YORK S1-1CB0521

YORK S1-1CB0521 Combustible Floor Base 21 (Downflow) Instruction Manual

Model: S1-1CB0521 | Brand: YORK

1. Introduzzjoni

This instruction manual provides essential information for the proper installation, operation, and maintenance of the YORK S1-1CB0521 Combustible Floor Base. This base is specifically designed to support 21-inch wide downflow furnaces, ensuring safe and compliant installation on combustible flooring surfaces. Please read this manual thoroughly before proceeding with installation or use to ensure safety and optimal performance.

2. Informazzjoni dwar is-Sigurtà

TWISSIJA: Installazzjoni, aġġustament, alterazzjoni, servizz jew manutenzjoni mhux xierqa jistgħu jikkawżaw ħsara lill-proprjetà, korriment, jew mewt. Aqra sew dawn l-istruzzjonijiet qabel ma tinstalla jew tagħmel manutenzjoni fuq dan it-tagħmir.

  • Always disconnect power to the furnace before installation or servicing.
  • Ensure all local and national building codes, as well as HVAC regulations, are followed.
  • L-installazzjoni għandha titwettaq biss minn persunal ikkwalifikat.
  • Ilbes tagħmir protettiv personali (PPE) xieraq waqt l-installazzjoni.
  • Verify that the floor base is compatible with your specific furnace model and dimensions (21-inch wide downflow furnaces).
  • Do not modify the floor base. Any alterations may compromise its structural integrity and safety.

3. Prodott Aktarview

The YORK S1-1CB0521 Combustible Floor Base provides a stable and safe foundation for downflow furnaces installed on combustible floor surfaces. Its robust construction ensures proper support and compliance with safety standards, preventing heat transfer to the combustible material below the furnace.

YORK S1-1CB0521 Combustible Floor Base, a rectangular metal frame designed to support a furnace.

Figure 1: The YORK S1-1CB0521 Combustible Floor Base. This image shows a rectangular metal frame, typically used as a support structure for HVAC units, designed to provide a safe barrier between a heat-producing appliance and a combustible floor.

4. Setup u Installazzjoni

Follow these steps for the correct installation of the YORK S1-1CB0521 Combustible Floor Base:

  1. Preparazzjoni: Ensure the installation area is clean, level, and free from obstructions. Verify that the floor surface is capable of supporting the combined weight of the furnace and the base.
  2. Spakkjar: Carefully remove the floor base from its packaging. Inspect for any shipping damage. Do not install if damaged.
  3. Pożizzjonament: Place the combustible floor base in the desired location where the downflow furnace will be installed. Ensure it is properly aligned and level.
  4. Furnace Placement: Carefully lift and position the 21-inch wide downflow furnace onto the installed floor base. Ensure the furnace sits securely and evenly on the base.
  5. Securing (if applicable): Depending on the furnace model and local codes, the furnace may need to be secured to the base or the floor. Refer to your furnace's installation manual for specific securing instructions.
  6. Ductwork and Connections: Proceed with connecting ductwork, electrical, and gas lines according to the furnace manufacturer's instructions and local codes.
  7. Spezzjoni Finali: Before operating the furnace, perform a thorough inspection to ensure all connections are secure, the base is stable, and there are no obstructions to airflow.

Note: This base is designed for downflow furnaces. Ensure your furnace configuration matches this requirement.

5. Prinċipji Operattivi

The YORK S1-1CB0521 Combustible Floor Base functions as a critical component in the safe installation of downflow furnaces on combustible surfaces. It creates an insulated air gap or barrier, preventing the direct transfer of heat from the furnace to the floor. This ensures compliance with safety regulations and reduces the risk of fire. Once installed, the base requires no active operation; its function is passive and continuous as long as the furnace is in place.

6. Manutenzjoni

The combustible floor base itself requires minimal maintenance. However, it is recommended to include it in your regular HVAC system checks:

  • Spezzjoni Annwali: During routine furnace maintenance, visually inspect the floor base for any signs of corrosion, damage, or displacement.
  • Indafa: Ensure that the area around and under the furnace, including the base, remains free of debris, dust, and flammable materials.
  • Integrità Strutturali: Verify that the base remains level and stable. Any signs of warping or structural compromise should be addressed immediately by a qualified technician.

