1. Introduzzjoni
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Eldom 72326NMP 15L Hot Water Storage Heater. Please read these instructions carefully before using the appliance and retain them for future reference.
The Eldom 72326NMP is a pressure-resistant hot water storage tank designed for over-table installation. It features a steel container with high-performance enameling and additional anti-corrosion anode protection. A temperature controller allows for stepless adjustment of the water temperature.

Stampa 1: Quddiem view of the Eldom 72326NMP 15L Hot Water Storage Heater. The unit is white with the Eldom logo prominently displayed. A control knob for temperature adjustment and a red power switch are visible at the bottom.
2. Istruzzjonijiet Importanti dwar is-Sigurtà
Failure to follow these safety instructions may result in electric shock, fire, or serious injury. Keep this manual in a safe place for future reference.
- Aqra l-istruzzjonijiet kollha qabel l-installazzjoni u l-użu.
- Installation and maintenance must be performed by a qualified technician in accordance with local regulations and this manual.
- Tiżgura l-provvista tal-enerġija voltage jaqbel mat-tikketta tal-klassifikazzjoni fuq l-apparat (230V/50Hz).
- Tħaddimx il-water heater jekk il-korda tal-enerġija jew il-plagg ikunu bil-ħsara.
- Tgħaddix l-apparat fl-ilma jew likwidi oħra.
- Dan l-apparat mhuwiex maħsub għall-użu minn persuni (inklużi tfal) b’kapaċitajiet fiżiċi, sensorji jew mentali mnaqqsa, jew nuqqas ta’ esperjenza u għarfien, sakemm ma jkunux ingħataw superviżjoni jew struzzjoni dwar l-użu tal-apparat minn persuna responsabbli għas-sigurtà tagħhom. .
- It-tfal għandhom ikunu sorveljati biex jiżguraw li ma jilagħbux bl-apparat.
- The water heater must be properly grounded.
- Tibblokkax il-valv ta 'ħelsien tal-pressjoni.
- Before any maintenance or cleaning, always disconnect the appliance from the power supply.
- The appliance must be installed in an area where it is protected from freezing temperatures.
3. Kontenut tal-Pakkett
Jekk jogħġbok iċċekkja l-pakkett għall-oġġetti li ġejjin:
- Eldom 72326NMP Hot Water Storage Heater
- Inlet Valve (Combi Check Valve)
- Manwal għall-Utent
4. Speċifikazzjonijiet Tekniċi
| Karatteristika | Speċifikazzjoni |
|---|---|
| Mudell | 72326NMP |
| Brand | Eldom |
| Qawwa Rated | 2000 W |
| Vol ikklassifikattage | 230V/50Hz |
| Kapaċità | 15 Litri |
| Pressjoni Rated | 0.8 MPa (8 bar) |
| Konnessjoni tal-Ilma | 1/2 pulzier |
| Konnessjoni tal-Enerġija | Kejbil bil-plagg |
| Klassi ta' Protezzjoni | IPX1 |
| Dimensjonijiet (H x W x D) | 520 x 285 x 288 mm |
| Piż | 9.6 kg |
| Warm-up Time (12°C to 65°C) | Madwar 27 minuta |
| Materjal | Alloy Steel (container) |
| Karatteristiċi Speċjali | Pressure-resistant, integrated check valve, anti-corrosion anode, stepless temperature control |
| Klassi tal-Effiċjenza tal-Enerġija | B |
| Konsum Annwali tal-Enerġija | 517 kWh/annum (EU Regulation 812/2013) |

Stampa 2: EU Energy Label for the Eldom 72326NMP water heater, showing an energy efficiency class of B and an annual energy consumption of 517 kWh.

