TEMPCO Type K HD

Manwal tal-Istruzzjonijiet tat-Termokoppja tal-Kalamita HD tat-Tip K TEMPCO

Model: Type K HD | Brand: TEMPCO

1. Introduzzjoni

This manual provides comprehensive instructions for the proper installation, operation, and maintenance of your TEMPCO Type K HD Magnet Thermocouple. This device is engineered for accurate and reliable temperature measurement in various industrial applications, utilizing a magnetic attachment for convenient surface temperature sensing.

2. Prodott Aktarview

The TEMPCO Type K HD Magnet Thermocouple is a robust temperature sensing device. It features a spring-loaded thermocouple element attached to a 6-pole magnet, ensuring consistent contact with ferromagnetic surfaces for precise temperature readings. The thermocouple utilizes Type K insulation (PTFE) and comes with a 12-foot lead length, terminating in fork terminals for easy connection.

TEMPCO Type K HD Magnet Thermocouple

Figura 1: TEMPCO Type K HD Magnet Thermocouple. This image displays the complete thermocouple assembly, including the magnetic probe head, the braided lead wire, and the fork terminal connectors.

Karatteristiċi ewlenin:

  • Tip ta' termokoppja: K
  • Insulazzjoni: PTFE
  • Tul taċ-ċomb: 12-il pied (144 pulzier)
  • Error Accuracy: +/-2.2 °C, +/-0.75 %
  • Limitu tat-Temperatura: 400 °F
  • Thermocouple Element: 20 AWG
  • Kostruzzjoni: Spring-loaded thermocouple attached to a 6-pole magnet
  • Tul tas-Sonda: 1.25 pulzieri
  • Materjal: 304 Stainless Steel
  • Grounded / Ungrounded: Art
  • Tip ta' Konnettur: Terminal tal-furketta

3. Informazzjoni dwar is-Sigurtà

Adherence to safety guidelines is crucial for preventing injury and equipment damage. Please read and understand all safety instructions before installing or operating the thermocouple.

  • Always disconnect power to the measurement system before making any electrical connections or disconnections.
  • Do not exceed the specified temperature limit of 400 °F (204 °C). Exceeding this limit can damage the thermocouple and lead to inaccurate readings.
  • Ensure proper electrical polarity when connecting the thermocouple to a temperature controller or data acquisition system. Incorrect polarity will result in inaccurate readings.
  • Avoid placing the thermocouple in direct contact with live electrical circuits unless specifically designed and rated for such applications.
  • Handle the lead wire carefully to prevent damage to the insulation or internal conductors.
  • Consult local electrical codes and safety regulations for proper installation and operation.

4. Setup

4.1 Disimballaġġ

Carefully remove the thermocouple from its packaging. Inspect the device for any visible damage that may have occurred during shipping. If any damage is observed, do not proceed with installation and contact your supplier.

4.2 Installazzjoni

Follow these steps to properly install your TEMPCO Type K HD Magnet Thermocouple:

  1. Prepare the Connection Point: Ensure the temperature controller or data acquisition system is powered off and ready to receive a Type K thermocouple input.
  2. Connect the Fork Terminals: Connect the red fork terminal to the positive (+) input and the white fork terminal to the negative (-) input of your temperature monitoring device. Type K thermocouples use specific color codes for polarity.
  3. Select Measurement Surface: Identify a clean, ferromagnetic surface where temperature measurement is required. Ensure the surface is free from debris, rust, or paint that could impede good thermal contact.
  4. Attach the Magnet: Firmly place the magnetic probe head onto the selected ferromagnetic surface. The 6-pole magnet and spring-loaded design will ensure optimal contact for accurate temperature transfer.
  5. Secure the Lead Wire: Route the 12-foot lead wire away from potential hazards, excessive heat, or moving parts. Use appropriate cable management techniques to prevent strain or damage to the wire.

5. Istruzzjonijiet Operattivi

Once installed, operating the TEMPCO Type K HD Magnet Thermocouple is straightforward:

  1. Ivverifika l-Anness: Ensure the magnetic probe is securely attached to the measurement surface and that the lead wire connections are firm.
  2. Sistema ta' Mixgħul: Power on your temperature controller or data acquisition system.
  3. Qari tal-Monitoraġġ: Observe the temperature readings on your connected device. Allow a few moments for the thermocouple to stabilize and provide an accurate reading of the surface temperature.
  4. Aġġusta l-Pożizzjonament (jekk meħtieġ): If readings appear inconsistent or inaccurate, temporarily power off your system, re-evaluate the probe's placement, and ensure optimal surface contact.

6. Manutenzjoni

Regular maintenance ensures the longevity and accuracy of your thermocouple.

