out by qualified personnel in accordance with national and local wiring regulations. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect power to the circuit before installing, servicing, or removing the relay.
  • Ivverifika li l-provvista voltagIl-klassifikazzjonijiet tal-e u tal-kurrent jaqblu mal-ispeċifikazzjonijiet tar-relay.
  • Do not operate the relay if it appears damaged.
  • Kun żgur li l-konnessjonijiet kollha huma siguri u iżolati kif suppost.
  • This relay is designed for indoor use in dry environments unless otherwise specified.

3. Prodott Aktarview

The Gewiss GW96932 is a compact electromechanical relay. It features a 24V DC coil and two sets of changeover contacts (DPDT - Double Pole Double Throw), each rated for 16A. The relay is typically mounted on a DIN rail or within an enclosure.

Gewiss GW96932 Relay front view li juri t-terminals

Figura 1: Quddiem view of the Gewiss GW96932 Relay. This image illustrates the general appearance of the relay, including its housing and visible terminal connections for the coil and contacts. The compact design is suitable for integration into control panels.

The relay's terminals are typically labeled for easy identification of the coil connections and the common (COM), normally open (NO), and normally closed (NC) contacts for each pole.

4. Installazzjoni u Setup

4.1 Immuntar

The GW96932 relay is designed for secure mounting within an electrical enclosure or on a standard DIN rail, depending on the specific model and base used. Ensure adequate ventilation around the relay to prevent overheating.

4.2 Wajers

Refer to the wiring diagram provided with the relay or on its housing for precise terminal connections. The following is a general guide:

  • Konnessjonijiet tal-Kojl: Qabbad il-kontroll tal-volum ta' 24V DCtage to the designated coil terminals. Observe polarity if indicated.
  • Konnessjonijiet ta' Kuntatt: Connect the load circuit to the appropriate contact terminals (Common, Normally Open, Normally Closed). Ensure the load current does not exceed 16A per contact.
  • Use appropriate wire gauges for the current being carried to prevent overheating.

After wiring, double-check all connections for tightness and correctness before applying power.

5. Istruzzjonijiet Operattivi

The Gewiss GW96932 relay operates by energizing its 24V DC coil. When the coil is energized, the internal contacts switch from their normally closed (NC) position to their normally open (NO) position. When the coil is de-energized, the contacts return to their original NC position.

  • Apply 24V DC to the coil terminals to activate the relay.
  • Remove 24V DC from the coil terminals to deactivate the relay.
  • The relay acts as a switch, controlling the flow of current through the connected load circuits.

6. Manutenzjoni

The Gewiss GW96932 relay is generally maintenance-free under normal operating conditions. However, periodic inspection is recommended:

  • Visually inspect the relay for any signs of physical damage, discoloration, or overheating.
  • Check all terminal connections for tightness to ensure good electrical contact.
  • Kun żgur li l-ambjent operattiv jibqa' fil-limiti speċifikati tat-temperatura u l-umdità.

Do not attempt to open or repair the relay. If the relay malfunctions, it should be replaced by a qualified technician.

7 Issolvi l-problemi

Jekk ir-relay mhux qed jaħdem kif mistenni, ikkunsidra dan li ġej:

  • Relay not activating:
    • Check if 24V DC is present at the coil terminals when activation is expected.
    • Verify coil polarity if applicable.
    • Ensure the coil terminals are securely connected.
  • Load not switching:
    • Confirm the relay coil is activating (a click sound or visual indicator if present).
    • Check continuity across the contacts when the relay is activated.
    • Ensure the load circuit is correctly wired to the NO or NC contacts as intended.
    • Verify the load current does not exceed the contact rating (16A).
  • Is-sħana żejda:
    • Ensure adequate ventilation around the relay.
    • Check if the load current exceeds the relay's contact rating.

If issues persist, consult a qualified electrician or contact Gewiss support.

8. Speċifikazzjonijiet

ParametruValur
Numru tal-MudellGW96932
BrandĠewiss
Coil Voltage24V DC
Kuntatt Konfigurazzjoni2W (DPDT - Double Pole Double Throw)
Kuntatt Klassifikazzjoni Kurrenti16A
Vol Operattivtage (Contacts)Up to 250 Volts (AC/DC, depending on load type)
KulurWhite (Farbe Weiß)
Kwantità1

9. Rimi

This product should not be disposed of with household waste. Please dispose of it in accordance with local regulations for electronic waste. Proper disposal helps prevent potential negative consequences for the environment and human health.

10. Garanzija u Appoġġ

Gewiss products are manufactured to high-quality standards. For information regarding warranty terms, technical support, or spare parts availability, please refer to the official Gewiss website or contact your local Gewiss distributor. Keep your purchase receipt as proof of purchase.

Dokumenti Relatati - GW96932

Preview GEWISS CHORUSMART CVD 4X10A DIN Rail LED Dimmer Booster - Technical Specifications
Detailed technical specifications and installation guide for the GEWISS CHORUSMART CVD 4X10A DIN rail booster, designed to extend LED dimmer control capacity.
Preview GEWISS JOINON GWJ8037 & GWJ8038 RJ45 Network Interface Installation Guide
Installation and system overview for GEWISS JOINON GWJ8037 (1PH) and GWJ8038 (3PH) RJ45 CAT. 5 F/UTP network interface modules, including wiring diagrams and system integration with solar power.
Preview GEWISS Chorusmart GW10677/GW10678 Auxiliary Axial Command Module: Installation and Technical Guide
Comprehensive guide for GEWISS Chorusmart GW10677 and GW10678 auxiliary axial command modules. Covers safety, general information, LED functions, connection examples, assembly, maintenance, and technical specifications for smart home automation.
Preview Gewiss CHORUSMART Connected Axial Dimmer Module Installation and Technical Guide
Comprehensive guide for the Gewiss CHORUSMART Connected Axial Dimmer Module (GWA1221, GWA1222), covering installation, functions, technical specifications, Zigbee connectivity, and safety information.
Preview GEWISS SMART [3] LED Lighting Fixture - Installation Guide and Warnings
Installation guide and safety warnings for the GEWISS SMART [3] LED lighting fixture. Learn about IP66/IP69 ratings, outdoor installation precautions, and electrical safety.
Preview GEWISS CHORUSMART Booster for CVD LED Dimmer 4x16A - DIN Rail Mounting
Technical specifications and installation guide for the GEWISS CHORUSMART Booster, model GW90768, designed to extend CVD LED dimmer control capacity up to 16A per channel. Suitable for DIN rail mounting and KNX systems.