Stampa 3: Product data sheet for the Eldom 72326NMP water heater, detailing technical specifications such as power, voltage, capacity, dimensions, and energy efficiency.
5. Installazzjoni
Installation should only be carried out by a qualified professional. Ensure all local plumbing and electrical codes are met.
5.1 Immuntar tal-Ħiter
- The heater is designed for over-table (under-sink) installation.
- Choose a suitable location that can support the weight of the heater when full (approx. 15L water + 9.6kg unit = ~25kg).
- Ensure adequate clearance around the unit for ventilation and maintenance.
5.2 Konnessjoni tal-Ilma
The water heater requires a 1/2 inch cold and hot water connection.
- Itfi l-provvista tal-ilma prinċipali.
- Connect the cold water inlet (marked blue) to the cold water supply line.
- Install the supplied combi check valve on the cold water inlet. This valve prevents backflow and manages pressure.
- Connect the hot water outlet (marked red) to the hot water faucet.
- Kun żgur li l-konnessjonijiet kollha huma ssikkati u mingħajr tnixxija.
- Open the main water supply and allow the tank to fill completely. Open a hot water tap to release air from the system until water flows steadily.

Stampa 4: Diagram illustrating the water connection for the Eldom 72326NMP water heater. It shows the cold water inlet, hot water outlet, and the placement of the shut-off valve, pressure reducing valve (if needed), and the combined check valve.
5.3 Konnessjoni Elettrika
- The appliance comes with a power cable and plug.
- Connect the plug to a properly grounded 230V/50Hz electrical outlet.
- Tużax estensjoni jew adapters.
6. Operazzjoni
6.1 Start-up Inizjali
- Ensure the water heater is completely filled with water (as per installation step 5.2).
- Ipplaggja l-korda tad-dawl fl-iżbokk elettriku.
- Turn on the power switch on the front of the unit. An indicator light should illuminate.
6.2 Aġġustament tat-Temperatura
- Use the temperature control knob on the front panel to set the desired water temperature.
- The temperature can be adjusted steplessly.
- Allow time for the water to heat up. The warm-up time from 12°C to 65°C is approximately 27 minutes.
7. Manutenzjoni
Manutenzjoni regolari tiżgura l-lonġevità u t-tħaddim effiċjenti tal-water heater tiegħek. Dejjem skonnettja l-provvista tal-enerġija qabel ma tagħmel kwalunkwe manutenzjoni.
7.1 Tindif
- Naddaf il-barra tal-water heater b'ċarruta ratba u driegħ.amp drapp. Tużax tindif jew solventi li joborxu.
- Periodically check the pressure relief valve for any blockages or leaks.
7.2 Anode Rod Inspection
The water heater is equipped with an anti-corrosion anode. This anode should be inspected and replaced periodically by a qualified technician, typically every 1-2 years, depending on water quality.
7.3 Tneħħija tal-Ġebla
In areas with hard water, limescale can build up inside the tank and on the heating element, reducing efficiency. Descaling should be performed by a qualified technician as needed.
8 Issolvi l-problemi
Qabel ma tikkuntattja l-appoġġ għall-klijenti, jekk jogħġbok irreferi għat-tabella li ġejja għal kwistjonijiet komuni u s-soluzzjonijiet tagħhom.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-ebda ilma sħun | No power; thermostat set too low; heating element failure. | Check power connection and switch; adjust thermostat; contact service for element replacement. |
| Ilma mhux sħun biżżejjed | Thermostat set too low; excessive hot water usage; limescale buildup. | Increase thermostat setting; allow more time for reheating; consider descaling. |
| Ilma inixxi | Konnessjonijiet laxki; valv ta' skariku tal-pressjoni difettuż; korrużjoni tat-tank. | Tighten connections; inspect/replace pressure relief valve; contact service for tank issues. |
| Ħsejjes mhux tas-soltu | Akkumulazzjoni ta' sediment fit-tank. | Consider descaling by a qualified technician. |
9. Garanzija u Appoġġ
Your Eldom 72326NMP Hot Water Storage Heater is covered by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions.
For technical assistance, spare parts, or warranty claims, please contact your retailer or the authorized Eldom service center in your region. Ensure you have your model number (72326NMP) and proof of purchase available when contacting support.