1. Prodott Aktarview
The Red Lion RL-SPRK100 is a 1 HP sprinkler pump designed for residential and light commercial lawn and turf sprinkling systems. It features a rugged cast iron casing and a high-efficiency thermoplastic impeller and diffuser. This pump is engineered for reliable performance and ease of use.

Image 1.1: The Red Lion RL-SPRK100 Sprinkler Pump, showcasing its red cast iron housing.
Karatteristiċi ewlenin:
- Kostruzzjoni Durabbli: Features a rugged cast iron pump housing and a glass-filled thermoplastic impeller, suitable for various water sources including well water and lake water.
- Doppju Voltage Motor: Operates on either 115 Volts or 230 Volts. The pump is factory-set to 230 Volts but can be easily reconfigured to 115 Volts. It is crucial to match the pump's voltage setting to the power source voltage għal tħaddim tajjeb.
- Self-Priming Capability: Requires only a one-time initial prime. No additional priming is necessary after the initial fill, simplifying setup.
- Prestazzjoni Għolja: Delivers up to 63 Gallons Per Minute (GPM) at 10 PSI and 38 GPM at 30 PSI. Capable of supporting up to 12 sprinkler heads with 1/2-inch fittings or 6 sprinkler heads with 3/4-inch fittings per zone.
- Konnessjonijiet Standard: Equipped with a 2-inch Female NPT threaded intake and a 1.5-inch Female NPT threaded discharge.

Image 1.2: Diagram highlighting key features of the pump, including the 2-inch FNPT intake, 1-1/2-inch FNPT discharge, cast iron casing, capacitor start, and thermally protected motor.
2. Setup u Installazzjoni
Proper installation is essential for the safe and efficient operation of your Red Lion RL-SPRK100 Sprinkler Pump. Refer to the complete installation manual included with your pump for detailed instructions and safety warnings.
2.1 Titjiratage Konfigurazzjoni
The pump motor is factory-set to 230 Volts. If your power supply is 115 Volts, you must adjust the motor's voltage setting before operation. Failure to match the pump's voltage to the source voltage will prevent the pump from performing to specifications and may cause damage.

Image 2.1: Instructions for setting the dual voltage motor. The pump is factory preset to 230V. To switch to 115V, insert a flat screwdriver into the black voltage change indicator and twist counter-clockwise.
2.2 Priming tal-Pompa
The RL-SPRK100 is a self-priming pump, meaning it only requires an initial prime. After the initial fill, no additional priming is typically required. Follow these general steps for initial priming:
- Kun żgur li l-konnessjonijiet kollha tal-plumbing huma sikuri u mingħajr tnixxija.
- Remove the priming plug (usually located on top of the pump casing).
- Imla l-pompa casinImlaħlaħ kompletament bl-ilma sakemm ifur.
- Replace and tighten the priming plug.
- Open any discharge valves to allow air to escape the system.
- Start the pump. It should begin pumping water within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.

Image 2.2: The Red Lion Sprinkler Pump positioned in a lawn setting, illustrating its self-priming capability up to 25 feet after the initial prime.
3. Istruzzjonijiet Operattivi
Once properly installed and primed, the Red Lion RL-SPRK100 Sprinkler Pump is ready for operation. Ensure all connections are tight and there are no obstructions in the intake or discharge lines.
3.1 Tibda tal-Pompa
Activate the power supply to the pump. The pump will begin to draw water and build pressure. Monitor the system for any unusual noises or leaks during initial startup.

Image 3.1: The Red Lion Sprinkler Pump operating in a residential setting, drawing water from a well, lake, pond, or ditch for irrigation.
3.2 Linji Gwida dwar il-Prestazzjoni
The pump is designed to deliver consistent water flow and pressure for various sprinkler system configurations. Refer to the performance chart below for expected output based on dynamic head and flow rate.

