Extech VB300

Manwal tal-Utent tar-Reġistratur tad-Data tal-Vibrazzjoni Extech VB300

Model: VB300 | Brand: Extech

1. Prodott Aktarview

The Extech VB300 is a compact and robust 3-axis G-Force datalogger. It is engineered to record and timestamp shock and vibration (acceleration) events across its ±18g measurement range. This device is essential for monitoring and documenting environmental conditions during storage, transport, or operational use, providing critical data on g-force and peak accelerations.

Extech VB300 3-Axis G-Force USB Datalogger Meter

Figure 1.1: The Extech VB300 3-Axis G-Force USB Datalogger Meter, a compact device for recording vibration data.

Karatteristiċi ewlenin:

  • Built-in 3-axis accelerometers for precise shock event recording.
  • Real-time FFT Frequency and Time-Domain Vibration Analysis capabilities.
  • Designed to record storage, transport, or operational data over extended periods.
  • Software allows selectable X-, Y-, Z-axis or any combination for data logging.
  • Capable of datalogging up to 85,764 peak acceleration samples.

2. Setup

Before using your Extech VB300, ensure proper setup by installing the battery, installing the necessary software, and securely mounting the device.

2.1 Installazzjoni tal-batterija

The VB300 requires one 3.6V Lithium battery (included). Carefully open the battery compartment, insert the battery observing polarity, and close the compartment securely.

2.2 Installazzjoni tas-Softwer

The device comes with Windows-compatible analysis software. Insert the software CD into your computer's drive and follow the on-screen instructions for installation. If the CD is not available, the software can typically be downloaded from the official Extech support websit.

2.3 Immuntar tal-Apparat

The VB300 includes a magnetized/bolt-on mounting base for versatile attachment. Choose a stable surface for mounting, ensuring the device is securely fastened to accurately capture vibration data.

Extech VB300 with its magnetized/bolt-on mounting base

Figure 2.1: The Extech VB300 shown with its versatile magnetized/bolt-on mounting base.

Extech VB300 mounted on an industrial motor for vibration monitoring

Figure 2.2: The Extech VB300 securely mounted on an industrial motor, demonstrating a typical application for vibration monitoring.

Contents of the Extech VB300 package including the datalogger, mounting base, USB cable, and software CDs

Figure 2.3: The complete package contents for the Extech VB300, showing the datalogger, mounting base, USB cable, and software installation discs.

3. Istruzzjonijiet Operattivi

The Extech VB300 is designed for straightforward operation to log vibration data. Follow these steps to begin recording and retrieving data.

3.1 Tibda r-Reġistrazzjoni tad-Data

  • Ensure the VB300 is securely mounted in the desired location.
  • Press the 'Record' button on the device to initiate data logging. The 'Record' LED indicator will illuminate or flash to confirm recording has started.
  • The device will now continuously record 3-axis g-force data based on the configured settings.

3.2 Twaqqif tar-Reġistrazzjoni tad-Data

  • To stop recording, press the 'Record' button again. The 'Record' LED will turn off.
  • Alternatively, logging will automatically stop once the internal memory is full or the battery is depleted.

3.3 Data Retrieval and Analysis

  • Connect the VB300 to your computer using the provided USB cable.
  • Launch the Extech analysis software on your computer.
  • The software will detect the connected device and allow you to download the logged data.
  • Uża s-softwer biex view, analyze, and export the vibration data, including FFT Frequency and Time-Domain analysis.

4. Manutenzjoni

Proper maintenance ensures the longevity and accuracy of your Extech VB300.

4.1 Tindif

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Keep the USB port free from dust and debris.

4.2 Sostituzzjoni tal-batterija

When the battery indicator shows low power, replace the 3.6V Lithium battery promptly to ensure continuous operation and data integrity. Refer to section 2.1 for battery installation steps.

4.3 Ħażna

Store the VB300 in a cool, dry place away from direct sunlight and extreme temperatures when not in use for extended periods.

5 Issolvi l-problemi

This section addresses common issues you might encounter with your Extech VB300.

5.1 L-Apparat Mhux Jirrispondi

  • Iċċekkja l-livell tal-batterija u ibdel jekk meħtieġ.
  • Ensure the device is properly connected to the USB port if attempting data transfer.
  • Try restarting your computer and reconnecting the device.