7 Issolvi l-problemi

As a passive component, the floor base typically does not experience "trouble" in the traditional sense. Most issues would stem from improper installation or external factors.

ProblemaKawża PossibbliSoluzzjoni
Furnace not level on baseUneven floor surface; improper base placementRe-level the floor surface or adjust base shims (if applicable). Ensure base is on a stable, flat surface.
Base appears damaged or corrodedEnvironmental exposure; physical impact; ageContact a qualified HVAC technician for inspection and potential replacement. Do not operate furnace with a compromised base.
Airflow issues (if related to base)Improper sealing around base/furnace; obstructionsEnsure proper sealing between the furnace and base. Check for any debris blocking air intake/exhaust around the base.

8. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-MudellS1-1CB0521
BrandYORK
Tip ta' ProdottBażi tal-Art kombustibbli
Kompatibilità21-inch wide downflow furnaces
MaterjalGalvanized Steel (typical for such bases)
ManifatturYORK
ASINB007R7U78O
Data L-Ewwel Disponibbli8 ta’ Jannar, 2018

9. Garanzija u Appoġġ

For specific warranty information regarding the YORK S1-1CB0521 Combustible Floor Base, please refer to the documentation provided at the time of purchase or contact YORK directly. Warranty terms may vary based on region and seller.

For technical support or further inquiries, please visit the official YORK brand page on Amazon or consult a certified HVAC professional.

Dokumenti Relatati - S1-1CB0521

Preview Lista tal-Partijiet u Dijagrammi tal-Franijiet tal-Gass Naturali tas-Serje York PS9
Lista komprensiva tal-partijiet u dijagrammi tal-komponenti għall-Fran tal-Gass Naturali Orizzontali/90% Downflow tas-Serje York PS9, inklużi n-numri tal-mudelli PS9B12N060DH11A, PS9B12N080DH11A, PS9C16N080DH11A, PS9C16N100DH11A, PS9C20N100DH11A, u PS9D20N120DH11A.
Preview York DGAA & DGAH High Efficiency Gas Furnace: User, Maintenance, and Service Manual
Comprehensive guide for York DGAA and DGAH High Efficiency Sealed Combustion Gas Furnaces, covering safety, installation, operation, maintenance, troubleshooting, and parts.
Preview York TM9E Series Residential Gas Furnace Installation Manual
Comprehensive installation manual for York TM9E Series single-stage ECM residential gas furnaces. Covers safety, ductwork, gas piping, electrical, venting, start-up, and diagnostics for these high-efficiency HVAC units.
Preview Installation Instructions: York Control Packages for 2-Wire and 4-Wire Thermostats (Models 7900-6021/B, 7900A6041)
Detailed installation instructions for York 7900-6021/B and 7900A6041 control packages, covering wiring, mounting, and application for 2-wire and 4-wire thermostats in manufactured housing gas and oil furnaces. Includes safety warnings and compatibility information.
Preview Lista tal-Partijiet tal-Franijiet tal-Gass Naturali Orizzontali/90% Downflow tas-Serje York PS9
Lista komprensiva tal-partijiet u dijagrammi għall-Fran tal-Gass Naturali Orizzontali/90% Downflow tas-Serje York PS9, inklużi n-numri tal-mudelli PS9B12N060DH11A, PS9B12N080DH11A, PS9C16N080DH11A, PS9C16N100DH11A, PS9C20N100DH11A, u PS9D20N120DH11A. Jinkludi l-identifikazzjoni tal-komponenti u n-numri tal-partijiet.
Preview YORK YP8C Series 80% Modulating Variable Speed ECM Natural Gas Furnace Parts List
This document provides a detailed parts list and component identification for YORK YP8C Series 80% Modulating Variable Speed (ECM) Multi-Position 33-inch Natural Gas Furnaces, including Low NOx models (Style A). It covers various configurations and lists part numbers for motors, electrical components, fabricated parts, and miscellaneous items, aiding in service and replacement.