Image 3.2: Performance curve chart for Red Lion Centrifugal Sprinkler Pumps, including the RL-SPRK100, showing Total Dynamic Head (ft) versus Capacity (US gpm).
3.3 Jingħalqu l-Pompa
To turn off the pump, deactivate the power supply. If the pump will be inactive for an extended period or during freezing temperatures, follow the maintenance guidelines for winterization.
4. Manutenzjoni
Regular maintenance ensures the longevity and optimal performance of your Red Lion RL-SPRK100 Sprinkler Pump.
4.1 Verifiki ta' Rutina
- Inspect the pump and plumbing for leaks, especially at connections.
- Check for unusual noises or vibrations during operation, which may indicate a problem.
- Ensure the pump's ventilation openings are clear of debris to prevent overheating.
4.2 Winterization
In regions subject to freezing temperatures, it is crucial to properly winterize the pump to prevent damage:
- Skonnettja l-enerġija mal-pompa.
- Drain all water from the pump casing billi tneħħi t-tapp tad-drenaġġ.
- Disconnect the intake and discharge pipes and drain them thoroughly.
- Store the pump in a dry, frost-free location if possible. If not, ensure all water is completely removed and consider using RV antifreeze in the pump casing if recommended by a professional.
5 Issolvi l-problemi
This section provides general guidance for common issues. For complex problems, consult a qualified technician or contact Red Lion customer support.
5.1 Il-Pompa Ma Tibdax
- Ebda Qawwa: Check circuit breaker or fuse. Ensure power cord is securely plugged in.
- Vol mhux korretttage Setting: Verify the pump's voltage setting matches the power supply (115V or 230V).
- Tagħbija żejda tal-Mutur: Allow the motor to cool down if the thermal overload protector has tripped. Check for obstructions in the impeller.
5.2 Pump Runs But Delivers No Water or Low Pressure
- Telf tal-Prim: Re-prime the pump as described in Section 2.2. Check for air leaks in the suction line or loose connections.
- Clogged Intake/Impeller: Inspect the intake screen and impeller for debris.
- Low Water Source: Ensure the water source level is adequate for the pump's suction lift capabilities.
- Discharge Obstruction: Check for closed valves or blockages in the discharge piping or sprinkler heads.
5.3 Storbju jew Vibrazzjoni Eċċessivi
- Arja fis-Sistema: Ensure the pump is fully primed and there are no air leaks.
- Immuntar maħlul: Check that the pump is securely mounted to a stable surface.
- Foreign Object: Turn off power and inspect the impeller for any foreign objects.
6. Speċifikazzjonijiet
Detailed technical specifications for the Red Lion RL-SPRK100 Sprinkler Pump.

Image 6.1: Technical drawing illustrating the dimensions of the SPRK Series Sprinkler Pumps, including height (A), length (B), and width (C).
| Speċifikazzjoni | Valur |
|---|---|
| Brand | Red Lion |
| Numru tal-Mudell | 97101001 |
| Horsepower | 1 HP |
| Voltage | 115/230 Volts |
| Wattage | 4848 watt |
| Rata massima tal-fluss | 63 Galluni Kull Minuta (GPM) |
| Pressjoni massima | 45 PSI |
| Għoli Massimu ta 'rfigħ | 25 Saqajn |
| Intake Thread Size | NPT femminili ta' pulzier wieħed |
| Discharge Thread Size | NPT femminili ta' pulzier wieħed |
| Materjal | Cast Iron, Thermoplastic |
| Dimensjonijiet tal-Prodott (L x W x H) | 21.85" x 11.42" x 10.2" |
| Piż tal-oġġett | 53 Liri |
| Sors tal-Enerġija | Corded Elettriku |
| Komponenti Inklużi | Pump with thermoplastic impeller |
| UPC | 010121124868, 010121001398 |
7. Garanzija u Appoġġ
7.1 Garanzija tal-Manifattur
The Red Lion RL-SPRK100 Sprinkler Pump is covered by a Garanzija ta' 2 snin mill-manifattur. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty information provided with your product packaging.
7.2 Appoġġ Tekniku
For technical assistance, troubleshooting guidance, or questions regarding your Red Lion product, please contact our support team:
- Telefon ta' Appoġġ Tekniku: 1-888-885-9254
Our staff are available to assist with troubleshooting or installation assistance.