5.2 Data Not Logging

  • Verify that the 'Record' button was pressed and the corresponding LED is active.
  • Check if the device's memory is full. Download data to clear memory if needed.
  • Kun żgur li l-batterija għandha ċarġ suffiċjenti.

5.3 Software Not Recognizing Device

  • Confirm that the Extech analysis software is correctly installed.
  • Ipprova port USB differenti fuq il-kompjuter tiegħek.
  • Kun żgur li l-kejbil tal-USB ma jkunx bil-ħsara.
  • Check for updated drivers or software versions on the Extech websit.

6. Speċifikazzjonijiet

Detailed technical specifications for the Extech VB300 Vibration Data Logger.

SpeċifikazzjoniValur
Numru tal-MudellVB300
Dimensjonijiet tal-Prodott3.7 x 1.1 x 0.8 pulzieri
Piż tal-oġġett1.06 uqija
Sors tal-EnerġijaMħaddma bil-batterija
Tip ta 'batterija1 batterija tal-Lithium Metal (inkluża)
Teknoloġija tal-KonnettivitàCable USB
Apparati KompatibbliDesktop, Laptop
ManifatturExtech
Data L-Ewwel Disponibbli26 ta’ Mejju, 2012

7. Garanzija u Appoġġ

Extech provides support for its products. For specific warranty information, please refer to the documentation included with your purchase or visit the official Extech websit.

7.1 Pjanijiet ta' Protezzjoni

Extended protection plans may be available for your Extech VB300, offering additional coverage beyond the standard manufacturer's warranty. These plans can be purchased separately and typically cover repairs or replacements for a specified duration.

7.2 Appoġġ għall-Klijent

For technical assistance, troubleshooting, or inquiries regarding your Extech VB300, please contact Extech customer support. Contact details can usually be found on the Extech webis-sit jew fl-imballaġġ tal-prodott tiegħek.

Dokumenti Relatati - VB300

Preview Extech Comprehensive Catalog: Environmental Meters, Anemometers, and Test Equipment
Explore Extech's extensive range of high-quality environmental meters, thermo-anemometers, gas detectors, water quality testers, sound meters, light meters, and other precision test and measurement instruments designed for industrial, HVAC/R, and professional applications.
Preview Manwal tal-Utent tad-Datalogger tat-Temperatura Extech TH10
Manwal tal-utent għall-Extech TH10 Temperature Datalogger, li jiddeskrivi l-karatteristiċi, l-operat, l-ispeċifikazzjonijiet, is-sostituzzjoni tal-batterija, u l-interfaċċja tas-softwer tiegħu. Jinkludi informazzjoni dwar il-garanzija u l-appoġġ għall-klijenti.
Preview EXTECH 407760 Manwal għall-Utent tal-Miter tal-Livell tal-Ħsejjes USB Datalogger
Manwal tal-utent għall-EXTECH 407760 Sound Level Meter USB Datalogger. Dan id-dokument jipprovdi informazzjoni essenzjali dwar l-introduzzjoni, it-tħaddim, u l-proċeduri ta' sostituzzjoni tal-batterija tal-apparat.
Preview Manwal tal-Utent tal-EXTECH 45170 4-f'1 Meter tal-Umdità, Temperatura, Fluss tal-Arja, u Dawl
Manwal tal-utent għall-EXTECH 45170, miter 4 f'1 li jkejjel l-umdità, it-temperatura, il-fluss tal-arja, u d-dawl. Jinkludi informazzjoni dwar it-tħaddim, l-ispeċifikazzjonijiet, u l-garanzija.
Preview Gwida ta' Għajnuna tas-Software ta' Datalogger tat-Temperatura Extech TH10
Gwida ta' Għajnuna għas-Softwer tad-Datalogger tat-Temperatura Extech TH10: Tgħallem kif tinstalla, tikkonfigura, u tħaddem is-softwer tad-datalogger tat-temperatura Extech TH10 għal monitoraġġ effiċjenti tat-temperatura u analiżi tad-dejta.
Preview EXTECH RHT20 Humidity & Temperature Datalogger User Manual
User manual for the EXTECH RHT20 Humidity & Temperature Datalogger, covering meter description, operation, software installation, maintenance, specifications, and warranty information.