  • Inspect Lead Wire: Periodically inspect the entire length of the lead wire for any signs of fraying, cuts, or damage to the PTFE insulation. Replace the thermocouple if significant damage is found.
  • Clean Magnet Surface: Keep the magnetic probe head clean and free of dust, grease, or metallic particles. A clean contact surface is essential for accurate temperature transfer. Use a soft, dry cloth for cleaning.
  • Iċċekkja l-Konnessjonijiet: Ensure the fork terminals remain securely fastened to your monitoring device. Loose connections can lead to intermittent or inaccurate readings.
  • Evita liwi Eċċessiv: Do not bend the thermocouple probe or lead wire sharply, as this can damage the internal conductors or insulation.

7 Issolvi l-problemi

If you encounter issues with your thermocouple, refer to the following troubleshooting guide:

ProblemaKawża PossibbliSoluzzjoni
No temperature reading or 'Open Circuit' errorLoose or incorrect wiring; Damaged lead wire; Faulty thermocouple element.Check all connections for tightness and correct polarity (red to +, white to -). Inspect the lead wire for visible damage. If damage is present, replace the thermocouple.
Qari mhux preċiż jew inkonsistentiPoor contact with the measurement surface; Incorrect thermocouple type selected on monitoring device; Electromagnetic interference (EMI); Exceeding temperature limits.Ensure the magnet is firmly attached to a clean, flat ferromagnetic surface. Verify that your monitoring device is configured for a Type K thermocouple. Route lead wires away from power cables or sources of EMI. Confirm the measured temperature is within the 400 °F limit.
Readings are reversed (e.g., temperature decreases when it should increase)Incorrect polarity of connections.Reverse the connections of the red and white fork terminals at your monitoring device.

8. Speċifikazzjonijiet Tekniċi

Detailed specifications for the TEMPCO Type K HD Magnet Thermocouple:

SpeċifikazzjoniValur
Tip ta 'TermokoppjaK
InsulazzjoniPTFE
Tul taċ-ċomb12-il pied (144 pulzier)
Error Accuracy+/-2.2 °C, +/-0.75 %
Limitu tat-Temperatura400 °F (204 °C)
Thermocouple Element20 AWG
KostruzzjoniSpring-loaded thermocouple attached to 6-pole Magnet
Tul tas-Sonda1.25 pulzieri
Materjal304 Stainless Steel
Grounded / UngroundedArt
Plug or Connector TypeTerminal tal-furketta
Dimensjonijiet tal-Prodott (L x W x H)10 x 7 x 1.5 pulzieri
ManifatturTempco Electric Heater Corp
ASINB0078RSFRI
UPC094705296110

9. Kuntatt u Appoġġ

For technical assistance, warranty information, or further support regarding your TEMPCO Type K HD Magnet Thermocouple, please contact TEMPCO customer service through their official website or designated support channels. Provide your model number (Type K HD) and ASIN (B0078RSFRI) when seeking assistance.

Dokumenti Relatati - Type K HD

Preview Proster PST095 Termometru Diġitali Manwal ta 'Istruzzjoni
Manwal tal-utent għat-termometru diġitali b'żewġ kanali Proster PST095, li jagħti dettalji dwar il-karatteristiċi, l-operat, l-ispeċifikazzjonijiet u t-twissijiet ta' sigurtà tiegħu għal diversi tipi ta' termokoppji.
Preview Manwal tal-Utent tat-Termometru tat-Termokoppja TASI TA612ABC
Dan il-manwal tal-utent jipprovdi struzzjonijiet dettaljati għat-termometru tat-termokoppja b'input doppju TASI TA612ABC, u jenfasizza l-kapaċitajiet ta' kejl ta' preċiżjoni għolja tiegħu għal termokoppji tat-tip K u J.
Preview Istruzzjonijiet għall-Operazzjoni tat-Termometru tat-Termokoppja Wahl TM-500
Istruzzjonijiet komprensivi dwar it-tħaddim u l-ispeċifikazzjonijiet għat-termometru diġitali tat-termokoppja Wahl TM-500, li jkopru l-karatteristiċi, il-modi, il-funzjonijiet u d-dettalji tekniċi tiegħu għal kejl preċiż tat-temperatura.
Preview Gwida għall-Bidu Mgħaġġel tat-Termometru Diġitali Mastech MS6514
Gwida ta' bidu rapidu għat-Termometru Diġitali Mastech MS6514, li tkopri s-setup, it-tħaddim, u l-ispeċifikazzjonijiet għat-termokoppji tat-tip K, J, T, E, N, R, S.
Preview Reġistratur tad-Data tat-Termokoppja EL-USB-TC b'Interfaċċja USB - Lascar Electronics
Dettaljat fuqview of the Lascar EL-USB-TC thermocouple data logger, featuring temperature measurement ranges for J, K, and T types, USB interface, programmable alarms, and LED status indicators. Includes specifications, software details, and product range comparison.
Preview Termometru tal-Leġjonella RS PRO b'Tajmer Integrat - Mudell 204-8413
User manual and specifications for the RS PRO Legionella Thermometer (Model 204-8413). Features microprocessor control, integral 1 & 2 minute timers, °C/°F scales, and T/K thermocouple compatibility for accurate temperature checks in legionella applications. Includes operating instructions, troubleshooting, and technical specifications.